Laserfiche WebLink
tl <br /> ? Z Y Z <br /> U O S <br /> 1 a N SERVICES, INCORPORATED <br /> L MPDS-UN5098-12 <br /> L F i Com' ._. <br /> October 16, 1996 <br /> Unocal Corporation <br /> 2000 Crow Canyon Place, Suite 400 A91IR <br /> P O Box 5155 <br /> San Ramon, California 94583 <br /> Attention Ms Tina R Berry <br /> NOV 13 1996 <br /> RE Quarterly Data Report ENVIRONMENTAL <br /> PERMIT/SERVICES <br /> Former Unocal Service Station #5098 <br /> 5606 Pacific Avenue <br /> Stockton, California <br /> Dear Ms Berry <br /> This data report presents the results of the most recent quarter of monitoring and sampling of the <br /> monitoring wells at the referenced site by MPDS Services, Inc <br /> RECENT FIELD ACTIVITIES <br /> The Unocal monitoring wells that were monitored and sampled during this quarter are indicated in Table <br /> 1 Prior to sampling, the Unocal wells were checked for depth to water and the presence of free <br /> product or sheen The monitoring data and the ground water elevations for the Unocal wells are <br /> summarized in Table 1 <br /> A point monitoring event was conducted with the consultant for the nearby Montgomery Ward site on <br /> September 17, 1996 The monitoring data collected for Montgomery Ward's monitoring wells (provided <br /> by Environmental Audit, Inc ) are summarized in Table 3 The ground water flow direction in the <br /> vicinity of the Unocal and Montgomery Ward sites during the most recent quarter is shown on the <br /> attached Figure 1 <br /> Ground water samples were collected from the Unocal wells on September 17, 1996 Prior to sampling, <br /> the Unocal wells were each purged of between 8 and 13 5 gallons of water During purging operations, <br /> the field parameters pH, temperature, and electrical conductivity were recorded on the purging/sampling <br /> data sheets which are attached to this report Once the field parameters were observed to stabilize, and <br /> where possible, a minimum of approximately four casing volumes had been removed from each well, <br /> samples were then collected using a clean Teflon bailer The samples were decanted into clean VOA <br /> vials and/or one-liter amber bottles, as appropriate, which were then sealed with Teflon-lined screw <br /> caps, labeled, and stored in a cooler, on ice, until delivery to a state-certified laboratory Field blank, <br /> Equipment blank and Trip blank samples (denoted as ESI, ES2 and ES3 respectively) were also <br /> collected for quality assurance and control. MPDS Services, Inc transported the purged ground water <br /> to the Unocal Refinery located in Rodeo, California, for treatment and discharge to San Pablo Bay under <br /> NPDES permit <br /> ANALYTICAL RESULTS <br /> The ground water samples collected from the Unocal wells were analyzed at Sequoia Analytical <br /> boratory and were accompanied by properly executed Chain of Custody documentation The <br /> tical results of the ground water samples collected from the Unocal wells to date are summarized <br /> 2401 Stanwell Drive Suite 400 Concord CA 94520 <br /> TEL (510) 602-5120 FAX (510) 689-1918 <br />