' k'q KLFINFELDER <br /> 2 Approximately one week to one month prior to conducting the sampling, the residual <br /> pressures at the air-Iine of each lysimeter are measured and the vacuum reset to <br />' manufactured recommended value (usually 50 centibars) The measurements and applied <br /> vacuums are noted on a sampling log form Kleinfelder has found that resetting the <br /> lysimeters vacuums before the sampling yields good sample recovery <br />' 3 The residual pressures are measured dust prior to collecting the sample The water line is <br /> then opened and nitrogen gas applied to the air line until either fluid or air is discharged <br /> 1 (for dry lysimeters) The sample is contained in a 1 liter unpreserved bottle and the <br /> volume recovered is estimated The fluid is then poured into appropriate preserved or <br /> unpreserved bottles of the requested analysis <br /> 4 After the sample is collected, the lysimeter vacuum is reset to the manufacturer's <br /> recommended value The lysimeter is also tested to evaluate potential leaks that may <br />' cause vacuum pressure loss <br />' A-6 Leachate Monitoring <br /> I The leachate riser or wells are first opened and allowed to equilibrate with the <br /> atmosphere <br /> 2 The leachate elevation is then measured from a set location using a conductivity-based <br /> water-level meter The level is generally measured from a surveyed mark on the north <br /> rim of the casing <br />' 3 A leachate sample is then collected using a clean, disposable bailer <br />' 4 The sample is labeled and immediately stored in an iced cooler pending transport to the <br /> analytical laboratory The sample is logged on a chain-of-custody <br /> A-7 Surface Water Monitoring <br />' 1 Prior to collecting surface water samples, the depth of water is estimated at a designated <br /> location in the surface water body <br /> I 2 Surface water samples are collected directly from the stream or surface water using a <br /> clean unpreserved plastic bottle, disposable bailer, bailer, coliwasa, DipstikTM, dipper, <br /> peristaltic pump, etc , or by directly filling the sample containers Sampling equipment <br />' will either be disposable, dedicated or decontaminated in accordance with the above- <br /> defined decontamination protocols Care is taken not to disturb the stream bottom and <br /> introduce sediment in the sample The fluid is then poured into appropriate preserved or <br /> unpreserved bottles for the requested analysis <br /> 20-2322-05 E01/20118061 Page A-7 <br /> Copyright 2001,Klemfelder,Inc January 12,2001 <br />