REMOVAL_2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
1825
>
2300 - Underground Storage Tank Program
>
PR0540852
>
REMOVAL_2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 1:19:46 PM
Creation date
4/14/2020 8:39:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2016
RECORD_ID
PR0540852
PE
2361 - UST FACILITY
FACILITY_ID
FA0023354
FACILITY_NAME
CCJ & S LLC (VACANT PROPERTY)
STREET_NUMBER
1825
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95205
APN
15514015
CURRENT_STATUS
Inactive, non-billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1825 E DR MARTIN LUTHER KING JR BLVD STOCKTON 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAID JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> UST WORKSHEET FOR SITE CLOSURE EVALUATION <br /> I. FACILITY/TANK INFORMATION DATE: 1 5/5/16 <br /> SITE/FACILITY NAME: CCJ&S LLC vacantproperty) STATUS CODE: <br /> ADDRESS: 1825 E. Dr. Martin Luther King,Jr. Blvd. CITY: I Stockton <br /> FA#: 0023354 PR# :0540852 TANK# 0520797 <br /> TANK SIZE: 550 gallons FUEL TYPE: unknown <br /> Il. GENERAL SITE HISTORY <br /> Is Permit Current? 0 Yes ❑ No ❑n/a Documented Soil/GW Contamination?*** ❑ Yes d No <br /> Number of Tanks at Facility 1 Age of Tanks(if available) unknown Type of Tank OSteel ❑Fiberglass ❑Single <br /> ❑Dual <br /> III. TANK HISTORY <br /> Was Tank Tested? ❑ Yes 0 No Failed Testing? ❑ Yes ❑ No 0 n/a If Yes, Provide Dates: n/a <br /> Was Tank System Repaired? ❑Yes❑No 0 n/a If Yes, Describe Repair: 0 n/a <br /> ❑ BTEX 0 TPH-G 0 TPH-D ❑ LEAD <br /> Was Repair Done Under Permit? ❑Yes❑No On/a Were Soil Samples Analyzed? 0 Yes ❑ No ❑ EDB 0 OTHER VOCs, Semi-VOCs, <br /> T22 Metals, PCB,Oil&Grease <br /> Type of Failure/Discharge: ❑ Catastrophic ❑ Long-term Leak ❑ Overfill 0 Unknown ❑ Other <br /> IV. REMOVAL HISTORY(Attach File) <br /> Soil Samples Received? 0 Yes ❑ No Seasonal High Depth to GW 50 ft bgs Year/Reference Spring 1997 <br /> Onsite and/or Nearby Well(s)? ❑Yes 0 No <br /> LJ Irrigation: # Distance to Tank ft � Score 10 C Score 9 C <br /> ❑ Domestic:# Distance to Tank ftO points if 0 points if 0 Score 5 points if <br /> L3Public: # Distance to Tank ft R condition is R condition is R condition is met <br /> V. SITE FEATURE—LEACHING POTENTIAL ANALYSIS E met E met E <br /> Minimum Depth to Groundwater from Soil Sample(feet) >100 51 —100 5 25-501 <br /> Fractures in Subsurface(applies to foothill or mountain areas) 10 None Unknown Present <br /> Average Annual Precipitation(14 inches for SJC area) -------- <10 9 10-25 -------- 26-402 <br /> Man-Made Conduits which Increase Vertical Migration None 9 Unknown Present <br /> i.e.septic sstems,water wells, ponds) <br /> Unique Site Features: Recharge Area, Coarse Soil(coarse sands, 10 None At Least One More Than One <br /> gravels),nearby wells <br /> Column Totals Total Points 20 + 18 + 5 = 43 <br /> Sample Results for BTEX: Range of Total Points 49 Points or More 41 —48 Points 40 Points or Less <br /> Maximum Allowable BTEX B T E X B T E X N/A3 <br /> Levels ppm 1.0 50 50 1 50 0.3 0.3 1.0 1.0 <br /> Sample Results for TPH: Maximum Gasoline 1,000 100 10 <br /> Allowable TPH <br /> Levels ppm Diesel 10,000 1,000 100 <br /> Footnotes: ***If documented soil and/or groundwater contamination is present,do not complete leaching potential analysis(i.e.site is already on the contamination list). <br /> 1 If depth is>5 feet and<25 feet,score 0 points. If depth is-5 feet,do not use table. 2 If precipitation is>40 inches,score 0 points. <br /> 3 Levels for BTEX are not applicable at a concentration of 10 ppm for TPH—Gasoline or 100 ppm for TPH-Diesel. <br /> VI. STAFF RECOMMENDATION/REFERRAL/REVIEW <br /> 1. Are BTEX or TPH Concentrations>Allowable Levels? ❑Yes 0 No 2. If No, Is Site Closure Recommended? 0 Yes ❑ No <br /> Completed By: Stacy River Date Referred to Site Mitigation Unit for Final Actiont 5/5/16 <br /> Reviewed By: �� Concur with Staff Recommendation es ❑ No <br /> Date Closure Letter Mailed tAll Cases are Referred to Site Mitigation for Final Action <br /> EH 23-0080(Rev 11/14/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.