My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NORTHGATE
>
156
>
1600 - Food Program
>
PR0543736
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2020 8:59:59 AM
Creation date
4/10/2020 1:43:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0543736
PE
1624
FACILITY_ID
FA0024853
FACILITY_NAME
ROYAL T CAFE
STREET_NUMBER
156
STREET_NAME
NORTHGATE
STREET_TYPE
DR
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
156 NORTHGATE DR
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G RA <br /> Architects <br /> TRAP PRIMER V ACCESS WALL MAY EXTEND ASA <br /> PANEL INSTALLED AT 12"X12" FLOOR <br /> NEAREST HAND SINK. 0WASTE OR VENT Associates, inc. <br /> SINK .................. ............... <br /> ............................................................................................... <br /> REFER TO FLOOR PLAN FLOOR FINISH, ...................... <br /> SQUARE SCORIATED FOR LOCATION, VERIFY FINISH Af <br /> TOP WITH VANDAL CHROME WALLCOVER P.O. Box 9082 <br /> PROOF SCREW 2'-0" SQUARE (E) CONC. FLOOR SLAB, 1" MIN. AIR GAP FOR & SCREW Stockton, CA 95208-1082 <br /> PLAN FINISHED FLOOR HARD—DRAWN COPPER SAW CUT. PLUGGED TEE <br /> ADJUSTABLE LEVEL LINE W/ CONT. SLOPE CONDENSATES, PIPE SINK OR EQUIPMENT <br /> < CONTROL SLOPE 2% _#4 x 12" L KEBABS @ OTHERWISE 4" wl CLEANOUT FLOOR LINE Phone, 12091609-6801 <br /> o 70 0 or-- <br /> 12" O.C. MAX., DRILLED FIN. FLOOR Email, GRA228750gmall.com <br /> MEMBRANE <br /> TO (E) CONC. SLAB. <br /> SEE SPECIFICATIONS <br /> FOR ADDITIONAL <br /> INFORMATION (N) FLOOR DRAIN Architecture Consulting <br /> FOR <br /> CAST IRON SYSTEM <br /> TO WASTE & VENT <br /> RISER <br /> TO WASTE AND VENT 1/8" C.I. BEND BALANCE OF PIPING 5ED AR <br /> 0 <br /> SECTION SYSTEM SAME AS CLEANOUT TO GRADE <br /> G.C. TO TAMP BACK— <br /> FILL, 90% COMPACTION. GEORGE A. <br /> RODRIGUEZ <br /> No. C22875 <br /> WALL CLEANOUT REN.: MAY 31, 2019 <br /> FLOOR CLEANOUT FLOOR DRAIN FLOOR SINK 3 4 <br /> NOT TO SCALE �1 .0 NOT TO SCALE NOT TO SCALE �1.0 NOT TO SCALE �1.0 Of <br /> SEMCO" #110DIR FLASHING These drawings are property of ORA Architects & Associates, Inc., and <br /> TURNED IN ON CAST IRON are not to be reproduced, changed, copied, or reused without the <br /> VENTS 3" & LARGER ONLY, expressed written consent of GRA Architects & Associates, Inc, <br /> THREADED ROD Consultant <br /> THREADED ROD <br /> y" THREADED <br /> TO PIPE SUPPORT <br /> ATTACHMENT DETAIL <br /> REFER TO PIPE SUPPORT THIS SHEET. 24 GA. S/M 24 GA. S/M <br /> ATTACHMENT DETAIL FLASHING WITH COUNTER FLASHING <br /> STEEL ANGLE THIS SHEET. q_ <br /> --------EXTEND WHERE READ DRAW BAND TOP <br /> L'A'TF'R'AWLBRACE, PER CBC PIPE HANGER SCHEDULE TO CLEAR FRESH AIR <br /> SEE PLUMBING INTAKES, ETC. <br /> NOTES BELOW. PIPE SIZE HANGED ROD BOLT PFRMASFAL <br /> SHEETS FOR J." WATER PROOFING <br /> PIPE SIZES i"A THRU 3"n 1 i"Xl i"XW" COMPOUND ___--"SFMCO" CAULK TYPE FINISHED ROOF <br /> I THRU 1i STEEL ANGLE LATERAL COUNTER FLASHING ------- <br /> -SUPERSTRUT 1 2" THRU 2i" BRACING PER CBC SLEEVE FOR CAST IRON <br /> VENTS AND THREADED <br /> PIPE CLAMP 3" F CH. 16 REQUIREMENTS "SEMCO" SEAMLESS LEAD OR CAULK TYPE FOR 6 <br /> 10 AND SMACNA STANDARDS FLASHING #1100-8 OR ALL STEEL VENTS <br /> OLT <br /> #1100-4 W/ 8" SKIRTI <br /> AND STEEL <br /> HANGER ROD— SEE INSULATION PITCH BOOTVARIABLL <br /> SCHED. FOR SIZE <br /> HANGER RODHREADED ROD WROUGHT STEEL HOT WATER PIPE OR <br /> CLIP, TYP, 0 SET SKIRT OVER ROOF FELT FLUE <br /> '—TProject For <br /> SUPERSTRUT A-1200—HS CLEVIS HANGER��sss_ ADJUSTABLE NOTE: <br /> SEE SPECS. FOR vrNT PIPE <br /> CHANNEL, LENGTH AS AND HANGER— <br /> REQUIRED TYPE SEE SPECS. FOR GAS PIPING SHALL BE Ms. Claudia Onofre <br /> NOTE: NOTE: TYPE INSTALLED, SIZED AND NOTE: onofrecl 102@gmail.com <br /> GAS & CONDENSATE ALVANIZIED SHIELD SUPPORTED IN <br /> SUSPENDED PIPING SHALL BE SECURED, AT INTERVALS PIPING SIMILAR AT INSULATION ACCORDANCE WITH CPC "EACH VENT PIPE SHALL EXTEND THROUGH ITS FLASHING AND TERMINATE VERTICALLY <br /> NOT OT EXCEED THOSE SHOWN CPC TABLE 3-2. CHAPTER 12 AND TABLE NOT LESS THAN SIX INCHES ABOVE ROOF NOR LESS THAN ONE FOOT FROM ANY Phone: (510)309-7069 <br /> 12-8 VERTICAL SURFACE (CPC 708.0) <br /> PIPE HANGER DETAILS 5 VENT PIPE FLASING 6 ROOF PENETRATION 7 <br /> NOT TO SCALE NOT TO SCALE �1 .0 NOT TO SCALE �1 .0 <br /> Project <br /> MIN. 18" LONG #4 DOWELS @ _\ <br /> 48 O.C. ALONG THE LENGTH Royal T Cafe <br /> OF THE REPAIR W/ 6" MIN, HOT WATER DEMANDS <br /> EPDXY EMBEDMENT INTO NEW 5" THICK CONC. W1 FIXTURE CONNECTION SIZE Tenant Improvements <br /> EXIST. SLAB; STAGGER DOWEL (2)#3 CONTBARSWASTE COLD WATER HOT WATER <br /> ONEA. SIDE OF THE REPAIR FIXTURE SYM BRANCHI OUTLET TRAP VENT BRANCH OUftET BRANCH OUTLET 156 Northgate Drive <br /> — <br /> 24„ FIXTURES NO. OF UNITS X GPH = TOTAL GPH LAVATORY HAND SINK LAV. 2” 111/2" 11/2" 11/2" 1 L2:] 2 1 2'I L2' <br /> L�]L <br /> PREP. SINK PS 2" 11/2" 11/2" 11/2" L/2 1/2 L/2 L/2 Manteca, CA 95336 <br /> 6" MI EXIST. 5 _ __ <br /> CONC. SLAB LAVATORY I X 5 5 3 COMP. SINK 3—C 2" 11/2" 11/2" 11/2" 1/2' LL2� LL2': 1/2' <br /> _ <br /> JANITOR'S SINK I X 20 20 JAN. SERVICE SINK SS 3" 3" 3" 1 2" 11/2 fl� 11 <br /> 11/2" 1/21/2" <br /> FLOOR DRAIN FD 2" 11/2" 1 1/2"ll 1/2"1 -- I -- I <br /> HAND SINK I X 10 10 FLOOR SINK FS 2" 111/2" 1 1/2"11 1/2"1 <br /> -'� - - -��oa- - - - 3—COMP. SINK I X 90 90 Sheet Contents <br /> I/ /\x/ <br /> TOTAL 125 <br /> DOMESTIC COLD WATER SIZING CHART Mechanical/Plumbing <br /> Details & Schedules <br /> BACKFILL <br /> 11 / \. / F.U. <br /> y <br /> M11111 FOR GAS WATER HEATER: PIPE SIZE <br /> 125 GNP x 80 DEGREE RISE x 11 = 110,000 BTU F.T. F.V. <br /> ***PROVIDE GAS WATER HEATER W1 AT LEAST A RATING OF 110,000 BTU 1/2" 3 <br /> 3/4" 10 <br /> 19 <br /> 1 1/4" 54 13 <br /> 1 1/2" 90 30 <br /> DRAWING STATUS DATE <br /> PIPE MATERIAL SCHEDULE 2" 236 116 <br /> k& ABOVE GRADE 2 1/2" 431 295 ISSUED 05-23-18 <br /> NOT USED SLAB REPAIR B.G. BELOW GRADE THE SIZING CHART IS BASED ON <br /> SCALE: 1 112" 1'-0" CP THE 2016 CPC APPENDIX 'A' <br /> C, WITH A p OF 10.0 PSI PER 100 FT <br /> 1\1 �p <� w/ MAXIMUM VELOCITY OF 8ft/SEC, <br /> SERVICES REMARKS <br /> WATER A.G. • <br /> DOMESTIC HOT WATER SIZING CHART <br /> B.G. • F.U. <br /> PIPE SIZE <br /> WASTE A.G. • F.T. F.v. BUILDING PERMIT NO.: TBD <br /> B.G. • 1/201 3 DRAWN BY: <br /> 3/4" 8 NEO KLAYBO <br /> VENT A.G, 0 SEE WASTE PIPE 1 18 CHECKED BY: GRA <br /> B.G. • 1 1/4" 28 <br /> INDIRECT1 1/2" 45 10 SCALE: AS NOTED <br /> WASTE A.G. CONDENSATE DRAIN 210 ill 39 <br /> PROJECT NO.: ONO-21804070 <br /> 2 1/2" 236 116 <br /> B.G. • CONDENSATE DRAIN iI I <br /> THE SIZING CHART IS BASED ON SHEET: <br /> GAS A.G. THE 2016 CPC APPENDIX 'A' <br /> WITH A A P OF 10,0 PSI PER 140 FT <br /> B,G. • w/ MAXIMUM VELOCITY OF 5ft/SEC. M P 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.