Laserfiche WebLink
!IV %TC <br /> A S S O C I A T E S I N C <br /> In July 1994, a RESNA field geologist observed the drilling of four additional groundwater <br /> monitoring wells (MW4, MW5, MW6, and MW7) at the site to further characterize subsurface <br /> conditions Groundwater samples collected from these additional wells contained no detectable <br /> petroleum hydrocarbons A detailed discussion of the Phase II Subsurface Investigation can be <br /> found in RESNA's "Summary Report, July 1994 Investigation,"dated August 26, 1994 <br /> In PHS/EHD correspondence dated March 1995, regulatory approval was given to sample wells <br /> MW3 and MWS and wells MW4, MW6 and MW7 on an alternating semi-annual basis MW1 <br /> and MW2 were to be sampled every quarter, conditions permitting <br /> To further evaluate the extent of residual soil contamination in the vicinity of the former <br /> underground fuel storage tank (UST), Smith Technology supervised the advancement of four soil <br /> borings (SB-1, SB-2, SB-3, and SB-4) on February 29, 1996 to depths of approximately 16 to 26 <br /> feet bgs Total petroleum hydrocarbons as gasoline (TPHg), benzene, toluene, ethylbenzene, and <br /> xylenes (BTEX) were detected above method detection limits at low to moderate concentrations <br /> in samples collected at depths between 10 and 15 feet bgs in borings SB-1, SB-2, and SB-3 A <br /> detailed discussion of this subsurface investigation can be found in Smith Technology's <br /> "Subsurface Investigation Report, " dated April 30, 1996 <br /> GROUNDWATER MONITORING AND SAMPLING <br /> ATC personnel performed groundwater monitoring and sampling on December 10, 1998 Field <br /> work consisted of measuring the depth-to-water in wells MW1 through MW7, using an <br /> electronic water/product interface probe to determine if free product was present, purging and <br /> sampling wells MW1, MW2, MW3 and MWS, and servicing the passive skimmer placed in well <br /> MW2 <br /> Static groundwater elevations were measured in each monitoring well on December 10, 1998 <br /> Groundwater was measured at an average of approximately 1168 feet bgs A groundwater <br /> gradient map was created with the December 10, 1998 data using a computer kriging program <br /> The gradient map, presented as Figure 2, depicts a southerly groundwater gradient averaging <br /> 0 007 ft/ft or approximately 37 feet/mile The water table elevation has increased an average of <br /> 0 64 feet since the previous measurements were collected in September 1998 Groundwater <br /> monitoring data are summarized in Table 1 <br /> On December 10, 1998, groundwater samples were collected by ATC from monitoring wells <br /> MW1, MW2, MW3, and MW5 Groundwater samples were collected from the monitoring wells <br /> after stabilization of pH, electrical conductivity (EC), and temperature All wells monitored were <br /> purged and sampled according to Smith Technology's Quality Assurance/Quality Control Plan <br /> on file with the PHS/EHD A minimum of five casing volumes of water were removed from <br /> each sampled well A dedicated disposable bailer was used to collect each water sample Purge <br /> water was discharged to the sanitary sewer under permit Field parameters and purged volumes <br /> are shown on well purge logs included in Attachment I <br /> 625811QUARTLYI4QR-1998 DOC 2 <br />