Laserfiche WebLink
REVISIONS BY <br /> ELECTRICAL SPECIFICATIONS ELECTRICAL LEGEND ELECTRICAL LEGEND <br /> ELECTRICAL POWER DRAFTING NOTATIONS <br /> GE=NERAL NOTES: <br /> ALL LINE VOLTAGE WIRING IN CONDUIT, SEE GENERAL NOTES N## KEY NOTE, SEE SCHEDULE <br /> 1. ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIA - TICKS=#OF#12 WIRE, SHORT= HOT, LONG = NEUTRAL, DOT=GROUND, I <br /> CODE OF REGULATIONS, INCLUDING THE FOLLOWING: UNLESS NOTED OTHERWISE N## EQUIPMENT TAG, SEE SCHEDULE � CHANGE EXISTING <br /> TITLE 24, CCR, PART 2, 2016 CBC <br /> TITLE 24, CCR, PART 3, 2016 CEC <br /> 120V OUTLET, +18"TO BOTTOM OF BOX C\ OUTLET TO DEDICATED (e} <br /> TITLE 24,CCR, PART 4, 2016 CMG S= SIGN A <br /> TITLE 24, CCR, PART 9, 2016 CFC REFERENCE TO A DETAIL VIEW"A"ON SHEET E-2 ' <br /> F= FLOOR E-2 <br /> ALL APPLICABLE LOCAL CODES. • GFI= GROUND FAULT INTERUPTER ALL <br /> 2. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, ETC. COUNTER OUTLET NEW ELECTRICAL <br /> REQUIRED TO CARRY ON AND COMPLETE THE WORK. PERMIT BY OWNER. <br /> — — EXISTING ELECTRICAL OR DEMOLISHED WHERE NOTED ` <br /> .......ry ..._m.... _.. W W <br /> QUADRUPLEX OUTLET z W W ti <br /> co <br /> 3. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND - <br /> (e} (E) EXISTING DEVICE, TO REMAIN IN OPERATION (e) (j 7 CCC <br /> PERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER HALF SWITCHED OUTLETS (e)OFFICE <br /> EXECUTION AND COMPLETION OF ALL"ELECTRICAL WORK"WHETHER SPECIFICALLY V Z U) <br /> O <br /> HEREBY TO EMERGENCY SYSTEMS (r) (R) REMOVE DEVICE, KEEP REMAINDER OF CIRCUIT IN OPERATION NO WORK W = w <br /> MENTIONED OR NOT;ALL AS INDICATED, SPECIFIED HEREIN, AND/OR IMPLIED T OUTLETS ON EME Z LLI <br /> CARRY OUT THE APPARENT INTENT THEREOF. REPLACE PANEL (e) ' J 0) N rn <br /> �\ DUCT SMOKE DETECTOR (RR} REMOVE, RELOCATE AND RECONNECT DEVICE ON EXISTING CIRCUIT, EXTEND CIRCUIT UPGRADING IT [� Q O , <br /> 4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS' <br /> TO 15DA. ------ H -15 W U p N L <br /> LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BLU <br /> EAR THEIR LABEL JUCTION BOX \ HP-9 HP-25 27� O [� <br /> STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY O <br /> WHEREVER � . <br /> FURNISHED BY THAT AGENCY. <br /> \\ff MOTOR 1 DISCONNECT (e) <br /> .Wj " O c <br /> LU 'r. v <br /> 5. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE PANELBOARD (e) MAIN SERVICE LOAD CALCULArMENT LOAD= 81455W (e)PANEL HP (e) GFI \ Zw UE UIPMENTARE SHOWN TO SCALE WHEREVER POSSIBLE, — -- --------- _-- ORIGINAL APARTMENT (e} e `- COUNTERTOP <br /> AND LOCATIONS OF Q \ T. <br /> CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY TRANSFORMER/SWITCHBOARD A5 NOTED -- 1 NEW HOUSE/CAFE PANEL=23693 W (e)POS Al ( GFI GRINDER W I„• 0 �` a <br /> THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT I I TOTAL= 105,41 8 W =439A ON 800A GFI OUTLET \ <br /> 10 <br /> AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES. I <br /> (e)800A- 12D1240V BUS l <br /> UC REF 1, U) V u <br /> COMMUNICATIONS I I p Y <br /> 6. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN UNLESS OTHERWISE TELEPHONE BACKBOARD, PROVIDE#8 GND TO SERVICE GROUND NEW ESPRESSO MAKER <br /> M _ 1 REUSE DEDICATED �_ Z <br /> GFI o <br /> NOTED OR REQUIRED BY CODE. \ - <br /> } I (e} CIRCUIT HP-30 FOR 30A/240V OUTLET 0 N E a <br /> 7, THE OWNER RESERVES THE RIGHT TO <br /> RELOCATE ALL LIGHTING, OUTLETS AND COMMUNICATIONS OUTLET, PHONE & DATA I (e)100 l _,,/OPEN DELI CASE (e) U N <br /> SWITCHES BEFORE THEY ARE ROUGHED IN AT NO EXTRA COST. \ PHONE ONLY OUTLET, PREWIRED WITH CAT 5e CABLE I I REPLACE WITH \� <br /> 2 I 150A/2 METER H <br /> & OUTLET P-29131 <br /> WIRING METHODS: DATA ONLY OUTLET JACK, PREWIRED WITH CAT 6 CABLE <br /> �— -------- ,-- USE EXISTING COUNTER <br /> —.---------� #10 (e) OUTLET FOR COFFEE 7F, <br /> 1. ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS, CONCEALED IN WALL AND --- (e)GROUND (e) <br /> BLENDER <br /> CEILING U.O.N. MOUNTING HEIGHTS FINISHED CEILING (e) GFf_ <br /> ALARM APPLIANCE (e)1.5"C REPLACE FEEDER <br /> AUDIBLE FIRE e <br /> = GFI <br /> 2. MINIMUM CONDUIT SIZE SHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS ARE Gp WITH 3#110+1#6 GND. m W ( ) <br /> A. GALVANIZED RIGID STEEL.. NOT LESS THEN 90"AFF OR AT <br /> LEAST 6" BELOW CEILING <br /> B. GALVANIZED STEEL EMT. ❑� <br /> __..,. _.. ..... <br /> C. LIQUID TIGHT STEEL FLEX- FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. 1\ <br /> '�- USE EXIST DEDICATED �+ - REUSE EXISTING Cl <br /> li RCUlT <br /> D. FLEXIBLE STEEL CONDUIT- FOR INDOOR FINAL CONNECTIONS TO VISUAL APPLIANCE TO BE PANEL REPLACE WITH 150ACIRCUIT HP-42 FOR HP-22 FOR NEW ICE MACHINE z <br /> MECHANICAL EQUIPMENT(NOT TO EXCEED 36"). NOT LESS THAN 80"AFF MIN, HP PANEL UG. REF COFFEE BREWER <br /> J <br /> E. PVC CONDUIT SCHEDULE 40, UNDERGROUND. AND NOT MORE THAN 96"AFF <br /> � -- <br /> 3. NMC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING. 12"TYPICAL TO BOTTOM NOTE: ALL 120V OUTLETS IN THE 120/240V, 3W <br /> 4. MC CABLING SYSTEMS IS ALLOWED IN THIS BUILDING. <br /> ` - FIRE ALARM MANUAL FOOD PREP AREA ARE TO BE GFl <br /> 51 naw <br /> WIRING DEVICES: I PULL STATION SHALL NOT <br /> SYSTEMS FURNITURE ` I REQUIRE "TIGHT GRASPING, J <br /> UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS CONNECTIONS +15"TO I PINCHING OR TWISTING OF ARC FLASH LABELLING REQUIREMENT: <br /> THE FOLLOWING LABEL ASA MINIMUM <br /> BOTTOM OF BOXES - \ THE WRIST" PROVIDE <br /> (BROWN, WHITE, GREY, BEIGE OR IVORY)AS SELECTED BY THE ARCHITECT: \ 4r <br /> FOR COMPLIANCE WITH NFPA AND NEC ON 1 CONVIENCS OUTLETS, THIS PROJECT: ELECTRICAL PLAN <br /> A. WIRING DEVICES LEV[TON# HUBBELL# P &S# PHON <br /> SINGLE POLE SWITCH 1221 1221 20AC1 PHONE & DATA OUTLETS, \ ® � THERMOSTAT SCALE: 114" 1'-D" <br /> 1223 1223 20AC3 +15"TO BOTTOM \ OR WALL PHONE Q DANGER <br /> THREE WAY SWITCH OF BOX \ <br /> DUPLEX CONY. OUT. 15A 5262 5262 5262 LIGHT SWITCHES ARC FLASH AND SHOCK HAZARD <br /> DUPLEX GFI CONY. OUT. GF5262 \v `� FOLLOW ALL REQUIREMENTS IN NFPA 70E iU <br /> �� 48"TO TOP FOR SAFE WORK PRACTICES AND FOR <br /> OF BOX PERSONAL PROTECTIVE EQUIPMENT ' f <br /> DEVICE PLATES: FINISHED FLOOR W <br /> w J <br /> J <br /> 1. ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED EQUAL r— Uj <br /> UNLESS OTHERWISE NOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL BE RAISED 2 ~ <br /> METAL. Z ONE LINE DIAGRAM <br /> SCALE: NTS <br /> 2. DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2" RAISED STEEL PLATES. <br /> WEATHERPROOF COVERS TO BE SNAP TYPE COVERS. <br /> 3. DEVICE PLATES FOR TELEPHONE AND COMPUTER OUTLETS TO BE PROVIDED BY <br /> OWNER'S VENDOR. ALL TELEPHONE AND COMPUTER SYSTEM WIRING BY OWNER'S <br /> VENDOR. (e)PANEL HP <br /> Location: Volts: 1201240 Single A.I.C. Rating: EXIST <br /> SUPPORTS: <br /> Mains Type: <br /> Supply From: Phases: 1 <br /> i. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL Mounting: Recessed Wires: 3 Mains Rating: 100 A <br /> ELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT. Enclosure: NEMA 1 MCB Rating: 100 A <br /> 2. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO <br /> METAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS Notes: <br /> AND MACHINE SCREWS OR BOLTS. REPLACE PANEL AND UPGRADE WITH NEW 150 AMP PANEL <br /> GROUNDING: <br /> 0 t <br /> 1 <br /> GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND <br /> 1 1 <br /> SPECIFICALLY INCLUDING SWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC. CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT W <br /> HP-1 (e)PARKING LOT LIGHTS 20 A 1 500 VA 360 VA 1 2D A (e)ROOF OUTLET HP-2 � <br /> PANELBOARDS: — Lu U <br /> HP-3 (e)CEF 20 A 1 252 VA 180 VA 1 20 A (e IRRIGATION HP-4Lu <br /> HP-5 (e)STAIR LIGHTS 24 A 1 377SVA 104 VA 1 20 A (e)FACP HP-6 0 U <br /> UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON Tcc <br /> HE PANEL SCHEDULE, 20 A 1 540 UA, 360'VA 1 20 A (e)CASH REGISTER OUTLET HP-8 O Q °C <br /> HP-7 (e)OUTLETS <br /> WITH THE NUMBER AND SIZE OF BREAKERS INDICATED ON THE PANEL SCHEDULE. SINGLE 20 A 1 600.VA 360 VA 1 20 A (e PHONE _ HP-10 a <br /> SHALL BE BOLT-ON TYPE. THE PANEL HP-9 NEW UC REF <br /> POLE, TWO POLE AND THREE POLE BREAKERSHP-11 MICROWAVE 20 A 1 1000 VA' 6(];VA 1 20 A (e)CATV HP-12 ~ 0 x <br /> DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKE AND HAVE 20 A 1 24D VA 600 VA 1 20 A e COFFEE HP-14 U <br /> W z O � o � <br /> HP-13 (e)CIRC PUMP w <br /> TYPEWRITTEN DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICED BY ( ) HP-16 <br /> G SHALL BE COPPER. HP-15 Kitchen Equipment- Non-Dwelling Unit 20 A 1 600 VA OL <br /> LU o O <br /> EACH BREAKER, ALL BUSSING HP-17 (e)WATER HEATER 20 A 1 8¢IIA _ HP-18 <br /> HP-19O.VA 1 20 A SPARE HP-20 <br /> WORKING CLEARANCES FOR PANE=LS &SWITCHBOARDS HP-21 (e)CIRCUIT PUMP 20 A 1 240 VA =120Q VA 1 20 A ICE MACHINE HP-22 <br /> 1. COORDINATE WITH OTHER TRADES TO ENSURE CODE REQUIRED WORKING HP-23 (e)FIRE BELL 20 A 1 100 VA 300 VA i 20 A (e)LIGHTS HP-24 <br /> CLEARANCES, ACCESS, ETC. FOR PANELS AND SWITCHBOARDS PER C.E.C. SECTIONS HP-25 ESPRESSO 30 A 2 2400 VA 1080 VA 1 20 A (e)OUTLETS HP-26 <br /> 110-16 AND 384-4. HP-27 - -- -- 2400 VA 540 VA 1 20 A (e)OUTLETS <br /> HP-28 <br /> HP-29 BREWER 30 A 2 2550 VA 600 UA 1 20 A DELI CASE <br /> _ HP-3D STAMP <br /> TESTING: <br /> HP-31 -- -- -- 25501fA' S4Q VA .' 1 20 A (e)OUTLETS HP-32 <br /> HP 33 100 VA 1 20 A (e}RESTROOM HP-34 <br /> INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND HP-35 1204 VA 1 20 A (e.)FAN COIL HP-36 eR�F sloN <br /> 1. THE ENTIRE ELECTRICAL �� R4 c <br /> S. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND HP-37 1867 VA 2 30 A (e)CU HP-38 M��Fyc <br /> IMPROPER GROUND __ <br /> GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHETHER SUCH HP_39 1867 VA - HP-4D y z <br /> E FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED, HP-41 6Q4 VA 1 20 A NEW UC REF HP-42 ` <br /> TESTS INDICAT777 <br /> E � Exp.' 5�30�19 <br /> REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. Total Load: 13854 VA 12789 VA * P <br /> I + <br /> Total Amps: 115A 107 A - <br /> OWNER AND THE ARCHITECT, THAT THE ENTIRE INSTALLATION II 'l4 �gr�ECTR tiCP���Q <br /> 2. DEMONSTRATE TO THE end: <br /> COMPLETE, IN PROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN Legend: f op- <br /> is CAI�Fo <br /> PROPERLY AND FULLY EXECUTED. PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS. <br /> y r <br /> Load Classification Connected Load Demand Factor Estimated Demand Panel TotalsM) <br /> Kitchen Equipment- Non-Dwekling Unit 7500 VA 70,00% 5254 VA � A <br /> DRAWN <br /> RCS <br /> Receptacle 7000 VA 90.00% 6300 VA Total Conn. Load: 26643 VA <br /> Spare 12143 VA 100.00% 12143 VA Total Est. Demand: 23693 VA CHECKED <br /> Total Conn.: 111 A RCS <br /> Total Est. Demand: 99 A DATE <br /> �_ 8/10/2018 1 1:54:45 AM <br /> SCALE <br /> _ - As indicated <br /> Notes: <br /> JOB <br /> "SPARE" ARE EXISTING LOADS <br /> 2D17.xxx <br /> SHEET <br /> C:\Users\RichardSmith\HCS ENGINEERINGIProjects-Documents\Add to 20181LeeJagoe UOP Cate1UOP CAFE ELECTRICAL.rvt <br />