Laserfiche WebLink
' LABORATORY NARRATIVE <br /> Modified TO-3 (Gas range) <br />' ENSR <br /> Workorder#0408614 <br />' Fourteen 1 Liter Summa Canister samples were received on August 31, 2004 The laboratory performed <br /> analysis for volatile organic compounds in air via. modified EPA Method TO-3 using gas chromatography <br /> with photo ionization and flame ionization detection The method involves concentrating up to 200 mL of <br /> sample The concentrated aliquot is then dry purged to remove water vapor prior to entenng the <br /> chromatographic system The TPH (Gasoline Range) results are calculated using the response factor of <br /> Gasoline and correspond to the range of hydrocarbons from C5 to C 10 A molecular weight of 100 is used <br />' to convert the TPH (Gasoline Range) ppmv result to ug/L See the data sheets for the reporting limits for <br /> each compound <br />' Method modifications taken to run these samples include <br /> Requirement TO-3 ATL Modifications <br />' Daily Calibration Standard Prior to sample analysis Prior to sample analysts and after the analytical batch</= <br /> Frequency and every 4-6 hrs 20 samples <br /> Initial Calibration Calculation 4-point calibration 5-point calibration using average Response Factor <br /> using a linear <br /> regression model <br /> Initial Calibration Frequency Weekly When daily calibration standard recovery is outside 75 - <br />' 125% or upon significant changes to procedure or <br /> instrumentation <br /> Moisture Control Nafion system Sorbent system <br /> Minimum Detection Limit(MDL) Calculated using the 40 CFR Pt 136 App B <br /> equation DL=A}3 3S, <br />' where A is intercept of <br /> calibration line and S is <br /> the standard deviation <br /> of at least 3 reps of <br />' low level standard <br /> Preparation of Standards Levels achieved Levels achieved through loading various volumes of the <br /> through dilution of gas gas mixture <br />' mixture <br /> Receiving Notes <br /> The Chain of Custody (COC) information for samples VEW-2,VEW-6,VEW-7, VEW-8, VEW-9, <br /> VEW-10, VEW-11 and VEW-12 did not match the entries on the sample tags with regard to sample <br /> identification The discrepancy was noted in the Sample Receipt Confiri-nation email/fax and the information <br /> on the COC was used to process and report the samples <br /> The Chain of Custody (COC:) information for samples VEW-8 and VEW-12 did not match the entries on <br /> the sample canisters in regard to the can numbers The discrepancy was noted in the Sample Receipt <br />' Confirmation email/fax and the information on the cans were used to process and report the samples <br />' Page 3 of 25 <br />