My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_FILE 1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4444
>
2900 - Site Mitigation Program
>
PR0540885
>
SITE INFORMATION AND CORRESPONDENCE_FILE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 9:19:48 AM
Creation date
4/10/2020 8:44:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
FILE 1
RECORD_ID
PR0540885
PE
2960
FACILITY_ID
FA0023381
FACILITY_NAME
FORMER EXXON SERVICE STATION NO 73942
STREET_NUMBER
4444
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11022017
CURRENT_STATUS
01
SITE_LOCATION
4444 N PERSHING AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
554
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r Enseco <br /> Test: 8020 LCS <br /> LCS ID: 602MO30887GH <br /> Concentration Units: ug/Kg <br /> Concentration Accuracy Precision <br /> Measured % Recovery RPD <br /> Parameter Spike LCS1 LCS2 LCS1 LCS2 Av. Limits LCS Limit <br /> Benzene 500 477 486 --§6 87 97 1.0 <br /> Toluene 500 411 490 82 98 90 79-123 18 21 <br /> _ Test: PH-GC Soil LCS <br /> LCS ID: 30356-SBMS/SBMSD <br /> Concentration Units: ug/L <br /> .. Concentration Accuracy Precision <br /> Measured % Recovery RPD <br /> Parameter Spike LCS1 LCS2 LCS1 LCS2 Av. Limits LCS Limit <br /> gasoline 100000 78000 77000 78 —7—7 17.5 81-93 1.3 24 <br /> Accuracy is measured by Percent Recovery as in: <br /> % recovery = (measured concentration) x 100 <br /> actual concentration <br /> Precision is measured using duplicate tests by Relative Percent Difference <br /> (RPD) as in: <br /> RPD = (% recovery test 1 - % recovery test 2 x 100 <br /> % recovery test 1 + % recovery test 2)/2 <br /> Control limits for accuracy (percent recovery) are based on the average, <br /> historical percent recovery +/-3 standard deviation units. Control limits <br /> for precision (relative percent difference) range from 0 (identical <br /> duplicate LCS results) to the average, historical relative percent <br /> difference + 3 standard deviation units. These control limits are updated <br /> on a quarterly basis. ' <br /> IV Analysis Results <br /> Results for Enseco Method 8020 are on the attached data sheets. <br /> Analysis by capillary GC-FID indicated the following: <br /> mg/kq (ppm) <br /> CAL I.D. TPH <br /> 30356-MB 10 <br /> -1 <10 <br /> -2 (10 <br /> -3 <10 <br /> -4 <10 <br /> '� -5 <10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.