<br /> GENERAL NOTES
<br /> WASTE/VENT SYSTEM BRIEDERT TYPE 0°
<br /> "B" FLUE CAP Q N U
<br /> SIZE: FIXTURE UNITS:
<br /> W 'I:d CL
<br /> W CL W .a C)
<br /> (Inches) WASTE ' VENT (Z > z
<br /> 1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, SPECIFICATIONS, LOCAL © 0 -0
<br /> ORDINANCES AND INDUSTRY STANDARDS. 1 114" 1 1 Z (e LL
<br /> co
<br /> 2. SEISMIC RESTRAINT: PIPING SHALL BE SUPPORTED AND BRACED IN ACCORDANCE2 W LO W
<br /> Co
<br /> WITH THE CBC AND THE LATEST EDITION OF SMACNA "GUIDELINES" FOR SEISMIC 1 112 1 $ "SEMCO" CAULK TYPE CONTER Q
<br /> Lu 00
<br /> RESTRAINTS OF PLUMBING SYSTEMS AND MECHANICAL SYSTEMS. 2 STORM COLLAR WITH FLASHING SLEEVE FOR CAST IRON ALO
<br /> 2" 8 24 DRAW BAND AT TOP VENTS AND THREADED OR CAULK [C)
<br /> 3. ALL INSULATION AND SEALfNG PRODUCTS USED IN THE BUILDING SHALL HAVE A SURFACE 2. TYPE FOR ALL STEEL VENTS
<br /> 2 112" 14 48 r
<br /> BURNING CHARACTERISTIC WITH FLAME SPREAD/SMOKE DEVELOPED INDEX OF 25/50 �p
<br /> MAXIMUM, WHEN TESTED AS COMPOSITE INSTALLATION INCLUDING INSULATION, TAPES3.
<br /> FACING MATERIALS, JACKETS AND ADHESIVES. 3 35 84 ROOFING cfl
<br /> 4" 216 4 256 JJJJJJJ J JJJ
<br /> THE ANNULAR SPACE BETWEEN PIPE SLEEVES AND THE PIPE THROUGH ALL RATED WALLS
<br /> ANDFLOORS SHALL BE FIRESTOPPED. FIRESTOPPING OF ALL PIPE PENETRATIONS SHALLjJjJ
<br /> COMPLY WITH U.L. REQUIREMENTS. MANUFACTURER PREAPPROVED UL PENETRATION FOR 5 428 600 J JJJ (-
<br /> PIPE MATERIAL AND SURFACE PENETRATED SHALL BE USED. PENETRATIONS SHALL BE 61 720 1380
<br /> 3M, PROSET, OR APPROVED EQUAL, SUBMIT SHOP DRAWINGS.
<br /> WASTE/VENT NOTES: �, ° :3 _ a)
<br /> COORDINATE THE FOLLOWING WITH ARCHITECTURAL, STRUCTURAL, PLUMBING AND ELECTRICAL 0 o c
<br /> DRAWINGS AND ELEMENTS AS INSTALLED, INCLUDING EXISTING BUILDING SYSTEMS: 1 BASED ON HORIZONTAL FLOW 1" AIR SPAC o VN o
<br /> EXISTING ROOF p o c = 'o
<br /> EXACT LOCATION OF ALL EQUIPMENT. v ° ° E o
<br /> ALL PENETRATIONS THRU ROOF, WALLS AND FLOORS. 2 EXCEPT SIX-U NIT TRAPS OR WATER CLOSETS ° ° STRUCTURE �, �, (D C:
<br /> EXACT SIZE AND ROUTING OF DUCTWORK AND PIPING. 3 NOT TO EXCEEDTHREE(3)WATER CLOSETS CLN '
<br /> OR SIX-UNIT TRAPS ON ANY HORIZONTAL 1" x 1/8" RING CLAMP o
<br /> BRANCH OR DRAIN. :'- a a o N
<br /> ALL PIPING LOCATED IN WALLS OR ABOVE CEILING HAVING SHUTOFF VALVES OR OTHER AND SUPPORT BRACKETS. °
<br /> DEVICES REQUIRING ACCESS FOR OPERATION OR MAINTENANCE SHALL BE PROVIDED 4 BASED ON ONE-FOURTH(1/4)INCH PERDOUBLE WALL FLUE SECURE WITH 1/4" DIA. x 2" 5 a� E-E n c: °u
<br /> WITH ACCESS DOORS OF ADEQUATE SIZE FOR SERVICE. FOOT SLOPE. FOR ONE-EIGHTH INCH PER LAG SCREWS,
<br /> FOOT SLOPE,MULTIPLY HORIZONTAL FIXTURES
<br /> rnmo� oc �'>
<br /> UNITS BY A FACTOR OF 0 a.
<br /> ANY DAMAGE TO EXISTING BUILDING ARCHITECTURAL, STRUCTURAL, MECHANICAL AND VENT PIPE - 5EE PLAN FOR SIZE, ATTACH ° a a
<br /> ELECTRICAL SYSTEMS THAT OCCURS DURING THE WORK SHALL BE RESTORED TO THE IL
<br /> s. TAKEN FROM CPCrABLE7as.2. x o a �o ° _j
<br /> ELECTRICAL
<br /> TO STRUCTURE PER SMACNA GUIDELINES a a X T ° ... o
<br /> ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. .> °
<br /> LOCATIONS, SIZES AND DEPTHS SHOWN FOR ALL EXISTING UTILITIES AND EQUIPMENT SHOWN = a a7 Q N °
<br /> ARE APPROXIMATE ONLY, CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE LOCATION -Cc 1 C E' .� o
<br /> AND ADEQUACY OF DEPTH OF ALL EXISTING UTILITIES AND/OR EQUIPMENT SHOWN TO BE Q E I �l ! DETAIL - 6-o 0-0.2 w
<br /> CONNECTED TO PRIOR TO BEGINNING WORK. CLEANOUTS -r-Q
<br /> ALL CONTRACTORS SHALL VISIT THE SITE PRIOR TO BIDDING TO SURVEY EXISTING PIPE SIZE: CLEANOUT SIZE: THREADS SCALE : NONE ln,� E �°0 o
<br /> FIELD CONDITIONS. AFTER THE CONTRACTOR IS AWARDED THE CONTRACT, THE (Inches) (Inches) (Per Inch)
<br /> CONTRACTOR SHALL SURVEY EXISTING FIELD CONDITIONS IN DETAIL, REVISIONS/DATE
<br /> 1 112" 1 1/2" 11 112 zL
<br /> 2" 1 112" 11 112"
<br /> 2 112" 2 112" 8 SEE FLUE VENT THROUGH ROOF DETAIL
<br /> 1 2
<br /> HOT WATER TO SYSTEM CW, MAKE-UP D
<br /> 3" 2 1/2" 8
<br /> 1" GAS LINE UNION
<br /> 4" &Larger 3 1/2" 8
<br /> BRANCH S0 i V G SCHEDULE CLEANOUT NOTES: -
<br /> WASTE COLD WATER HOT WATER 1. TAKEN FROM CPC TABLE 707 1. BLOCK SADDLE BETWEEN
<br /> FIXTURE SYMBOL VENT
<br /> BRANCH OUTLET BRANCH OUTLET BRANCH OUTLET HEATER AND WALL 2" WIDE 24 GA STEEL STRAP Seal;
<br /> / / „ / AROUND ET, SECURE TOE1C��
<br /> PEDICURE SINK PS 2" 2" 1-12" 3 4" 1/2 3 4' 1/2 PLUMBING NOTES: WOOD FRAME WITH 1/4"0 LAG o� WAN
<br /> HAND WASH SINK HWS 2" 2" 1-1/2" 3/4" 1/2" 3/4" 1/2" 1, ALL COLD WATER, HOT WATER,AND CONDENSATE o SCREWS, 2" MIN. EMBEDMENT
<br /> DRAIN LINES SHALL BE TYPE"L"COPPER UNLESS N0, 63640
<br /> CLOTH WASHER CW 2" 2" 1-1 2" 3 4" 1 2" 3 4" 1 2" NOTED OTHERWISE(CPC Section 604.2). 1/4" DIA. x 3" LONG LAG SCREW
<br /> / / / / / Exp. 09/1 2a20 y�
<br /> 2. ALL GAS PIPING SHALL BE STANDARD WEIGHT POSITIVELY ATTACHED TO BUILDING ET
<br /> FLOOR SINK FS 2" 2" 2" - - - T WROUGHT IRON OR STEEL(GALVANIZED OR BLACK) FRAME MEMBERS, LAG SCREW TO �S'] C ! V �P
<br /> OR YELLOW BRASS(CONTAINING<75%COPPER) PENETRATE WOOD MEMBERS AT 1 9
<br /> TRAP PRIMER TP - - -- 1/2" 1/2" - - PER CPC Section 1210 1 LEAST ONE INCH„ TYP. AT 1/3 AND C
<br /> 3. SANITARY SEWER LINES IN AND/OR UNDER THE 2/3 HEIGHT OF HEATER.
<br /> FLOOR DRAIN FD 2" 2' 2" - - - - BUILDING STRUCTURE SHALL BE CAST IRON,ABS OR PVC.
<br /> ABS AND PVC WASTE&VENT LINES 8HAL L 3/4" PRESSURE AND
<br /> WATER CLOSET WC 2" 3" 3" 3/4" 1/2" - - BE LIMITED TO BUILDINGS NOT EXCEEDING GWH ,
<br /> THREE FLOORS ABOVE GRADE,OR PER LOCAL NOTES: 1 RUN DISCHARGE TO MOTEMPERATURE RELIEF VALVEALVE
<br /> LAVATORY LV 2" 2" 1-1/2" 3/4" 1/2" 3/4' 1/2" ORDINANCES RFFER TO CPC Section 701
<br /> FOR ADDITIONAL REQUIREMENTS. 1. PROVIDE DIELECTRIC UNIONS AT
<br /> ALL CONNECTIONS TO WATER HEATER.
<br /> 4. WASTE VENT PIPING SHALL BE CAST IRON,ABS OR
<br /> PVC IN AND/OR UNDER THE BUILDING STRUCTURE.
<br /> ABS AND PVC WASTE&VENT LINES SHALL 2. INSTALL STRAPS AT TOP 113 AND
<br /> BE LIMITED TO BUILDINGS NOT EXCEEDING BOTTOM 1/3 OF WATER HEATER.
<br /> THREE FLOORS ABOVE GRADE,OR PER LOCAL
<br /> ORDINANCES. REFER TO CPC Section 903
<br /> FOR ADDITIONAL REQUIREMENTS-
<br /> 5. HORIZONTAL DRAINAGE PIPING SHALL HAVE A C A S WATER H E A T E R
<br /> MINIMUM SLOPE OF 2%A5 PER CPC 708A.
<br /> NOTE: PROVIDE BRANCH LINES TO FIXTURES AS SHOWN IN SCHEDULE, UON ON PLANS,
<br /> SCALE NONE 42D
<br /> EQUIPMENT SCHEDULE
<br /> UNIT DESCRIPTIONILU
<br /> Q
<br /> Q�
<br /> WH GAS WATER HEATER
<br /> 1 "RHEEM" MODEL 75-70 GAS WATER HEATER. 75 GAL CAPACITY, WATER AND WASTE SERVICE CALCULATIONS C
<br /> 70,000 BTU WITH 202 GPH RECOVERY AT 60°F TEMPERATURE RISE.
<br /> FT EXPANSION TANK JOB NAME:
<br /> 1 "AMTROL" MODEL ST-5-C . 2.1 GALLON TANK VOLUME, 0.43 ACCEPTANCE FIXTURE TYPE NO. WASTE COLD WATER HOT WATER TOTAL O
<br /> FACTOR, ASME RATING. FOR MOUNTING SEE 1/P0.1. WATER
<br /> 3S 3-COMPARTMENT SINKC
<br /> SINK, VALUE SERIESC96 BOWL18"X24"X14" FU TOTAL FU TOTAL FU TOTAL FU a
<br /> 1 WATER CLOSET 1 4 4 2.5 2.5 0 0 2.5 [�
<br /> HS HANDSINK LAVATORY 1 1 1 0.75 0.75 0.75 0.75 1
<br /> 1 ADVANCE TABCO, BOWL 10"X15"X5"
<br /> HAND SINK 2 1 2 0.75 1.5 0.75 1.5 2
<br /> FS FLOOR SINK MOP SINK 1 3 3 2.25 2.25 2.25 2.25 3
<br /> 1 FD-2375-K-NH2, W/ SEEPAGE FLANGE, 2" PIPE CONNECTION WATER PIPE SIZING CHART
<br /> FLOOR SINK RECEPTOR 3 3 9 0 0 0 0 0
<br /> TR TRAP PRIMER, PRIME-RITE PR500 PIPE SIZES CALCULATED BASED ON UPC/CPC APPENDIXA 3-COMP SINK 1 3 3 2.25 2.25 2.25 2.25 3
<br /> 1 SIZE: TYPE L COPPER CW MAX FLOW CW FIXTURE UNIT VALUES HW MAX FLOW HWFU PREP SINK 1 3 3 1.5 1.5 1.5 1.5 2
<br /> MS MOP SINK FLOOR DRAIN 1 1 1 0 0 0 0 0
<br /> EAGLE GROUP, EG20.01, FLOOR MOUNT, BOWL SIZE 24"X24"X8„ IOMETER INTERNAL GPM FPS FLUSH TANK FLUSH GPM FPS NOT WATER
<br /> 1 DIAMETER DIAMETER VALVE TOTALFU 26,0 10.$ $.3 13.5
<br /> PS PREP SINK 112" 0.545 2.0 2.7 0 0 2.0 2.7 0 EQUIVALENT COLD WATER FLOW RATE (GPM): 11 Drawn By
<br /> 1 SINK, SH24241 L314" 0.785 5.2 3.4 6 p 5.2 3.4 6 ADDITIONAL DEMAND LOAD (GPM) 0 A. RANG
<br /> FLOOR DRAIN 1" 1.025 10.4 4.1 13 0 10.4 4.1 13 PRESSURE AVAILABLE AT MAIN(PSI): 40 Checked By
<br /> FD
<br /> 1 FD-2290--NH2, 2" PIPE CONNECTION 1-114" 1.265 18.2 4.6 26 0 18.2 4.6 26 PRESSURE BOOSTER PUMP 0 Date 8-28-19
<br /> LAVATORY MINIMUM REQUIRED FIXTURE PRESSURE (PSI): 15
<br /> LAV AMERICAN STANDARD "DECLYN" WALL-HUNG, WHITE COLOR, POP UP DRAIN STAINER, P-TRAP 1 1/2" 1.505 28.7 5.2 49 11 27.7 5.0 46 scale
<br /> 1 STOP AND SUPPLIES. FAUCET: AMERICAN STAND, CERAMIX 2000.101, ELEVATION RISE (FT): 10
<br /> SINGLE LEVER OPERATED WITH MAXIMUM FLOW RATE OF 0,4 GPM, 2" 1.985 59.4 6.2 170 73 48.2 5.0 119 METER LOSS (PSI): 5 Job No. AS NOTED
<br /> 2-112" 2.465 104.9 7.1 401 265 74.4 5.0 245 WC
<br /> WATER CLOSET, AMERICAN STANDARD 1.1 GPF, MADERA ADA BACKFLOW PREVENTER LOSS(PSI): 10
<br /> 1 18" HIGH, ELONGATED, OPEN FRONT, FLUSHOMETER TOILET SYSTEM 3" 2.945 167.6 7.9 731 680 106.2 5.0 411 ADDITIONAL LOSS/=S (PSI): 0
<br /> MAXIMUM FLOW RATE OF 1.1 GALLON PER FLUSH. PLUMBING
<br /> 4" 3.905 29$.6 8.0 1738 1738 186.6 5.0 847 EQUIVALENT PIPE LENGTH FROM METER TO MOST REMOTE FIXTURE(FT): 100 DETAIL PIAN
<br /> BF BACKFLOW PREVENTION DEVICE, PRESSURE DETECT TYPE
<br /> 1 MODEL WILKINS 720A 0.500" 5" 4.875 465.4 s.0 3291 3291 290.9 5.0 1668 FRICTION LOSS PRESSURE AVAILABLE(PSI): 5.66
<br /> 6" 5.845 669.1 8.0 5101 5101 418,2 5,0 2843 MAXIMUM ALLOWABLE FRICTION LOSS (PSV100 FT): 5.66 Drawing No.
<br /> 8" 7.725 1168.7 8,0 8300 8300 730.4 5.0 5650 WATER FLOW VELOCITY(FPS): 4,28
<br /> 10" 9.625 1814.3 8.0 8300 8300 1133.9 5.0 8300 CALCULATED FRICTION HEAD LOSS(PSI/100 FT): 4.16 FM2