Laserfiche WebLink
TI.1 COVER SHEET <br /> TI.2 GENERAL NOTES <br /> TI.3 ACCESSIBILITY NOTES <br /> T1.4 GAL GREEN MANDATORY MEASURES SHEET I <br /> TIS GAL GREEN MANDATORY MEASURES SHEET 2 <br /> Tf.b GAL GREEN MANDATORY MEASURES SHEET 3 <br /> T13 EGRE55 PLAN <br /> A5.1 51TE PLAN <br /> AI.I FLOOR PLAN <br /> A1.2 G02 SENSOR PLAN <br /> A2.1 REFLECTED CEILING PLAN <br /> A2.2 REFLECTED GELLING DETAILS - <br /> A3.1 ENLARGED TOILET PLAN AND INTERIOR ELEVATIONSPROTO 04=30=18 <br /> - <br /> A3.2 TOILETS INTERIOR ELEVATIONS <br /> A4.1 MATERIALS 5GHEOULE5 <br /> 121 S CENTER STREET A4.2 DOOR SCHEDULES <br /> WL <br /> STOCKTON , CA <br /> � � ,44.3 WALL AND FLOOR FINISH PLAN <br /> A4.4 INTERIOR ELEVATIONS - a--+ � x <br /> v „� <br /> I. GON5ULT NTH ARGHITEGT BEFORE DOING WORK RELATED TO THAT BEING ADDRESS: 121 5 CENTER STREET A4.5 EQUIPMENT AND INTERIOR ELEVATIONS I" �! <br /> 0 <br /> INSPEGTED. <br /> IES THE MATERIALS, <br /> E SHALL BE SOLELY RESPONSIBLE FOR ALL GAL GREEN REFERENCE NOTES: I. EXTERIOR 51ONAOE STOCKTON, GA x5202 Ab.I GANOPY EXTERIOR ELEVATIONS - o <br /> QUANTITIES OF MATERIALS, EQUIPMI=NT, OR SUBSYSTEMS REQUIRED TO COMPLETE l,' � � <br /> WORK. 2. FUELING SYSTEM OWNER: 7-ELEVEN, ING A7.1 ROOF PLAN L <br /> i. GENERAL CONTRACTOR SHALL READ AND REVIEW SHEETS T1.2-TI.4. 3200 HAGKBERRY ROAD A8.1 AGGE55IBILITY COMPLIANCE DETAILS �; . , o � <br /> 2. BEFORE BEGINNING WORK AT THE SITE, INSPECT THE EXl5TING BUILDING AND 2. GENERAL CONTRACTOR SHALL PROVIDE TO THE CITY OF ATWATER A 3. PRICE 5 0NAGE IRVING, TEXAS 75063 < �� 0 <br /> A8.2 DETAILS DETERMINE 7HE EXTENT OF EXISTING FINISHES, SPECIAL TIES, GA5EWORK, CONSTRUCTION WASTE MANAGEMENT PLAN. o <br /> EQUIPMENT AND OTHER ITEMS WHICH MUST BE REMOVED AND REINSTALLED IN I A8,3 DIGITAL MENU BOARDS INSTALLATION GUIDE AND DETAILS �,' �+ � � � �- <br /> ORDER TO PERFORM THE WORK UNDER THIS GONTRAGT. NEITHER THE OWNER NOR 4. PARKING LOT LIGHTING ASSESSOR'S PARCEL NUMBER: 13 -300-OILPL <br /> 3. GENERAL CONTRACTOR ET PROVIDE BUILDING OWNER, AT THE END OF A8.4 DIGITAL MENU BOARDS INSTALLATION GUIDE AND DETAILS I` o 3 <br /> THE ARCHITECT WILL BE RESPONSIBLE FOR OVERSIGHT OR OM15510N5 IN BID GONSTRUGTION A COMPLETE BUILDING OPERATION AND MAINTENANCE MANUAL SITE AREA. -0 <br /> PREPARATION AND FULL DOCUMENTATION. 30,936 5Q. FT. OR 0.71 AGRE51 �f> <br /> O <br /> 3. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS WHERE WORK MUST BE 4. MECHANICAL CONTRACTOR SHALL COMPLY WITH SECTION 5.504.3 DUCT ZONED: GD (COMMERCIAL DOWNTOWN) MOD MECHANICAL - LEGEND, NOTES � SCHEDULES - � � N <br /> AGGOMPL15HED UNDER THIS GONTRAGT. INCIDENTAL WORK MAY ALSO BE PROTECTION. MO.I MEGHANIGAL - GREEN BUILDING CODE NOTES <br /> TYPE OF CONSTRUCTION: V-B <br /> NECESSARY IN AREAS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS DUE TO M0.2 MECHANICAL - SPI=GIFIGATIONS <br /> CHANGES AFFECTING THE EXI5TING MEGHANIGAL, ELECTRICAL, PLUMBING OR 5. GENERAL CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR GOMPLIANGE <br /> OTHER SYSTEMS. SUCH INCIDENTAL WORK IS AL50 PART OF THIS CONTRACT, OCCUPANCY GROUP: M ,1 <br /> WITH SECTIONS 5.504.4 AND 5540.4.6. M0.3 REFRIGERATION - SPECIFICATIONS <br /> INSPECT THOSE AREAS AND ASCERTAIN WORK NEEDED AND DO THAT WORK IN <br /> ACCORDANCE WITH THE CONTRACT REQUIREMENTS AT NO ADDITIONAL COST. <br /> TOTAL BUILDING AREA: 2,x40 50. FT. MI.O MECHANICAL - FLOOR PLAN <br /> M2.0 MECHANICAL - ROOF PLAN ��� Agcy <br /> 4. TRADE, PRODUCT OR MANUFACTURER'S NAME OR CATALOG NUMBERS SHOWN ON OCCUPANT LOAD: 30 OCCUPANTS M3.0 MEGHANIGAL - DETAILS �� �e �T <br /> THE DRAWINGS FOR NEW PRODUCTS ARE TO ESTABLISH QUALITY REQUIRED. IN c� <br /> EACH CASE ADD BY INFERENCE AFTER TRADE, PRODUCT OR MANUFAGTURER'S '"f CAL GREEN (E) BUILDING HEIGHT: 25'-3" M3.1 MECHANICAL - DETAILS p C 8827 v� <br /> NAME THE PHRASE "OR APPROVED EQUAL 12 SEPARATE SUBMITTALS M3.2 MECHANICAL - DETAILS <br /> EXITS PROVIDED: 2 <br /> 5. TRADE PRODUCT OR MANUFACTURER'S NAME OR CATALOG NUMBERS AND EM51-O ENERGY MANAGEMENT SYSTEM `' � <br /> I. PROVIDE SEPARATE ITEMIZED L15T FOR ALL WORK (LABOR FIRE SPRINKLERS: NO R;30'19L �� <br /> INDICATION OF PRODUCT TYPES, SUCH A5 "GLASS FIBER INSULATION% SHOWN ON MATERIALS OVERHEAD) ASSOCIATED WITH THE FOLLOWING F <br /> T24.1 ENERGY COMPLIANCE of c p,\,` <br /> T DRAWINGS FOR EXISTING PRODUCTS ARE BELIEVED TO BE ACCURATE. IF THEY I. INSTALLATION OF THE SUSPENDED CEILING I"I;! <br /> ITEMS: JURISDICTION: CITY OF STOGKTON T24.2 ENERGY COMPLIANCE <br /> ARE P15GOVERED TO BE INACCURATE, NOTIFY ARCHITECT IMMEDIATELY AND DO L <br /> NOT PROCEED WITHOUT INSTRUCTIONS. A. FLOOR FINISHES. <br /> 6. PARKING REQUIRED: 12 STALLS (2,0140 SQ, FT./ (I PER 250 SQ. FT.) POD PLUMBING - LEGEND, NOTES 4 5GHEDULE5 <br /> PROTECT EXISTING WORK TO REMAIN FROM DAMAGE. B. PO.1 PLUMBING - GREEN BUILDING CODE NOTES 4 SPECIFICATIONS t <br /> GONC, 5 GUTTING � PATCHING PARKING PROVIDED: 17 STALLS (10 STANDARD, b GAS FUEL STALLS, <br /> PI.O PLUMBING - FLOOR PLAN WASTE AND VENT <br /> PAIR, PATCH AND FINISH OR REFINISH AS APPLICABLE TO MATCH ADJACENT AND I ACCESSIBLE) PI I P - <br /> EXISTING FINISHES, TH05E EXISTING SURFACES DAMAGED, OR NEWLY EXPOSED G. CEILINGS. PLUMBING FLOOR PLAN WATER AND GAS p. <br /> DURING PERFORMANCE OF THE WORK UNDER THIS CONTRACT. D. LIGHTING. <br /> uj <br /> P2.0 PLUMBING - ROOF PLAN <br /> 8. WHERE PERMANENT REMOVAL OF EXISTING MILLWORK, CASEWORK, CABINETWORK, THIS PROJECT TO COMPLY WITH THE FOLLOWING CODES: 1'3.0 PLUMBING - DETAILS <br /> AGGE550RIE5, EQUIPMENT OR FURNISHINGS 15 REQUIRED AND PREVIOUSLY E. HVAC. T` <br /> P3.1 PLUMBING - DETAILS <br /> CONGEALED SURFACES ARE TO REMAIN EXPOSED, PATCH PREVIOUSLY EXPOSED 2016 CALIFORNIA BUILDING GORE, VOLUMES 1-2 <br /> SURFACE, WHERE SUCH 5URFAGE5 ARE SCHEDULED TO RECEIVE NEW FINISHES, <br /> EO.I ELECTRICAL SITE POWER PLAN <br /> P PARE THE SURFACES TO RECEIVE NEW FINISHES. 1 BID NOTES " SPECIAL INSPECTIONS 20I6 CALIFORNIA ELECTRIC CODE �ry <br /> EI.O ELEGTRIGAL FLOOR PLAN z s <br /> 151. WHERE GUTTING OF EXISTING SURFACES OR REMOVAL OF EXISTING FINISHES 15 20Ib CALIFORNIA MEGHANIGAL CODE <br /> REQUIRED TO PERFORM THE WORK UNDER TH15 CONTRACT, AND A NEW FINISH IS ELI PANEL SCHEDULES AND ONE-LINE DIAGRAM � LU <br /> PROJECT LOCATION J <br /> NOT INDICATED, FILL RESULTING OPENINGS AND PATCH THE SURFACE AFTER DOING 20Ib GALIFORNIA PLUMBING GODS E1.2 ELECTRICAL SLAB PENETRATION PLAN '�'`_ <br /> THE WORK AND FINISH TO MATCH EXI5TING ADJACENT SURFACES. DETAIL NUMBER <br /> 2016 CALIFORNIA FIRE GODS E1.3 ELEGTRIAL HYAG-R PLAN <br /> �iRECTION OF VIEW/EXTENT ` s' <br /> 10. WORK SHOWN IS NEW UNLESS SPECIFICALLY NOTED OR OTHERWISE INDICATED A54 '' F E1.4 LOW VOLTAGE FLOOR ` <br /> t° PLAN <br /> EXISTING. DETNL �� A8.1 wl 2016 CALIFORNIA ENERGY CODELU co <br /> xii <br /> 11. WH > C*3 <br /> ERE "(E)" PRECEDES A REFERENCE TO A MATERIAL OR PRODUCT, THE " 'I <br /> E1.5 LOW VOLTAGE DETAILS <br /> 2DIb GALIFORNIA GREEN BUILDING STANDARDS CODE <br /> SHEET NUMBER WHERE El.b ELECTRICAL DETAILS <br /> MEANS THAT THE INDICATED MATERIAL OR PIR 15 EXISTING. DETAIL Is DRAWN. 17 <br /> � � 2.0 LIGHTING PLAN <br /> TITLE 24 G.G.R.G.G.R, ACCESSIBILITY STANDARDS AMERICANS WITH DISABILITIES, <br /> est I �� DISABLED AGGE55 COMPLIANCE PER GBG CHAPTER fl-B <br /> 12. PROVIDE A KNOX COMPANY KEY SOX APPROVED BY THE FIRE DEPARTMENT .. �t;e�a � ��, „ �L ,� . ' , , <br /> HAVING JURISDICTION PER 20I6 GFG. CONTACT THE FIRE DEPARTMENT HAVING <br /> E2.1 INTERIOR PHDTOMETRIGS 'T W <br /> -JURISDICTION FOR REQUIREMENTS. <br /> DIRECTION OF VIEW <br /> LOCATION ON SHEEP k= <: st,». <br /> E2.2 EGRESS PHOTOMETRIGS <br /> L <br /> 13. THE GONTRAGTOR 15 RESPONSIBLE FOR PROVIDING LABOR, MATERIALS, AND SECTION 'CtJi' TD <br /> E3,0 ELECTRICAL SPECIFICATIONS <br /> 5 PROJECT INFORMATION A6., -- „ ,..,.., NAND CODE " O <br /> EQUIPMENT NEGE55ARY FOR THE PROPER EXEGUTION AND COMPLETION OF THE `�-SHEET NUMBER WHERE S <br /> WORK. SECTION IS DRAWN. PLAN <br /> EF-I EQUIPMENT <br /> I4. REVIEW AND APPROVE ALL ELECTRICAL POWER SITES AND INSTALL PHONE, GOMM, <br /> X. t t EF-I.I EQUIPMENT SCHEDULE <br /> + n z ca <br /> EF-2 FIXTURE PLAN <br /> AUDIOVISUAL AND SECURITY SYSTEMS PRIOR TO INSTALLATION OF DRYWALL. *>„< TENANT IMPROVEMENT OF CONVENIENCE STORE WITH FUELING CANOPY L <br /> SERVING UNLEADED GAS AND DIESEL FUEL <br /> OFFICE--__ u � W <br /> 15. CONTRACTOR TO COORDINATE WITH VENDORS (SUCH A5, BUT NOT LIMITED T0: NAME OF ROOM w G51 FUEL CANOPY STRUCTURAL NOTES AND PLANS <br /> IL <br /> SECURITY, PHONES, DATA, AUDIOVISUAL, ETC.) AND ALLOW AGGE55 TO THE ROOM TAC �p� Roots NUMBER `+> EXTERIOR SIGNAGE. (SHALL BE SUBMITTED SEPARATELY FOR PERMIT BY 515N <br /> 6 L VENDOR) G52 FUEL CANOPY MANSARD PLAN AND DETAILS L U; Z w o <br /> GONSTRUGTI ON Si TE A5 NECESSARY. CONTRACTOR TO ADVISE WHEN READY, W w c� <br /> ' �' C53 FUEL CANOPY STRUCTURAL DETAILS T �} <br /> NORTH SEE DRAWINGS FOR FULL SCOPE OF WORK FOR ENTIRE PROJECT. THIS W Uj <br /> Ib. THE CONTRACTOR SHALL GHEGK ALL DIMENSIONS AT THE JOB AND SHALL BE s ' <br /> RESPONSIBLE FOR ALL DI5GREPANCIE5 BETWEEN DIMEN510N5 OF THE ACTUAL ff <br /> SUMMARY DOES NDT CHANGE OR SUPERSEDE WHAT IS SHOWN IN DRAWINGS. O W N Q <br /> WORK AND TH05E SHOWN IN THE DOCUMENTS OR ARCHITECT'S APPROVED xxxx <br /> �:�:::: a w <br /> DRAWINGS WINDOW TACCC <br /> WINDOW TYPE y <br /> A REFER TO WINDOW SCHEDULE r, ``k <br /> 17. IT }S THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ASSUME ALL THE :5 <br /> LU <br /> Z O <br /> UJ <br /> Z V Y <br /> .F <br /> SYSTEMS AND SUBLL <br /> -SYSTEMS DESCRIBED IN THESE DRAWIN65 COMPLY WITH NORtN <br /> Z p <br /> APPLICABLE CODES AND ARE A COMPLETE AND FINISHED PRODUCT. ALL ��.,� W r <br /> INQUIRIES AS TO THE NATURE OF THESE SYSTEMS OR APPARENT CONFLICTS NDICATES REFERENCE NORTH N <br /> AMBIGUITIES AND OMISSIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE <br /> 'I Q VICINITY MAP 4 SCOPE OF WORK <br /> ARCHITECT PRIOR TO OBTAINING BIDS FOR CONSTRUCTION G05T ESTIMATES. <br /> NOM ARROW <br /> !8. THESE PLANS ARE FOR GENERAL GON5TRUGTION PURPOSES ONLY. THEY ARE NOT ARCHITECT <br /> REV f 510N5: <br /> X AUSTIVELY DETAILED NOR FULLY SPECIFIED, IT 15 THE RESPONSIBILITY OF <br /> L STREET ARCHITECTS, LIMITED <br /> T CONTRACTOR TO SELECT, VERIFY, RESOLVE AND INSTALL ALL MATERIALS ,I J <br /> AND EQUIPMENT. INDICATES ELEVATION HEIGHT 1414 L STREET <br /> SAN.JOAQUIN COUNTY <br /> ELEVATION DATUM___�`� �=INDfCATES LINE OF HEIGHT MODESTO, GA X5354 �NVIF�ONMENTAt.HEALTH DEPARTMENT - <br /> H. THE ARGRTEGT WILL NOT BE OBSERVING THE CONSTRUCTION OF THIS PROJECT. OFFICE: (209) 5-15-1415 <br /> FAX: (209) 575-4374 1`$68 E. HAZELTON AVE. s <br /> THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE QUALITY CONTROL AND �TQCKTON; CA 95205 `_' <br /> CONSTRUCTION STANDARDS FOR THIS PROJECT, ALL QUESTIONS AND a D ^] <br /> 209):468'3,420 t` <br /> IL <br /> CLARIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. INDICATES Roots WITCH DOOR Is LOCATED MEGHANIGAL/PLUMBING ENGINEER f�A$rpro.+reii , <br /> DOOR TAC 0�,� INDICATES b06R NUMBER NEXUS ENGINEERING �7approired with chang6s. Soe Remarks' <br /> 20. IT IS THE RESPONSIBILITY OF THE OWNER TO IDENTIFY, PROVIDE TESTING FOR AND -REFER TO DOOR SCHEDULE �J Disapproved;See Remarks ,- <br /> 1400 LONE PALM AVENUE, SUITE A DRAWN: C, MEJIA <br /> REMOVEANY HAZARDOUS MATERIAL. F2emartFs <br /> MODESTO, GA 95351 <br /> OFFICE: (209) 572--1399 F <br /> 21. RELOCATE EXISTING THERMOSTAT(5) AS REQUIRED. �DlRECTION OF VIEW FAX: (209) 572-7399 <br /> c DATE: 07/10/2018 <br /> NUMBER OF VIEW � , <br /> 1 Ilk <br /> 22. PRIOR TO OCCUPANCY CONTRACTOR SHALL PROVIDE AND INSTALL 2-�A.10-B:G 6a� ELLE: <br /> FIRE EXTINGUISHERS SUCH THAT NO POINT IN BUILDING 15 FURTHER THAN 75-FOOT INTERIOR ELEVATION TAC 4 A5.T 2� <br /> TRIG Approval extende Only to tf7at which is'shown� d described 42-7-T]f <br /> TRAVEL P157ANGE TO AN EXTINGUISHER. EXTINGUISHERS HAVING A 6RO55 WEIGHT ELEVATION NOS Itiereoh and does not sathorize or is she any omission or <br /> SHEET NUMBER WHERE SECTION IS DRAWN. MILLER PEZZONI $ ASSOCIATES, INC. deviation from requirements of state:laws or local ordinances. `-II JOB: 70.427 <br /> NOT EXCEEDING 40 POUNDS SHALL BE INSTALLED 50 THAT THE TDP OF THE FIRE �iO�f FIFTEENTH STREET, STE 7 z <br /> EXTINGUISHER IS NOT MORE THAN 5 FEET ABOVE THE FLOOR. FIRE EXTINGUISHERS MODESTO, GA x5354 <br /> HAVING GROSS WEIGHT GREATER THAN 40 POUNDS (EXCEPT WHEELED TYPES) DFFIGE: (209) 575-0312Le <br /> SHALL BE 50 INSTALLED THAT THE TOP OF THE FIRE EXTINGUISHER 15 NOT MORE FAX: (209) 575-0813 c!i <br /> THAN 3 1/2 FEET ABOVE THE FLOOR. IN NO CASE SHALL THE CLEARANCE BETWEEN I�I�D TAG DESIGNATES LEGENED NOS = "" <br /> THE BOTTOM OF THE EXTINGUISHER AND THE FLOOR BE LE55 THAN 4 INCHES. -SEE LEGEND DISCRIPTION n <br /> 4 r <br /> TITLE SHEET <br /> GONSTR�JGTION PROG7 MANAGER GONTAGT RU55 OR51, R.OR51@5MITfHDGG.GOM, `> PROJ <br /> SMITH DEVELOPMENT # CONSTRUCTION FOR ALL RFI'5, GUE5TION5 REGARDING ECT INFO <br /> 7803 MADISON AVE. #100G BIDDING, OR FOR A L157 OF O- NERAL , SHEET INDEX <br /> 7 ELEVEISI 4c () rsi VENIE11+4 ICE FIUEL <br /> STORE # 38153 <br /> G I TRUS HE I 6HT5, GA 95b 10 GONTRAGTORS <br /> OFFICE: (916) 966-1325 CONSULTANTS <br /> VICINITY MAP <br /> 17 GENERAL NOTES 13 SYMBOLS 9 CONSULTANTS <br /> 1 SHEET INDEX ' <br /> III: T1 . 1 <br /> rL-: <br />