CODES AND STANDARDS COOLER/FREEZER ALARMS CLIENT- <br /> NSF STANDARDS: COMPLY WITH APPLICABLE NATIONAL SANITATION COOLER FREEZER ALARMS AS MANUFACTURED BY: <br /> FOUNDATION (NSF) STANDARDS AND RECOMMENDED CRITERIA. PROVIDE COOLER/ <br /> FREEZER <br /> PRINCIPAL ITEM OF FOOD SERVICE EQUIPMENT WITH A NSF NATIONAL CONTROLS CORPORATION <br /> "SEAL OF APPROVAL" <br /> 1725 WESTERN DRIVEk., V <br /> ... <br /> UL LABEL: WHERE AVAILABLE, PROVIDE UL LABELS ON PRIME WEST CHICAGO, IL. 60185 <br /> CU-1 CU-2 O <br /> ELECTRICAL COMPONENTS F FOOD SERVICE (EQUIPMENT. PROVIDE <br /> „ (800) 323-2593 <br /> UL RECOGNIZED MARKING„ ON OTHER ITEMS WITH ELECTRICAL r :y.:•.. <br /> I I COMPONENTS SIGNIFYING LISTING BY UL, WHERE AVAILABLE. <br /> PROVIDE THE FOLLOWING: <br /> ROOF I ROOF HEALTH CODE: INSTALL FOOD SERVICE EQUIPMENT IN ACCORDANCE (1) DUAL KIT #TNC-TM100-KT2A <br /> WITH LOCAL HEALTH DEPARTMENT APPLICABLE. REGULATIONS. KIT INCLUDES: <br /> - - - -`- - - - - - - - - - - - " - 121 THERMOMETER UNITS <br /> - ^ - - - - - - - - 1. SHOP DRAWINGS UPON APPROVAL OF BID„ SUBMIT 3 SETS OF • 2 TEMPERATURE PROBES WITH 6'--0" WIRE <br /> L COMPLETE DETAILS, MECHANICAL AND ELECTRICAL REQUIREMENTS, • 1 TRANSFORMER <br /> AND INSTALLATION INSTRUCTIONS OF EACH ITEM. INCLUDE INFORMATION • 1 STAINLESS STEEL TWIN ENCLOSURE <br /> S L S ON ROUGHING IN DIMENSIONS, SERVICE CONNECTION REQUIREMENTS, <br /> TRAP AT RISER (TYP.) OPENINGS, DISPLAY AND LATCH DOOR MANUFACTURER'S INFORMATION, ADDITIONAL PROBE WIRE #X02-22GNO-820 <br /> S - - S - - S - COMPLETE FLOOR PLANS AND EQUIPMENT SPECIFICATIONS. <br /> INSTALLATION: <br /> 2. EQUIPMENT. <br /> NLD MEASUREMENTS TO ASSURE ,ACCURATE FIT OF FABRICATED • INSTALL THERMOMETER UNITS IN CASHIER AREA. <br /> I <br /> 3. INCLUDE WARRANTY INFORMATION ON ALL EQUIPMENT. • INSTALL TEMPERATURE PROBE IN EACH RESPECTIVE COOLER/FREEZER <br /> COMPARTMENT. SPLICE THE 6'-0" PROBE WIRE WITH ADDITIONAL <br /> L - PROBE WIRE AS REQUIRED TO RETURN TO CASHIER AREA. ARCO <br /> • COMPLETELY SEAL ANY AND ALL INTRUSIONS TO COOLER/FREEZER <br /> r I I LEGENDS - COMPARTMENTS. BP WEST COAST PRODUCTS,LLC <br /> IC_ ---S--- SUCTION .� IC. • LABEL ALL THERMOMETER UNITS PER RESPECTIVE COOLER/FREEZER <br /> _ TRAP AT RISER TYP. COMPARTMENTS. <br /> LIQUID ( ) <br /> CONDENSATE DRAIN • SET ALARM TEMPERATURE AS FOLLOWS: ��++�� V4A' r <br /> •WALK-IN COOLER: +35' F. �7' V <br /> C --C- -- C- ---- C _j NOTE: L -C - •WALK-IN FREEZER: D' F. <br /> �- ALL SUCTION LINES TO BE INSULATED • LOCATE TEMP. PROBES A MIN 2'-0" FROM WALL AND 5'-0" FROM DOOR. <br /> � m Z <br /> 1 n U <br /> 2 <br /> TRAP LEAVING REFRIGERATED ROOM TRAP LEAVING REFRIGERATED ROOM WALK-IN COOLER NOTES I.. l�� <br /> 1.0 GENERAL NOTES: 5.0 REFRIGERATION: CT�hC EN � <br /> 1.1 WALK-IN COOLER SHALL BE PREFABRICATED METAL CLAD PANELS 5.1 ALL EQUIPMENT MUST CONFORM TO CONDENSING UNITS AND UNIT <br /> BY CUSTOM COOLERS INC. OR EQUAL. DESIGNED IN MODULAR COOLERS SCHEDULE AS OUTLINED ON THIS SHEET. EQUIPMENT MUST <br /> CONCEPT TO FACILITATE ACCURATE JOB SITE ASSEMBLY. HAVE UL LISTING FOR THE APPLICATION AS SPECIFIED. 18215 72ND AVENUE SOUTH <br /> 2.0 PANEL CONSTRUCTION: 5.2 CONDENSING UNIT AS SPECIFIED SHALL HAVE THE FOLLOWING: KENT, WA 98032 <br /> 01 EVAPORATION PIPING SYSTEM (425)251-6222 <br /> 2.1 ALL PANELS SHALL BE FOAMED-IN-PLACE CLASS 1, POLYURETHANE 1. HIGH EFFICIENCY ALUMINUM FIN. COPPER TUBE CONDENSER. (425)251-8782 FAX <br /> SCALE: N/A CONSTRUCTION WITH 3 1/2" COMPOSITE: PANEL. THE "R" VALUE TO 2. COMPRESSOR CONTRACTOR. <br /> BE 30 WITH A DENSITY OF 2.2 POUNDS PER CUBIC FOOT. 3. HIGH AND LOW PRESSURE CONTROLS CML ENGINEERING, LAND PLANNING, <br /> EVAPORATOR COILS 2.2 THE PERIMETER OF ALL PANELS SHALL BE BUTT JOINT 4. WEATHER RESISTANT HOUSING WITH WEATHER-PROOF ELECTRICAL SURVEYING, ENVIRONMENTAL SERVICES <br /> CONTROL BOX. <br /> 32'-6" O.D. COOLER DEFROST FAN 5. ACCESS GUARD. <br /> FANS REFG. REFG. POWER BOX 2.3 PANELS TO BE JOINED AM ACTIO BY ENGAGING A CAM-ACTION 6. LOW AMBIENT CONTROL VALVE (CVP II) FPR FLOATING HEAD. NO. DATE REVISION DESCRIPTION <br /> BOX LOAD HEATCRAFT TYPE CHG. B.T.U. S SUPPLY TEMP. HEATER MOTOR LOCKING DEVICE. THE GAM ACTION DEVICE WILL DRAW THE SECTIONS 7. CRANKCASE HEATER. <br /> 18'- 1" 5'- 3" 8'-43" REQUIREMENTS Qom' MODEL # QTY- CFM R LBS. 1 HR. .F TOGETHER TO FORM A TIGHT SEAL. n 03/10/17 PERMIT SUBMITTAL <br /> � EACH EACH MCA MCA 8. LIQUID LINE FILTER DRIER, SIGHT GLASS AND SERVICE VALVE. <br /> lot L# 2.4 STANDARD PANEL FINISH SHALL BE 26 GAUGE STUCCO EMBOSSED 9. ELECTRIC DEFROST TIMER. <br /> CU-1 COOLER 40,034 BTU/H 4 LCA6110AB 2 1,300 404A -- 9,400 208/230/1/60 +34 7.8 2.0 GALVANIZED STEEL SKIN EXTERIOR WITH WHITE INTERIOR. 10. EXPANSION VALVES. <br /> z <br /> REACH-IN 2.5 PROVIDE 7-1/2" DOOR SILL HEIGHTS FOR GLASS DISPLAY DOORS. 11. THERMOSTAT AND SOLENOID. <br /> 9��ry CU-2 FREEZER 2,132 BTU/H 1 LCE694B6 1 335 404A -- 2,800 208/230/1/60 -15 5.7 1.2 � <br /> 2.6 INSULATION IS CLASS 1, POLYURETHANE FOAM WITH A FLAME SPREAD 5.3 EVAPORATOR COILS SPECIFIED IN EVAPORATOR COIL SCHEDULE. <br /> LESS THAN 25 AND A SMOKE DEVELOPMENT OF LESS THAN 450. 4 <br /> CONDENSING UNITS 2.7 CERTIFICATIONS: UL AND NSF APPROVED 5.4 EXPANSION VALVE SHALL BE SIZED BY UNIT COOLER MANUFACTURER <br /> s FOR PROPER REFRIGERATION. AS HEAD PRESSURE IS ALLOWED TO O <br /> _ REFG. REFG. CAPACITY MIN. MAX. 2.8 MEASUREMENTS AND CONFIGURATIONS REFER TO THIS SHEET. DROP DURING LOW AMBIENT CONDITIONS, EXPANSION VALVE NEEDS <br /> BOX LOAD HEATCRAFT SUCTION B.T.U.'S POWER DEFROST TO BE OVERSIZED TO ALLOW FLOW AT LOWER PRESSURE DIFFERENTIAL <br /> I REQUIREMENTS QTY- TYPE CHG. 1 HR. CCT. FUSE RATIO. Q <br /> �- MODEL � TEMP. R LBS. SUPPLY TIMER AMP. SIZE 3.0 COOLER WALK-IN DOOR <br /> EACH MANUFACTURED BY CUSTOM COOLERS, INC. OR EQUAL. <br /> ci 24,000 5.5 THERMOSTATS SHALL BE FURNISHED LOOSE FOR EACH SYSTEM AND Q <br /> i CU-1 COOLER 40,034 BTU/H 1 MOH03OX63C +25' 404A 20.0 ®110' AMB. 208/230/3/60 ELECTRIC 38.0 40 3.1 36" x 82" CUSTOM *ANTHONY 103NT (HEAVY DUTY) ALL GLASS SHALL BE WHITE RODGERS MODEL #1609-101 OR EQUAL, TAMPER--PROOF 8 <br /> o� PASS-THRU DOOR, SLIMLINE BLACK HANJDLE, PRO LEDs, N4 WITH PROPER TEMPERATURE RANGE, AS REQUIRED ON THIS DRAWING. Q <br /> CU-2 REACH-IN 2 132 BT 1 MQHd31 Lfi3C -20' 404A 5.5 3'281 208/230/3/60 ELECTRIC 15.0 25 THRESHOLD, CYLINDER DOOR LOCK, ALL. BLACK FINISH DOOR & FRAME, OPTIONAL MANUFACTURERS: JOHNSON OR RANCO OR EQUAL. <br /> FREEZER 0110' RMB. STAINLESS STEEL INTERIOR EXTERIOR 1 m" KICKPLATES. <br /> sr- / 5.6 SOLENOIDS SHALL BE FURNISHED LOOSE FOR EACH SYSTEM AS <br /> j �3 x 3.2 LOCATION AND SWING AS SHOWN ON THIS SHEET. ECOMMENDED BY CONDENSING UNIT MANUFACTURER. Q <br /> r 3.3 FREEZER WALK-IN DOOR 5.7)ONDENSATE PIPING SHALL BE COPPER OR PVC AND TRAPPED AFTER SEAL <br /> MANUFACTURED BY CUSTOM COOLERS, (INC. OR EQUAL. WALL PENETRATION. HEAT TAPE AND INSULATE WHERE REQUIRED <br /> TO PREVENT FREEZE UP. OV CA <br /> „ w 3.4 DOOR SHALL BE NOMINAL 3 1/2" FOAWED-IN--PLACE CLASS 1, <br /> 18'-1 D o POLYURETHANE CONSTRUCTION. 5.8 REFRIGERATION WARRANTY SHALL BE A MINIMUM OF ONE (1) YEAR PARTS L <br /> 0 <br /> FOUR (4) YEAR COMPRESSOR WARRANTY AND NINETY (90) DAYS SERVICE. ANIE BRIAN <br /> 3.5 DOOR TO BE HINGED, IN-FIT, AND HAVE 36" HIGH DIAMOND PLATE C0 < GO LWIN -7 <br /> 1'-2 " ; KICK PLATES FOR INTERIOR AND EXTERIOR. 5.9 HEAT SENSOR TO BE LOCATED 1'-2" ABOVE DOOR FRAME TO <br /> ALLOW FOR GRAPHICS INSTALLATION. , C 16865 <br /> 3.6 HINGES SHALL bE CAM-RISE WITH BRIGHT SILVER ANODIZED FINISH <br /> ON FRAME AND DOOR TRIM, TWO HINGES PER DOOR. 6.0 REFRIGERATION INSTALLATION �� REN. 8/31/17 Q <br /> 3.7 LATCH AND STRIKE TO HAVE A SATIN SURFACE CHROME FINISH WITH 6.1 EVAPORATOR COILS SHALL BE MOUNTED FROM CEILING WITH 5/16" tiS�D ARCS\ <br /> PROVISION FOR PADLOCK. LATCH TO HAVE INSIDE SAFETY RELEASE MINIMUM FASTENERS. <br /> TO PREVENT ENTRAPMENT. <br /> 6.2 CONDENSING UNITS ARE MOUNTED ON THE ROOF AND MUST BE LEVEL <br /> cp 3.8 DOOR-TO HAVE REPLACEABLE GASKETS FOR A POSITIVE SEAL AND WITH IT'S BASE ANCHORED TO PREVENT MOVEMENT. ALLOW PROPER <br /> AN ADJUSTABLE VINYL WIPER GASKET FOR SEAL AT DOOR FRAME CLEARANCE FOR AIR SUPPLY TO AND FROM UNIT AND FOR PROPER <br /> o THRESHOLD. MAINTENANCE ACCESS. <br /> 3.9 A FLUSH MOUNTED 2" DIAL THERMOMETER OF CORRECT TEMPERATURE 6.3 SUCTION LINES AT TOP OF RISER ON ROOF SHALL BE SLOPED 1" PER <br /> RANGE SHALL BE PROVIDED AT THE DOlOR. THE THERMOMETER SHALL TEN (10) FEET TO COMPRESSOR. ALL SUCTION LINES SHALL BE SIZED <br /> BE EASILY CALIBRATED. THE THERMOMETER SENSING BULB ON THE AND TRAPPED. INSULATE TO PREVENT SWEATING. <br /> INTERIOR OF THE DOOR SECTION TO HAVE PROTECTIVE COVER. <br /> 3.10 LIGHTING SHALL CONSIST OF THREE VAPOR-PROOF LIGHT FIXTURES 6.4 LIQUID LINES AND SOLENOID VALVE SHOULD BE INSTALLED IN THE <br /> TO BE FURNISHED LOSE, AND A LIGHT SWITCH WITH PILOT LIGHT LIQUID LINE JUST AHEAD OF EXPANSION VALVE IN COOLER. <br /> FLUSH MOUNTED EXTERIOR. THE WSYSTEM SHALL BE 6.5 BRAZING SHALL BE SILVER BEARING SOLDER HIGH TEMPERATURE OR <br /> APPROVED BY UNDERWRITERS LABORATORY.ORM. EQUIVALENT ALLOY SUITABLE FOR THIS APPLICATION. NO "SOFT <br /> g'-D" 3.11 PROVIDE LOCKS ON DOORS AS INDICATED ON COOLER PLAN. SOLDERS" PERMISSIBLE. NITROGEN IS TO BE PURGED THROUGH THE DEVELOPMENT INFORMATION: <br /> 02 COOLER DIMENSION PLAN SYSTEM DURING BRAZING. <br /> 3.12 PROVIDE WALT. BUMPER GUARD ARCO NTl <br /> - SCALE: 1/4"=1'-0" 6.6 LEAK TEST THE ENTIRE SYSTEM AFTER ALL REFRIGERATION <br /> 4A GLASS DISPLAY DOORS: CONNECTIONS HAVE BEEN COMPLETED. LEAK TESTING SHALL BE 2900 am/pm <br /> MANUFACTURED BY ANTHONY OR EQUAL PERFORMED WITH AN ELECTRONIC LEAK DETECTOR. <br /> 4.1 30" X 75" H. DISPLAY DOORS (SILL ATF 7-1/2" A.F.F.) 6.7 THE SYSTEM MUST BE EVACUATED WITH A VACUUM PUMP, HAVING 26'x38CAR WASH <br /> THE CAPABILITY OF PULLING A VACUUM OF 50 MICRONS OR LESS. FUEL CANOPY <br /> 4.2 ENERGY SAVER CONTROLS THE PUMP SHOULD BE CONNECTED TO BOTH THE HIGH AND LOW w/ 8 MPDS <br /> 4.3 FINISH TO BE SMOOTH BLACK. SIDES OF THE SYSTEM. <br /> 4.4 COOLER DISPLAY DOORS SHALL HAVE 2-PANE GAS FILLED NON-HEATED, 6.8 DURING CHARGING AND START-UP MAKE SURE SHIPPING RESTRAINTS SITE ADDRESS: <br /> INSULATED SAFETY GLASS ARE REMOVED AND ALL ELECTRICAL AND MECHANICAL CONNECTIONS <br /> ARE TIGHT. SET HIGH LOW PRESSURE SWITCH AS REQUIRED. 1904 DANIELS STREET <br /> 4.5 LED LIGHTING 6.9 INSTALLATION AND SERVICE OF THIS EQUIPMENT SHOULD BE <br /> 4.6 36" DEEP SHELVES, (7) PER DOOR PERFORMED BY QUALIFIED AND EXPERIENCED REFRIGERATION @FIS <br /> MECHANICS. INSTALL ALL EQUIPMENT, PIPING IN ACCORDANCE WITH MANTECA,CA <br /> CKROAD <br /> TE <br /> 4.7 KEY CYLINDER LOCK AT EACH DOOR. LOCAL AND NATIONAL CODES AND IN CONFORMANCE WITH GOOD <br /> 4.8 COOLER DISPLAY DOORS SHALL HAVE 3-PANE HEATED SAFETY GLASS PRACTICE REQUIRED FOR PROPER OPERATION. FACILITY # TBD <br /> DESIGNED BY: AWANCE Z&DM: <br /> CHECKED BY: BP REPM: <br /> DRAWN BY: ALIJANCE PM: <br /> VERSION: PROJECT NO: <br /> 16932 <br /> DRAWING TITLE: <br /> COOLER <br /> PACKAGE <br /> SHEET NO: <br /> Ql <br /> (♦ <br />