Laserfiche WebLink
Sa Joa i County Environmental Health . 'partment <br /> Unitied Hazardous Waste Generator Pr.,gram <br /> Site Name Address <br /> VIOLATIONS <br /> TANKS <br /> (Refer to TIP-5 Tank A sessment Worksheet and Appendices) <br /> 61 (CCR) Chapter 15- Fai ed to determine if tank is leaking or unfit . <br /> 62 (CCR) Chapter 15-Ass ssment not sufficient. <br /> 63 (CCR) Chapter 15-If fo nd leaking or unfit, failed to comply. <br /> 64 (CCR)Chapter 15- Fai ed to retain on-site required certification. <br /> 65 (CCR) Chapter 15-Fail d to provide secondary containment. <br /> 66 (CCR) Chapter 15-Pla ed hazardous waste or reagents in tank system which caused the tank, containment <br /> system or ancillary equ pment to leak, corrode, rupture, or fail. <br /> 67 (CCR) Chapter 15-Fail d to use controls and practices to prevent spillage and overflows from tank system. <br /> 68 (CCR) Chapter 15-Fail d to prevent overtopping. <br /> 69 (CCR) Chapter 15-Fail d to conduct daily inspections. <br /> 70 (CCR)Chapter 15-Fail d to inspect cathodic protection system. <br /> 71 (CCR) Chapter 15-Fail d to immediately remove tank system or secondary containment system that had leaked or <br /> spilled. <br /> 72 (CCR)Chapter 15-Duri g tank closure, failed to remove or decontaminated all waste residues, contaminated tank <br /> system, soils, and man ge them as hazardous waste. <br /> 73 (CCR) Chapter 15-Fail d to manage ignitable or reactive waste properly. <br /> 74 (CCR)Chapter 15-Fail d to manage incompatible wastes properly. <br /> UNIVERSAL WASTE <br /> 75. 66273.14 (CCR) Small uantity Handler did not mark or label the universal waste as specified in this section. <br /> 76. 66273.15(a) (CCR)SmII Quantity Handler had universal waste onsite for more than one year. <br /> 77. 66273.15(c) (CCR)Sm II Quantity Handler was unable to demonstrate the length of time the universal waste has <br /> been accumulated from the date it became a waste or was received. <br /> 78. 66273.1 (CCR) Small Q antity Handler did not inform employees who handle universal waste proper handling and <br /> emergency procedures. <br /> 79. 66273.32 (CCR) Large uantity Handler did not notify the EPA Regional Administrator to obtain an EPA ID <br /> number. <br /> 80. 66273.33 (CCR) Large uantity Handler did not manage universal waste according to this section. <br /> 81. 66273.34 (CCR) Large uantity Handler did not label universal waste according to this section. <br /> 82. 66273.35(a) (CCR) Lar e Quantity Handler had universal waste onsite for more than one year. <br /> 83. 66273.35(b) (CCR) Lar e Quantity Handler was unable to demonstrate the length of time the universal waste has <br /> been accumulated from the date it became a waste or was received. <br /> 84. 66273.36 (CCR) Large uantity Handler did not inform employees who handle universal waste proper handling <br /> and emergency procedures <br /> 85. 66273.39 (CCR) Large uantity Handler did not keep records of each shipment of universal waste according to <br /> this section. <br /> 86. 66273.82(b) (CCR) Cat ode Ray Tube (CRT) handler that accepts more than 5 CRT devices per calendar year <br /> from any offsite source f iled to notify DTSC and the CUPA according to section. <br /> 87. 66273.82(c) (CCR)CRT handler that generates 5,000 kilograms or more of CRT material per calendar year failed <br /> to notify DTSC and the UPA according to this section. <br /> OTHER <br /> 88 See attached "Continuat on-Official Inspection Report'for violation(s) not listed above. <br /> SPCC <br /> 89 25270-25270.13 (HSC) pill Prevention Control and Countermeasure Plan on site for aboveground <br /> petroleum storage tank( ). <br /> v Y Page of <br /> E nitialed by Date <br /> 9/3 /02 <br />