Laserfiche WebLink
1 Clayton <br /> LROUP SERVICES <br /> 62 Levels of Protection Available or Used <br /> A B C XX D XX <br />' <br /> Modifications/Additions- <br /> Dust filters may be utilized initially along with Level D PPE Monitor soil/media with PID or <br /> other organic vapor analyzers Use gloves to protect against dermal exposure <br />' 6.3 Air Monitoring Guidelines <br />' Device Action Level Action to be Taken <br /> Photovac-micro tip 25 ppm * Personnel will don half-face <br /> (OVA) respirators w/organic vapor <br /> cartridges <br /> * Above background, in breathing zone, stable for 5 nvnutes <br /> Comments: NA <br /> 6.4 Measures To Control Offsite Migration & Exposure <br /> Not a factor at this time <br /> 65 Special Site Considerations <br /> The operations area will have heavy equipment working nearby Be aware of any vehicle and <br /> heavy equipment traffic Operations will be conducted only during normal working hours <br />' 7.0 FIELD ACTIVITIES <br />' 7.1 Site Entry and Setup <br /> Initial level of protection: D <br /> I tions. Respiratory protection in accordance with section 6 3 <br /> Modifica p ry p � upgrade to level C if <br /> needed <br /> Special Procedures, Precautions, Equipment: NIA <br /> 'I <br />' S 1£S\Proj1P02263V263 hsp_Oc[02 doc <br /> A-10 <br /> 1 <br />