My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
2900
>
1600 - Food Program
>
PR0545112
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2020 8:39:00 AM
Creation date
4/17/2020 8:36:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0545112
PE
1635
FACILITY_ID
FA0025660
FACILITY_NAME
TASTEE THAI #87753T2
STREET_NUMBER
2900
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
14310020
CURRENT_STATUS
01
SITE_LOCATION
2900 E HARDING WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SShih
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATA SHEET <br /> ANSUL <br />i <br />R-102 Restaurant <br />Fire Suppression <br />Systems <br />Features <br />Low pH Agent <br />Proven Design <br />Reliable Gas Cartridge Operation <br />Aesthetically Appealing <br />UL Listed — Meets Requirements of UL 300 <br />ULC Listed — Meets Requirements of ULC/ORD-C1254.6 <br />CE Marked <br />Application <br />The ANSULo R-102 Restaurant Fire Suppression System is an <br />automatic, pre-engineered, fire suppression system designed <br />to protect areas associated with ventilating equipment includ- <br />ing hoods, ducts, plenums, and filters. The system also protects <br />auxiliary grease extraction equipment and cooking equipment <br />such as fryers; griddles and range tops; upright, natural charcoal, <br />or chain-type broilers; electric, lava rock, mesquite, or gas-radiant <br />char-broilers; and woks. <br />The system is ideally suitable for use in restaurants, hospitals, <br />nursing homes, hotels, schools, airports, and other similar facilities. <br />Use of the R-102 system is limited to indoor applications or loca- <br />tions that provide weatherproof protection within tested tempera- <br />ture limitations. The regulated release and tank assemblies must <br />be mounted in an area where the air temperature will not fall <br />below 32 °F (0 °C) or exceed 130 °F (54 °C). The system must be <br />designed and installed within the guidelines of the UUULC Listed <br />Design, Installation, Recharge, and Maintenance Manual. <br />System Description <br />The restaurant fire suppression system is a pre-engineered, wet <br />chemical, cartridge-operated, regulated pressure type with a fixed <br />nozzle agent distribution network. It is listed with Underwriters <br />Laboratories, Inc. (UUULC). <br />004215 <br />The system is capable of automatic detection and actuation <br />as well as remote manual actuation. Additional equipment is <br />available for building fire alarm panel connections, electrical <br />shutdown and/or interface, and mechanical or electrical gas line <br />shut-off applications. <br />The detection portion of the fire suppression system allows for <br />automatic detection by means of specific temperature-rated alloy <br />type fusible links, which separate when the temperature exceeds <br />the rating of the link, allowing the regulated release to actuate. <br />A system owner's guide is available containing basic information <br />pertaining to system operation and maintenance. A detailed tech- <br />nical manual, including system description, design, installation, <br />recharge and resetting instructions, and maintenance procedures, <br />is available to qualified individuals. <br />The system is installed and serviced by authorized distributors <br />that are trained by the manufacturer. <br />The basic system consists of an AUTOMAN regulated release <br />assembly which includes a regulated release mechanism and <br />a wet chemical storage tank housed within a single enclosure. <br />Nozzles with blow-off caps, detectors, cartridges, agent, fusible <br />links, and pulley elbows are supplied in separate packages in the <br />quantities needed for fire suppression system arrangements. <br />Additional equipment includes a remote manual pull station(s), <br />mechanical and electrical gas valves, and electrical switches for <br />automatic equipment and gas line shut-off. Accessories can be <br />added such as alarms, warning lights, etc., to installations where <br />required. <br />Additional tanks and corresponding equipment can be used in <br />multiple arrangements to allow for larger hazard coverage. Each <br />tank is limited to a listed maximum amount of flow numbers. <br />Vico <br />Fire Protection Products <br />One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com <br />Copyright © 2013Tyco Fire Products LP. / All rights reserved. / Form No. F-2004004-08