Laserfiche WebLink
TERMINATE 10'-0"FROM <br /> ANY OUTSIDE AIR INTAKE <br /> OR OPENABLE WINDOW, WATER PIPE E S I ZIN G <br /> 112"CW 2'-0" MIN FROM ANY WALL SPECIFICATIONS <br /> OR STRUCTURE. <br /> DESC. QTY. DFU WSFU HWSFU HW FIXTURE DEMANDINDICATE <br /> 1. PROVIDE ALL PLUMBING!TENS D ON THE DRAWINGS, DESCRIBED HEREIN OR OTHERWISE =, e;=.::"I' <br /> 112"GV SEALANT LAV-1 1 <br /> 1.0 1.6 075 5 GPH REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, INCLUDING: <br /> S--1 1 3,0 3.0 2,25 15 GPH A. PLUMBING FIXTURES, 9T � _; rt;: • <br /> TRAP PRIME - S-2 <br /> R TP 1 1 ..... <br /> STEEL <br /> FITTINGS AND EQUIPMENT, <br /> ACCESS -- �- COUNTER FLASHING 3.0 3.0 2.25 42 GPH B HOT AND COLD WATER SYSTEMS. :• F��.ere:...°.3.6,. <br /> WC 1 1 4.0 2.5 ----------- <br /> PANEL SLEEVEFS-WC 1 ____ ----_ - -- C DRAIN WASTE AND VENT PIPING SYSTEMS. <br /> 3.0 ----------- <br /> HEIGHT <br /> ----- D. INDIRECT WASTE PIPING, INCLUDING ALL VALVES,TRAPS, PIPING AND ACCESSORIES FOR ALL : •�`• •€� � �` iny s <br /> PER <br /> LOCAL CODE TOTAL 14.0 9,5 5,25 52 GPH KITCHEN EQUIPMENT. SIZE PER EQUIPMENT REQUIREMENTS. (ROOF DRAiNAGE IS SHOWN ON � ,1 <br /> OR 6"MIN -_ SEAMLESS LEAD <br /> FLASHING PRESSURE CALCULATION: ARCHITECTURAL DRAWINGS) VF� <br /> ai <br /> 1. METER LOSS 2. COMPLY WITH ALL APPLICABLE CODES, STANDARDS AND ORDINANCES,INCLUDING REQUIREMENTS a r c h i t e C t u r e <br /> UNION 10 PSI OF THE CALIFORNIA PLUMBING CODE{CPC),CURRENT EDITION. e n g i n e e r s n g <br /> z STEEL REINFORCED 2. BACKFLOW DEVICE LOSS: 10,0 PSI <br /> STUD WALL - /2"CW TUBING / ` 3, ELEVATION PRESSURE LOSS(FT x 0.5): 1.0 PSI 3. THESE DRAWINGS AND SPECIFICATIONS REFLECT A STANDARD DE <br /> CoSIGN WHICH MUST 13E OOT 5.0 PSI <br /> OR MODIFIED FOR EACH APPLICATION AS A MINIMUM,VERIFY ALLEQUIPMENT LOADS AND <br /> WATERTIGHT Sc �ssocla�es� <br /> r FLOOR DRAIN SEAL 4, FILTERIDEVICES: REQUIREMENTS, PIPE AND SERVICE SIZES <br /> WATERTIGHT / TOTAL PRESSURE LOSS: SITE CONDITIONS, LOCAL ORDINANCES AND CODES, ETC. 867 Pacific Street, Suite 120 <br /> EOOF SEALANT <br /> 20.0 PSI San Luis Obispo,CA 93401 <br /> FINISHED FLOOR ROOF SEALANT 4. THE SUBMISSION OF A BID OR PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT THE ph 805.540.5240 <br /> 5- MINIMUM PRESSURE REQUIRED AT FIXTURE: 20.0 PSI,THEREFORE, OK. CONTRACTOR HAS FAMILIARIZED HIMSELF/HERSELF WITH THE PIANS AND BUILDING SITE. CLAIMS fax 805.540.5241 <br /> MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND/OR LABOR DUE TO DIFFICULTIES www.LHBassoc.com <br /> CRITERIA: ENCOUNTERED WILL NOT BE RECOGNIZED UNLESS THESE DIFFICULTIES COULD NOT HAVE BEEN <br /> -- FORESEEN, EVEN THOUGH PROPER EXAMINATION <br /> HAD BEEN MADE. <br /> �� - 1. BUILDING DEMAND, 9.5 WSFU 5, COORDINATE WITH ALL TRADES AND VERIFY ALL EQUIPMENT ROUGH-IN ITEMS AND LOCATIONS WITH <br /> 12"CW BELOW FLOOR 2. ELEVATION TO HIGHEST FIXTURE: 2 FEET THE EQUIPMENT SUPPLIER OR CONTRACTOR,ALL RE-WORK AND CORRECTIONS REQUIRED DUE IT PRD O <br /> 112"CW TO TRAP, I 3, TOTAL DEVELOPED PIPE LENGTH, 125 FEET FESS/ r1� <br /> 4 SYSTEM TYPE: LACK OF COORDINATION SHALL BE THE CONTRACTOR'S RESPONSIBILITY,AND DONE AT NO COST TO t�o �� S BFB `y( <br /> CONNECT AS REQ'D. PRESSURE ASSIST TANK THE OWNER <br /> NOTE: 5. METER SERVICE, 314 INCH <br /> �� �� 4O <br /> TE: ROOF VETS ARE NOT �� I ROOF CONSTRUCTION, 6 BUILDING SERVICE: 314 INCH 6. SUBMIT SIX COPIES OF SHOP DRAWINGS AND MATERIAL DATA SUBMITTALS 70 THE CHEVRON C7 X � x <br /> UNDERGROUND PIPING SHALL BE HARD ALLOWED WITHIN 1'-0" OF J .SEE ARCHITECTURAL SUBMIT <br /> ENGINEER, IF REQUESTED, FOR APPROVAL BEFORE INSTALLATION. NO E CHEVRON <br /> No. 78916 m <br /> DRAWN COPPER. ANY VERTICAL SURFACE DRAWINGS SHALL BE ALLOWED WITHOUT PRIOR APPROVAL BY THE ENGINEER. * exp. 03/18 <br /> 5 TRAP PRIMER R F VENT PIPE, SEE PLANS 7 SANITARY WASTE AND VENTS SHALL BE APPROVED PVC OR ABS PLASTIC PIPE AND FITTING, PER �9� clw4 _ <br /> 1 <br /> ROOF VENT ASTM D2661-89 OR D266,5-89. Ofi 0 <br /> SCALE: N.T.S- SCALE: N.T.S. 8. HOT AND COLD WATER AND INDIRECT WASTE PIPING SHALL BE HARD-DRAWN COPPER TUBE TYPE <br /> "L", PER ASTM BBS-88A, MADE UP WITH WROUGHT OR FORGED COPPER SWEAT FITTINGS. UNDER <br /> -2"x16GA. GALV. PLUMBING EQUIPMENT SCHEDULE SLAB PIPES SHALL BE TYPE"K"SOFT TEMPER COPPER TUBE WITHOUT JOINTS. SOLDER SHALL BE <br /> S M. STRAP LEAD-FREE, CANFIELD"100%WATERSAFE" <br /> THERMAL EXPANSION TANK UNISTRUT <br /> CONSULTANTS <br /> 9. VALVES: USE PIPE SIZE VALVES,AS SHOWN BELOW: <br /> P-100pT NO. DESCRIPTION W V CW HW REMARKS A. GATE: MILWAUKEE 148 OR 149 <br /> HW CHANNEL, <br /> _ _ B, CHECK- MILWAUKEE 509T OR 1509T <br /> C. PRESSURE AND TEMPERATURE RELIEF VALVES WATTS TYPE 100XL. <br /> WATERHOT SUPPLY BOLT TO WALL - -- - ' <br /> �' MODEL: ZURN FD-2322-NH2-P, PROVIDE PRECISION PLUMBING PRODUCTS INC, PRIME <br /> OUTLET, SEE PLANS W STRUCTURE FD 1 FLOOR DRAIN 2" 1 112 - RITE TRAP PRIMER VALVE WITH FLUSH MOUNT METAL ACCESS DOOR <br /> THREADED TEE WITH REMOVABLE CAP WITH(2)31$" 10. FIXTURE TAILPIECES AND TRAPS FOR LAVATORIES AND SINKS SHALL BE BRASS TUBING,SEMI-CAST, <br /> TYPICAL HVAC COLD WATER-- BOLTS, MIN. --- <br /> OR CAST IRON;ALL BRASS TUBING SHALL BE 17 GAGE, CHROME PLATED. <br /> MODEL: ZURN FD2376 WITH HALF GRATE <br /> SUPPLY INLET, SFE P1458 BRACKET, FS 1 �LOOR SINK 11. ALL PPE HANGERS, CLAMPS AND CHANNELS SHALL BE ADEQUATELY SIZED TO CARRY PIPE LOADS <br /> PLANS ° <br /> ANDNUTS,NU BOLTS - NOTED: NOTED,D DESCRIPTION. INDIRECT WASTO�pRAi1 L CAST IRON BODY WITH ACID RESISTANT PORCELAIN ENAMEL COATING FLOOR AND <br /> SHUT-OFF VALVES -- " INTALL TOP OF SINK RIM FLUSH WITH FINISH FLOOR SURFACE. AND PREVENT SAGGING. <br /> VENT TYPICAL OF 2 - <br /> 12. INSULATE ALL HOT WATER PIPING WITH OWENS CORNING TYPE ASJ/SSL-II HEAVY DENSITY FIBER <br /> PLACES MODEL: AMERICAN STANDARD❑REAR OVERFLOW, <br /> GLASS WITH ALL SERVICE JACKET; 112"FOR RUNOUTS UP TO 12', 1"FOR OTHER PIPING 2"OR LESS IN <br /> DESCRIPTION: WALL HUNG LAVATORY, REAR OVERFLOW, SOAP DEPRESSION, FAUCET HOLES ON 4"CENTERS. <br /> 112" LAV-1 LAVATORYPROVIDE TOTO TEL105 SERIES SELF-METERING,THERMOSTATIC FAUCET WITH A FLOW RATE NOT DIAMETER. INSULATION SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE <br /> SLOPE 118"PER 2 1 112 112 1/2" EXCEED 0.20 GALLONS PER CYCLE, MIXING VALVE SHALL 8E 5ET TO 11fl°F- PROVIDE FAUCET DECK DENSITY NOT TO EXCEED 50 WHEN TESTED IN ACCORDANCE WITH U-B.C.STANDARD 42-1. <br /> FOOT DOWN!N UNION OR APPROVED�- ASME PRESSURE& PLATE <br /> DIRECTION OF FLOW FLEX CONNECTOR, /� TEMPERATURE RELIEF <br /> ACCESSORIES: HANDY_SHIELD#2003 TRAP AND SUPPLY INSULATION 13. ALL OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE AND <br /> 2"MIN. <br /> TYPICAL OF 3 VALVE <br /> NEOPRENE ' 113 H FROM TOP __ ....._.._. <br /> PROPER <br /> - <br /> INSTALLATION OF THE WORK OF THIS SECTION,SHALL BE NEW, FIRST QUALITY OF THEIR <br /> RESPECTIVE KINDS,AND AS SELECTED BY THE CONTRACTOR SUBJECT TO ACCEPTANCE BY THE <br /> TUBING WITH OF THE TANK - - ENGINEER. <br /> MODEL: TURBOAIR-GREEN WORLD#TSA 3 14-D1 <br /> S.S. CLAMPS 5"MIN P DESCRIPTION: THREE COMPARTMENT SINK, 18 GAUGE 304 STAINLESS STEEL WITH 18"LEFT AND <br /> RD-l! THREE COMPARTMENT SINK 1 112" 112` 112" RIGHT HAND DRAINBOARDS, 18 x 18'x 14"SINK COMPARTMENTS WITH 11"HIGH 14. LAY OUT THE PLUMBING SYSTEM IN CAREFUL COORDINATION WITH THE DRAWINGS, DETERMINING <br /> BACKSPLASH. 8"CENTER GOOSENECK FAUCET CONTROLLED BY MIXING PROPER ELEVATIONS FOR ALL COMPONENTS OF THE SYSTEM AND USING ONLY THE MINIMUM <br /> COPPER DRAIN TEMPERING VALVE SET TO 120°F(ASSE 1070 OR CSA B125.3)WITH 0-4 GPM FLOW NUMBER OF BENDS TO PRODUCE A SATISFACTORILY FUNCTIONING SYSTEM. FOLLOW THE GENERAL <br /> HOSE 8fB DRAINRATE, 18 GA.PER CODE GUARD AT RIGHT WME ITH HEROUNDED CORNERD P-TRAP UNLTH ESS <br /> INDIRECT DRAIN. 6"HIGH SPLASH LAYOUT SHOWN ON THE DRAWINGS IN ALL CASES EXCEPT WHERE OTHER WORK MAY INTERFERE, REVISIONS <br /> VALVE BEYOND UNLESS SHOWN OTHERWISE, LAYOUT ALL PIPES TO FALL WTHIN PARTITION, WALL, FLOOR, OR <br /> ROOF CAVITIES,AND DO NOT REQUIRE FURRING OTHER THAN AS SHOWN ON THE DRAWINGS. <br /> ROOF JACK PROVIDE 2"BEND <br /> IN STRAP WITH <br /> 15. DO NOT CUT INTO OR REDUCE THE SIZE OF ANY LOAD-CARRYING MEMBER WITHOUT THE PRIOR <br /> 2 SMS INTO -_ - __ -_ <br /> ... <br /> - AL OF THE ARCHITECT INSTALL ALL PIPES TO CLEAR ALL BEAMS AND OBSTRUCTIONS- <br /> _...... <br /> MODEL: TURBOAIR-GREEN WORLD#TSA-3-14-D1 <br /> METAL BACKING DESCRIPTION: THREE COMPARTMENT SINK, 18 GAUGE 304 STAINLESS STEEL WITH 18"-LEFT AND <br /> 6- UNLESS SHOWN OTHERWISE, PROVIDE UNIFORM PITCH OF AT LEAST 114 INCH PER FOOT FOR ALL <br /> S-1 THREE COMPARTMENT SINK 1I2" 112" 112' RIGHT HAND DRAfNBOARDS, 18"x 18"x 14"SINK COMPARTMENTS WITH 177"HIGH <br /> DRAINAGE PIPING WITHIN THE BUILDING. <br /> CONDENSATE DRAIN THROUGH �y 3"x14 GA. PLATE BACKSPLASH 8"CENTER GOOSENECK FAUCET CONTROLLED BY MIXING <br /> ROOF TO MOP SINK AS STRAP TEMPERING VALVE SET TO 120° F(ASSE 1070 OR CSA 8125,3)WITH 0.4 GPM FLOW 17. EXTEND ALL PLUMBING VENTS ABOVE ROOF TO PARAPET HEIGHT. SEE DETAIL 1 THIS SHEET. <br /> INDICATED e <br /> RATE, 18 GA,CHROME PLATED ROUNDED <br /> WITH INDIRECT DRAIN,6"HIGH SPLASH 18. PROVIDE PRESSURE REDUCING VALVE IF WATER SERVICE PRESSURE EXCEEDS 80 psi PROVIDE PROVIDE DRAIN NUT IN BOTTOM OF P-TRAP. GUARD AT RIGHT SIDE,WITH ROUND/ D CORNER <br /> L2x2x16 GA. x U-3"CLIP _ _ ."`. _ _ _ <br /> MODEL. ELKAY SSP,#EMS-14X ECONOMY SERIES 14"SINK --- ........ BOOSTING SYSTEMPROVIDE <br /> ANGLES WITH (3}#10 - <br /> IF PRESSURE IS BELOW 35 P51. <br /> GALV. S.M. PAN SMS INTO PLATFORM S-2 ' AND SINKDESCRIPTION- 18 GAUGE, 300 SERIES STAINLESS STEEL,6"BACKSPLASH WITH 2"RETURN, GOOSE 19. PROVIDE SHUT-OFF GATE VALVES AND UNIONS AT ALL WATER CONNECTIONS TOE UPMFNTAND SUBMITTAL DATES <br /> CONDENSATE TRAP PLATE ��� 2 1 112 1!2 1/2" NECK FAUCET AND WALL MOUNT BRACKET. PROVIDE SIDE SPALSHES AND FAUCET <br /> APPLIANCES- PROVIDE STOPS AND CHROME PLATED BRASS SUPPLIES AT THE FIXTURES- <br /> SHELF&SHELF --� -TYPICAL{4)LOCATIONS UPGRADE <br /> SUPPORT, SEE � � �`-. <br /> - 20. ISOLATE ALL DISSIMILAR METALS WITH"EPCO"DIELECTRIC OWNER. <br /> DETAIL 3/P0.1 COPPER DRAIN LECTRIC UNION EXCEPT FOR BRAS <br /> S, E 5 OR BRONZE Q3129/2016 <br /> _ VALVES WITH STEEL PIPE. <br /> MODEL: SSP INC. MODEL#FLR-3 <br /> PIPE, EXTEND TO � ' REG. AGENCIES <br /> S 3 SERVICE MOP SINK (E)3" (E)2" (E) 112 (E)112 DESCRIPTION 12"DEEP WITH KOHLER FAUCET MODEL#K-8907 <br /> MOP SINK BELOW 21. PROTECT THE POTABLE WATER SUPPLY AGAINST BACKFLOW AND SIPHONAGE FROM EQUIPMENT, <br /> ACCESSORIES ATMOSPHERIC VACUUM BREAKER AND 3"-RAIN <br /> ........ <br /> SING APPROVED BACKFLOW AND ANTI SIPHON DEVICES, <br /> I E5. O.T.B.: <br /> MODEL. KOHLER"HIGHLINE"#K-3519-T <br /> WC-1 WATER CLOSET 4" 3-112" 112" DESCRIPTION: ADA COMPLIANT,VIT. CHINA, 17-118"HIGH ELONGATED BOWL; PRESSURE ASSIST FLUSH VALVE, 22. THOROUGHLY CLEAN ALL PIPING AND EQUIPMENT, REMOVING ALL DIRT, RUST, OIL AND PLASTER. <br /> (FLOOR MOUNT) TANK COVER LOCKS; 1.0 GPF- PROVIDE#K-4650 WHITE OPEN FRONT SEAT AND ANGLE SUPPLY <br /> WITH STOP. VERIFY FLUSH VALVE VIDE#K-46 REQUIRED FOR ADA T SEATED AN PRIOR TO 23. TEST SANITARY AND PROCESS PIPING BY PLUGGING ALL OPENINGS AND FILLING WITH WATER TO A PROJECT NO. <br /> ORDERING HEIGHT EQUAL TOA 10 FOOT HEAD.ALLOW TO STAND ONE HOUR OR LONGER AS REQUIRED. <br /> - REPAIR LEAKING JOINTS AND THEN RE-TEST. 15-13-001 <br /> MODEL. AO SMITH DEL-30 - <br /> ....................... <br /> WH-1 WATER HEATER 3I4" 3I4" DESCRIPTION. 30 GALLON, RECOVERY 49 GPH @ 100°RISE,6KW16KW SIMULTANEOUS OPERATION 24. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN INSPECTED AND ACCEPTED 8Y THE LOCAL DRAWN BY; <br /> ELECTRICAL 12KW,240V13PH <br /> --_ _ _........ AUTHORITY AND THE ENGINEER <br /> - _ CHECKED BY: <br /> WATER H FATE R <br /> AFS <br /> 25. TEST WATER LINES AT 100 PSIG, RETAIN FOR 24 HOURS;REPAIR ALL LEAKS AND RE-TEST. <br /> JRB <br /> GROSS-CONNECTION TESTING SHALL BE INCLUDED PER UPC J8 OF APPENDIX J. <br /> MODEL: ZURN#Z-1400-HD <br /> 26. THE ENTIRE SYSTEM SHALL BE WARRANTED FOR A PERIOD OF ONE(1)YEAR BEGINNING WITH <br /> COTG CLEANOUT TO GRADE ACCEPTANCE OF THE WORK.ALL LABOR AND MATERIAL NECESSARY TO REPAIR OR REPLACE THE <br /> ELECTRIC WATER HEATER WHERE CLEAN OUT OCCURS AT FINISH GRADE, PROVIDE PRECAST CONCRETE YARD BOX SYSTEM, OR PORTIONS THEREOF, DURING THAT TIME SHAAL BE WARRANTED FOR A PERIOD OF ONE <br /> WHERE CLEAN OUT OCCURS AT PAVING, PROVIDE TRAFFIC RATED BOX (1)YEAR FROM THE REPAIR OR REPLACEMENT. <br /> -_ <br /> - <br /> MODEL: ZURN#ZN-1400-BP, <br /> FCO FLOOR CLEANOUT <br /> BOTTOM OF CEILINGIROOF DECK-- <br /> 27. PROVIDE ONE REPRODUCIBLE(SEPIA)AS-BUILT DRAWING. <br /> SEISMIC ANCHOR STRAPS AT POINTS - <br /> -- <br /> VERTICAL CEILING TILE ------ 28 <br /> WITHIN THE UPPER AND LOWER . - <br /> FURNISH ACCESS DOORS AND PANELS AT WALLS AND CEILINGS FOR ACCESS TO HARDWARES, <br /> MODEL: ZURN#Z-1446 CONTROLS,OPERATOR, DRIVE MECHANISMS,TEMPERING VALVES,TRAP PRIMERS AND SHUT-OFF <br /> ONE-THIRD OF ITS VERTICAL DIMENSION WCO WALL CLEANOUT VALVES. <br /> f� <br /> 3"x14 GA. PLATE STRAP <br /> 4"DEEP 20 GA. GALVANIZED - <br /> 23. PRIOR TO USE,STERILIZE THE ENTIRE WATER SYSTEM WITH CHLORINE PER SECTION 609 9 OF W <br /> BOTTOM OF CEILING PANELS- WHA WATER HAMMER ARRESTOR <br /> MODEL: ZURN#1250 XL CALIFORNIA PLUMBING CODE. W <br /> SOLDERED DRAINPAN DESCRIPTION: LEAD FREE PRESSURE SURGE ARRESTOR Q <br /> 112"O THREADED HANGER ROD WITH <br /> PROVIDE AN OUTLET 2 PPE SIZES <br /> LARGER THAN T&P VALVE <br /> DOUBLE NUT AND WASHER _...._ <br /> U � Z <br /> -HEM TO EDGE OF PAN <br /> MODEL: PPP#PR50p-2 PRIMERITE, PROVIDE 12"x 12"METAL ACCESS PANEL WITH LOCK, <br /> W Zo <br /> - <br /> PROVIDE C6xS-2 CEILING RAFTER OR -EXTEND 314"DRAIN LINE TO MOP TP-1 TRAP PRIMER 112" <br /> APPROVED ALTERNATE METHOD OF SINK SEE DETAIL 5 THIS SHEET <br /> UPPER ATTACHMENT <br /> 2.. -- - J <br /> ...... . ..... ....... <br /> .. <br /> .. ....... . <br /> Z � Q <br /> TYP. � 24"x24"x23/32"PLYWOOD PLATFORM - - - -- U <br /> Q FLOOR DECK <br /> L2x2x114 WELDED ANGLE FRAME(WITH � -ATTACH TO ANGLE FRAME WITH O Q <br /> SMOOTH ROUNDED EDGES)BOLTED TO CJ #12 SMS AT 6"O.C. CIS U <br /> 4x6 WOOD BLOCKING WITH (2)314" W <br /> DIAMETER LAG BOLTS r` <br /> ALTERNATE:#12 SMS AT 6"O.C. MAXIMUM CD <br /> dam' z <br /> (3 SCREWS MINIMUM)INTO METAL z Q <br /> r <br /> BACKING -MOP SINK MATERIALS FOR WATER, DRAIN , WASTE VENT PIP 2 <br /> FINISHED FLOOR , E AND D FITTINGS LEGEND <br /> G E N D <br /> ABOVEGROUND UNDERGROUND UNDERGROUND ABOVEGROUND -� <br /> %0 <br /> MATERIAL WATER PIPE AND WATER PIPE AND DRAIN,WASTE, DRAIN,WASTE, BUILDING SEWER REFERENCE REFERENCE SYMBOL ABBREVIATION DESCRIPTION <br /> -- FITTINGS FITTINGS VENT PIPE AND VENT PIPE AND PIPE AND STANDARD(S) STANDARD(S) <br /> FITTINGS FITTINGS FITTINGS PIPE FITTINGS <br /> W WASTE PIPE <br /> ASTM D 1527, ASTM D 2651, V VENT PIPE <br /> 3 WATER HEATER ELEVATION ABS(SCHEDULE 41}} • • • ASTM D 2661, ASTM D 2680' Cw CW COLD WATER PIPE <br /> ASTM F 29 , iiw HW HOT WATER PIPE <br /> ASTM F628 SHEET TITLE <br /> SCALE N.T.S. <br /> FIN FW FILTI RD WATER PIPE <br /> ASTM F 891, IMF IMF REDUCED SCALE WATER PIPE m <br /> CO-EXTRUDED PVC(SCHEDULE 40) ASTM D 2665, o <br /> • • • ASTM F 1488 ASTM F 794* SHUT OFF VALVE c2 <br /> ASTM F1866 r�%�� <br /> WCO WALL CLEANOUT � PLUMBING <br /> ASTM B 75, ASME B16-23 FCO FLOOR CLEANOUT <br /> COPPER(TYPE DWV) • • ASTM B 251, ASME 1316,29 SCHEDULE <br /> ASTM B 302, COTG CLEANOUT TO GRADE Q <br /> 1 ASTM B 306 c - HB H06F BIBB AND DETAILS <br /> TYPE K COPPER • ; <br /> ASTM B-88 ASTM B-88 <br /> AFF ABOVE FINISHED FLOOR HW HOT WATER o <br /> TYPE L COPPER . AFG ABOVE FINISHED GRADE IE INVERT ELEVATION O <br /> ASTM 8-88 ASTM 6-88 CD CONDENSATE DRAIN IMF ICE MAKER FEEDER <br /> M <br /> COTG CLEANOUT TO GRADE (N) NEW o <br /> PVC(SCHEDULE 40) • ASTM D 1785, ASTM D 2665, CW COLD WATER NTS NOT TO SCALE <br /> • ASTM D 2655, ASTM F 794', U <br /> ASTM F 794" ASTM F 1866 DWV DRAIN, WASTE,AND VENT SS SANITARY SEWER <br /> STAINLESS STEEL 304 <br /> DN DOWN TYP TYPICAL v SHEET NO. <br /> • (E) EXISTING VTR VENT THROUGH ROOF m <br /> ASME A112.3.1 ASME A112.3.1 � <br /> FCO FLOOR CLEANOUT WCO WALL CLEANOUT-STAo <br /> FW P1 � 1 <br /> INLESS STEEL 316L • . FILTERED WATER <br /> ASME A112.3,1 ASME A112,3.1 a <br /> 'FOR BUILDING SEWER APPLICATIONS, <br /> UNDER BUILDING SLAB,WITHOUT JOINTS m <br />