My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS_FILE 2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4444
>
2900 - Site Mitigation Program
>
PR0540885
>
FIELD DOCUMENTS_FILE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 9:11:42 AM
Creation date
4/10/2020 8:42:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
FILE 2
RECORD_ID
PR0540885
PE
2960
FACILITY_ID
FA0023381
FACILITY_NAME
FORMER EXXON SERVICE STATION NO 73942
STREET_NUMBER
4444
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11022017
CURRENT_STATUS
01
SITE_LOCATION
4444 N PERSHING AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V, XON#7-3942 Page 2 of 2 <br /> continuous zone that provides a separation of at least 5 feel vertically between the dissolved phase benzene and the foundation of existing or potential f YES r NO <br /> building:and contain total TPH<100 mgft throughout the entire depth of the bioattenuation zone. <br /> ii.For bioattenuation zone without oxygen measurements or oxygen<4%and benzene concentration are>100 pi but<1,000 pglL,the bioattenuation <br /> zone:Is a continuous zone that provides a separation of at least 10 feet vertically between the dissolved phase benzene and the foundation of existing or r YES f NO <br /> potential building,and contain total TPH<100 mglkg throughout the entire depth of the bioattenuation zone. <br /> iii.For bioattenuation zone with oxygen z 4%and benzene concentration are<1,000 pg1,the bioattenuation zone:Is a continuous zone that provides a <br /> separation of at least 5 feet vertically between the dissolved phase benzene and the foundation of existing or potential building,and contain total TPH r YES C NO <br /> <100 mglkg throughout the entire depth of the bioattenuation zone. <br /> 2a-Scenario 4 fexa pllg]:Direct Measurement of Soil Gas Concentrations <br /> L Soil Gas Sampling Locations—No Bioattenuation Zone: <br /> -Beneath or adjacent to an existing building:Soil gas sample is collected al least 5 feel below the bottom of the building foundation. r YES r NO <br /> -Future construction:The soil gas sample shall be collected from at least 5 feet below the ground surface(bgs). r YES r NO <br /> ii.Sal Gas Sampling Locations—with Bioattenuation Zone:The criteria in Column A in the Soil Gas Criteria table(page 5 of the Policy)apply M the O <br /> following requirements for a bioattenuation zone are satisfied <br /> -Minimum of 5 feet of soil between the soil vapor measurement and the foundation of an existing or ground surface of future construction. rrYES r INC <br /> -TPH(TPHg*TPHd)is<100 mglkg(measured in at least two depths within the 5-fl zone) //YES r NO <br /> -Oxygen is z 4%measured at the bottom of the 5-R zone. r YES r NO <br /> 2b-Petroleum Vapor Intrusion to Indoor Air-A site-spec risk assessment for the vapor intrusion pathway has been prepared that demonstrates human r YES r NO <br /> health is protected to the satisfaction of the regulatory agency. <br /> 2c-Petroleum Vapor Intrusion to Indoor Air-The regulatory agency has determined petroleum vapors migrating from soil or groundwater will have no <br /> significant risk of adversely affecting human health as a result a controlling exposure through the use of mitigation measures or through the use of r YES r NO <br /> institutional or engineering controls. <br /> 3.Media Specific Criteria:Direct Contact and Outdoor Air Exposure-The site is considered low-fhreat for direct contact and outdoor airexposurs, YES <br /> dIt meets 1,2,or 3 below.-CLEAR SECTION ANSMRS <br /> Does the site meet any of he Direct Contact and Outdoor Air Exposure cdtede scenarios? R YES r NO <br /> 3.1-Maximum concentrations of petroleum constituents in soil are less than or equal to those listed in the following table(LINK I for the specked depth Or YES r NO <br /> below ground surface. <br /> Additional InWmutlon __ _ <br /> Should this case be closed in spite of NOT meeting policy criteria? r YES #/No <br /> Save in Progress <br /> LOGGED IN AS HENDERSONN CONTACT GEOTRACxER HELP <br /> https://geotracker.waterboards.ca.gov/regulators/screens/closure—Policy.asp?global_id=TO... 6/27/2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.