<br /> ELECTRICAL SPECIFICATIONS ELECTRICAL LEGEND ELECTRICAL LEGEND
<br /> ELECTRICAL POWER DRAFTING NOTATIONS
<br /> GE=NERAL NOTES:
<br /> ALL LINE VOLTAGE WIRING IN CONDUIT, SEE GENERAL NOTES N## KEY NOTE, SEE SCHEDULE
<br /> 1. ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIA - TICKS=#OF#12 WIRE, SHORT= HOT, LONG = NEUTRAL, DOT=GROUND, I
<br /> CODE OF REGULATIONS, INCLUDING THE FOLLOWING: UNLESS NOTED OTHERWISE N## EQUIPMENT TAG, SEE SCHEDULE � CHANGE EXISTING
<br /> TITLE 24, CCR, PART 2, 2016 CBC
<br /> TITLE 24, CCR, PART 3, 2016 CEC
<br /> 120V OUTLET, +18"TO BOTTOM OF BOX C\ OUTLET TO DEDICATED (e}
<br /> TITLE 24,CCR, PART 4, 2016 CMG S= SIGN A
<br /> TITLE 24, CCR, PART 9, 2016 CFC REFERENCE TO A DETAIL VIEW"A"ON SHEET E-2 '
<br /> F= FLOOR E-2
<br /> ALL APPLICABLE LOCAL CODES. • GFI= GROUND FAULT INTERUPTER ALL
<br /> 2. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, ETC. COUNTER OUTLET NEW ELECTRICAL
<br /> REQUIRED TO CARRY ON AND COMPLETE THE WORK. PERMIT BY OWNER.
<br /> — — EXISTING ELECTRICAL OR DEMOLISHED WHERE NOTED `
<br /> .......ry ..._m.... _.. W W
<br /> QUADRUPLEX OUTLET z W W ti
<br /> co
<br /> 3. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND -
<br /> (e} (E) EXISTING DEVICE, TO REMAIN IN OPERATION (e) (j 7 CCC
<br /> PERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER HALF SWITCHED OUTLETS (e)OFFICE
<br /> EXECUTION AND COMPLETION OF ALL"ELECTRICAL WORK"WHETHER SPECIFICALLY V Z U)
<br /> O
<br /> HEREBY TO EMERGENCY SYSTEMS (r) (R) REMOVE DEVICE, KEEP REMAINDER OF CIRCUIT IN OPERATION NO WORK W = w
<br /> MENTIONED OR NOT;ALL AS INDICATED, SPECIFIED HEREIN, AND/OR IMPLIED T OUTLETS ON EME Z LLI
<br /> CARRY OUT THE APPARENT INTENT THEREOF. REPLACE PANEL (e) ' J 0) N rn
<br /> �\ DUCT SMOKE DETECTOR (RR} REMOVE, RELOCATE AND RECONNECT DEVICE ON EXISTING CIRCUIT, EXTEND CIRCUIT UPGRADING IT [� Q O ,
<br /> 4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS'
<br /> TO 15DA. ------ H -15 W U p N L
<br /> LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BLU
<br /> EAR THEIR LABEL JUCTION BOX \ HP-9 HP-25 27� O [�
<br /> STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY O
<br /> WHEREVER � .
<br /> FURNISHED BY THAT AGENCY.
<br /> \\ff MOTOR 1 DISCONNECT (e)
<br /> .Wj " O c
<br /> LU 'r. v
<br /> 5. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE PANELBOARD (e) MAIN SERVICE LOAD CALCULArMENT LOAD= 81455W (e)PANEL HP (e) GFI \ Zw UE UIPMENTARE SHOWN TO SCALE WHEREVER POSSIBLE, — -- --------- _-- ORIGINAL APARTMENT (e} e `- COUNTERTOP
<br /> AND LOCATIONS OF Q \ T.
<br /> CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY TRANSFORMER/SWITCHBOARD A5 NOTED -- 1 NEW HOUSE/CAFE PANEL=23693 W (e)POS Al ( GFI GRINDER W I„• 0 �` a
<br /> THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT I I TOTAL= 105,41 8 W =439A ON 800A GFI OUTLET \
<br /> 10
<br /> AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES. I
<br /> (e)800A- 12D1240V BUS l
<br /> UC REF 1, U) V u
<br /> COMMUNICATIONS I I p Y
<br /> 6. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN UNLESS OTHERWISE TELEPHONE BACKBOARD, PROVIDE#8 GND TO SERVICE GROUND NEW ESPRESSO MAKER
<br /> M _ 1 REUSE DEDICATED �_ Z
<br /> GFI o
<br /> NOTED OR REQUIRED BY CODE. \ -
<br /> } I (e} CIRCUIT HP-30 FOR 30A/240V OUTLET 0 N E a
<br /> 7, THE OWNER RESERVES THE RIGHT TO
<br /> RELOCATE ALL LIGHTING, OUTLETS AND COMMUNICATIONS OUTLET, PHONE & DATA I (e)100 l _,,/OPEN DELI CASE (e) U N
<br /> SWITCHES BEFORE THEY ARE ROUGHED IN AT NO EXTRA COST. \ PHONE ONLY OUTLET, PREWIRED WITH CAT 5e CABLE I I REPLACE WITH \�
<br /> 2 I 150A/2 METER H
<br /> & OUTLET P-29131
<br /> WIRING METHODS: DATA ONLY OUTLET JACK, PREWIRED WITH CAT 6 CABLE
<br /> �— -------- ,-- USE EXISTING COUNTER
<br /> —.---------� #10 (e) OUTLET FOR COFFEE 7F,
<br /> 1. ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS, CONCEALED IN WALL AND --- (e)GROUND (e)
<br /> BLENDER
<br /> CEILING U.O.N. MOUNTING HEIGHTS FINISHED CEILING (e) GFf_
<br /> ALARM APPLIANCE (e)1.5"C REPLACE FEEDER
<br /> AUDIBLE FIRE e
<br /> = GFI
<br /> 2. MINIMUM CONDUIT SIZE SHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS ARE Gp WITH 3#110+1#6 GND. m W ( )
<br /> A. GALVANIZED RIGID STEEL.. NOT LESS THEN 90"AFF OR AT
<br /> LEAST 6" BELOW CEILING
<br /> B. GALVANIZED STEEL EMT. ❑�
<br /> __..,. _.. .....
<br /> C. LIQUID TIGHT STEEL FLEX- FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. 1\
<br /> '�- USE EXIST DEDICATED �+ - REUSE EXISTING Cl
<br /> li RCUlT
<br /> D. FLEXIBLE STEEL CONDUIT- FOR INDOOR FINAL CONNECTIONS TO VISUAL APPLIANCE TO BE PANEL REPLACE WITH 150ACIRCUIT HP-42 FOR HP-22 FOR NEW ICE MACHINE z
<br /> MECHANICAL EQUIPMENT(NOT TO EXCEED 36"). NOT LESS THAN 80"AFF MIN, HP PANEL UG. REF COFFEE BREWER
<br /> J
<br /> E. PVC CONDUIT SCHEDULE 40, UNDERGROUND. AND NOT MORE THAN 96"AFF
<br /> � --
<br /> 3. NMC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING. 12"TYPICAL TO BOTTOM NOTE: ALL 120V OUTLETS IN THE 120/240V, 3W
<br /> 4. MC CABLING SYSTEMS IS ALLOWED IN THIS BUILDING.
<br /> ` - FIRE ALARM MANUAL FOOD PREP AREA ARE TO BE GFl
<br /> 51 naw
<br /> WIRING DEVICES: I PULL STATION SHALL NOT
<br /> SYSTEMS FURNITURE ` I REQUIRE "TIGHT GRASPING, J
<br /> UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS CONNECTIONS +15"TO I PINCHING OR TWISTING OF ARC FLASH LABELLING REQUIREMENT:
<br /> THE FOLLOWING LABEL ASA MINIMUM
<br /> BOTTOM OF BOXES - \ THE WRIST" PROVIDE
<br /> (BROWN, WHITE, GREY, BEIGE OR IVORY)AS SELECTED BY THE ARCHITECT: \ 4r
<br /> FOR COMPLIANCE WITH NFPA AND NEC ON 1 CONVIENCS OUTLETS, THIS PROJECT: ELECTRICAL PLAN
<br /> A. WIRING DEVICES LEV[TON# HUBBELL# P &S# PHON
<br /> SINGLE POLE SWITCH 1221 1221 20AC1 PHONE & DATA OUTLETS, \ ® � THERMOSTAT SCALE: 114" 1'-D"
<br /> 1223 1223 20AC3 +15"TO BOTTOM \ OR WALL PHONE Q DANGER
<br /> THREE WAY SWITCH OF BOX \
<br /> DUPLEX CONY. OUT. 15A 5262 5262 5262 LIGHT SWITCHES ARC FLASH AND SHOCK HAZARD
<br /> DUPLEX GFI CONY. OUT. GF5262 \v `� FOLLOW ALL REQUIREMENTS IN NFPA 70E iU
<br /> �� 48"TO TOP FOR SAFE WORK PRACTICES AND FOR
<br /> OF BOX PERSONAL PROTECTIVE EQUIPMENT ' f
<br /> DEVICE PLATES: FINISHED FLOOR W
<br /> w J
<br /> J
<br /> 1. ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED EQUAL r— Uj
<br /> UNLESS OTHERWISE NOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL BE RAISED 2 ~
<br /> METAL. Z ONE LINE DIAGRAM
<br /> SCALE: NTS
<br /> 2. DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2" RAISED STEEL PLATES.
<br /> WEATHERPROOF COVERS TO BE SNAP TYPE COVERS.
<br /> 3. DEVICE PLATES FOR TELEPHONE AND COMPUTER OUTLETS TO BE PROVIDED BY
<br /> OWNER'S VENDOR. ALL TELEPHONE AND COMPUTER SYSTEM WIRING BY OWNER'S
<br /> VENDOR. (e)PANEL HP
<br /> Location: Volts: 1201240 Single A.I.C. Rating: EXIST
<br /> SUPPORTS:
<br /> Mains Type:
<br /> Supply From: Phases: 1
<br /> i. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL Mounting: Recessed Wires: 3 Mains Rating: 100 A
<br /> ELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT. Enclosure: NEMA 1 MCB Rating: 100 A
<br /> 2. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO
<br /> METAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS Notes:
<br /> AND MACHINE SCREWS OR BOLTS. REPLACE PANEL AND UPGRADE WITH NEW 150 AMP PANEL
<br /> GROUNDING:
<br /> 0 t
<br /> 1
<br /> GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND
<br /> 1 1
<br /> SPECIFICALLY INCLUDING SWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC. CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT W
<br /> HP-1 (e)PARKING LOT LIGHTS 20 A 1 500 VA 360 VA 1 2D A (e)ROOF OUTLET HP-2 �
<br /> PANELBOARDS: — Lu U
<br /> HP-3 (e)CEF 20 A 1 252 VA 180 VA 1 20 A (e IRRIGATION HP-4Lu
<br /> HP-5 (e)STAIR LIGHTS 24 A 1 377SVA 104 VA 1 20 A (e)FACP HP-6 0 U
<br /> UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON Tcc
<br /> HE PANEL SCHEDULE, 20 A 1 540 UA, 360'VA 1 20 A (e)CASH REGISTER OUTLET HP-8 O Q °C
<br /> HP-7 (e)OUTLETS
<br /> WITH THE NUMBER AND SIZE OF BREAKERS INDICATED ON THE PANEL SCHEDULE. SINGLE 20 A 1 600.VA 360 VA 1 20 A (e PHONE _ HP-10 a
<br /> SHALL BE BOLT-ON TYPE. THE PANEL HP-9 NEW UC REF
<br /> POLE, TWO POLE AND THREE POLE BREAKERSHP-11 MICROWAVE 20 A 1 1000 VA' 6(];VA 1 20 A (e)CATV HP-12 ~ 0 x
<br /> DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKE AND HAVE 20 A 1 24D VA 600 VA 1 20 A e COFFEE HP-14 U
<br /> W z O � o �
<br /> HP-13 (e)CIRC PUMP w
<br /> TYPEWRITTEN DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICED BY ( ) HP-16
<br /> G SHALL BE COPPER. HP-15 Kitchen Equipment- Non-Dwelling Unit 20 A 1 600 VA OL
<br /> LU o O
<br /> EACH BREAKER, ALL BUSSING HP-17 (e)WATER HEATER 20 A 1 8¢IIA _ HP-18
<br /> HP-19O.VA 1 20 A SPARE HP-20
<br /> WORKING CLEARANCES FOR PANE=LS &SWITCHBOARDS HP-21 (e)CIRCUIT PUMP 20 A 1 240 VA =120Q VA 1 20 A ICE MACHINE HP-22
<br /> 1. COORDINATE WITH OTHER TRADES TO ENSURE CODE REQUIRED WORKING HP-23 (e)FIRE BELL 20 A 1 100 VA 300 VA i 20 A (e)LIGHTS HP-24
<br /> CLEARANCES, ACCESS, ETC. FOR PANELS AND SWITCHBOARDS PER C.E.C. SECTIONS HP-25 ESPRESSO 30 A 2 2400 VA 1080 VA 1 20 A (e)OUTLETS HP-26
<br /> 110-16 AND 384-4. HP-27 - -- -- 2400 VA 540 VA 1 20 A (e)OUTLETS
<br /> HP-28
<br /> HP-29 BREWER 30 A 2 2550 VA 600 UA 1 20 A DELI CASE
<br /> _ HP-3D STAMP
<br /> TESTING:
<br /> HP-31 -- -- -- 25501fA' S4Q VA .' 1 20 A (e)OUTLETS HP-32
<br /> HP 33 100 VA 1 20 A (e}RESTROOM HP-34
<br /> INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND HP-35 1204 VA 1 20 A (e.)FAN COIL HP-36 eR�F sloN
<br /> 1. THE ENTIRE ELECTRICAL �� R4 c
<br /> S. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND HP-37 1867 VA 2 30 A (e)CU HP-38 M��Fyc
<br /> IMPROPER GROUND __
<br /> GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHETHER SUCH HP_39 1867 VA - HP-4D y z
<br /> E FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED, HP-41 6Q4 VA 1 20 A NEW UC REF HP-42 `
<br /> TESTS INDICAT777
<br /> E � Exp.' 5�30�19
<br /> REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. Total Load: 13854 VA 12789 VA * P
<br /> I +
<br /> Total Amps: 115A 107 A -
<br /> OWNER AND THE ARCHITECT, THAT THE ENTIRE INSTALLATION II 'l4 �gr�ECTR tiCP���Q
<br /> 2. DEMONSTRATE TO THE end:
<br /> COMPLETE, IN PROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN Legend: f op-
<br /> is CAI�Fo
<br /> PROPERLY AND FULLY EXECUTED. PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS.
<br /> y r
<br /> Load Classification Connected Load Demand Factor Estimated Demand Panel TotalsM)
<br /> Kitchen Equipment- Non-Dwekling Unit 7500 VA 70,00% 5254 VA � A
<br /> DRAWN
<br /> RCS
<br /> Receptacle 7000 VA 90.00% 6300 VA Total Conn. Load: 26643 VA
<br /> Spare 12143 VA 100.00% 12143 VA Total Est. Demand: 23693 VA CHECKED
<br /> Total Conn.: 111 A RCS
<br /> Total Est. Demand: 99 A DATE
<br /> �_ 8/10/2018 1 1:54:45 AM
<br /> SCALE
<br /> _ - As indicated
<br /> Notes:
<br /> JOB
<br /> "SPARE" ARE EXISTING LOADS
<br /> 2D17.xxx
<br /> SHEET
<br /> C:\Users\RichardSmith\HCS ENGINEERINGIProjects-Documents\Add to 20181LeeJagoe UOP Cate1UOP CAFE ELECTRICAL.rvt
<br />
|