My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005947
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
2711
>
3500 - Local Oversight Program
>
PR0545605
>
ARCHIVED REPORTS_XR0005947
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2020 2:12:34 AM
Creation date
4/17/2020 4:15:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005947
RECORD_ID
PR0545605
PE
3528
FACILITY_ID
FA0003793
FACILITY_NAME
LEARNER COMPANY, THE
STREET_NUMBER
2711
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
14503009
CURRENT_STATUS
02
SITE_LOCATION
2711 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' k'q KLFINFELDER <br /> 2 Approximately one week to one month prior to conducting the sampling, the residual <br /> pressures at the air-Iine of each lysimeter are measured and the vacuum reset to <br />' manufactured recommended value (usually 50 centibars) The measurements and applied <br /> vacuums are noted on a sampling log form Kleinfelder has found that resetting the <br /> lysimeters vacuums before the sampling yields good sample recovery <br />' 3 The residual pressures are measured dust prior to collecting the sample The water line is <br /> then opened and nitrogen gas applied to the air line until either fluid or air is discharged <br /> 1 (for dry lysimeters) The sample is contained in a 1 liter unpreserved bottle and the <br /> volume recovered is estimated The fluid is then poured into appropriate preserved or <br /> unpreserved bottles of the requested analysis <br /> 4 After the sample is collected, the lysimeter vacuum is reset to the manufacturer's <br /> recommended value The lysimeter is also tested to evaluate potential leaks that may <br />' cause vacuum pressure loss <br />' A-6 Leachate Monitoring <br /> I The leachate riser or wells are first opened and allowed to equilibrate with the <br /> atmosphere <br /> 2 The leachate elevation is then measured from a set location using a conductivity-based <br /> water-level meter The level is generally measured from a surveyed mark on the north <br /> rim of the casing <br />' 3 A leachate sample is then collected using a clean, disposable bailer <br />' 4 The sample is labeled and immediately stored in an iced cooler pending transport to the <br /> analytical laboratory The sample is logged on a chain-of-custody <br /> A-7 Surface Water Monitoring <br />' 1 Prior to collecting surface water samples, the depth of water is estimated at a designated <br /> location in the surface water body <br /> I 2 Surface water samples are collected directly from the stream or surface water using a <br /> clean unpreserved plastic bottle, disposable bailer, bailer, coliwasa, DipstikTM, dipper, <br /> peristaltic pump, etc , or by directly filling the sample containers Sampling equipment <br />' will either be disposable, dedicated or decontaminated in accordance with the above- <br /> defined decontamination protocols Care is taken not to disturb the stream bottom and <br /> introduce sediment in the sample The fluid is then poured into appropriate preserved or <br /> unpreserved bottles for the requested analysis <br /> 20-2322-05 E01/20118061 Page A-7 <br /> Copyright 2001,Klemfelder,Inc January 12,2001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.