Laserfiche WebLink
:Mop <br /> GENERAL NOTES SIGNAGE GENERAL NOTES �, �. <br /> SN1 MEN'S RESTROOM (REFERENCE A6.0) 1. ALL INTERIOR FINISHES TO BE CLASS 2 OR BETTER. <br /> 1. OSB IS NOT AN APPROVED CONSTRUCTION MATERIAL AND SHALL NOT BE SUBSTITUTED FOR 5N2 WOMEN'S RESTROOM (REFERENCE A6.Q) <br /> FIRE TREATED PLYWOOD. 2. CONTRACTOR TO FLOAT AND SCRAPE FLOOR TO BE LEVEL AND PREPARE FOR NEW <br /> SN3 EMPLOYEES ONLY, <br /> 2. ALWAYS WATERPROOF DEMISING WALLS IN WET AREAS, INCLUDING BEHIND COOLER/ FREEZER SN4 THIS DOOR IS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. (INOTE: THE SIGN SCHEDULED FINISH, AS REQUIRED. <br /> AND BEVERAGE COUNTER. SHALL BE IN LETTERS 1 INCH HIGH ON A CONTRASTING BACKGROUND.) 3. CONTRACTOR TO RESERVE SPECIFIED FLOORING AND BASE UPON BEING AWARDED THE <br /> SN5 EXIT TACTILE SIGN'PER LOCAL BUILDING CODE BID TO ENSURE AVAILABILITY AND TIMELY INSTALLATION. SUBSTITUTIONS ARE NOT - <br /> 3. ALL SUBSTRATES ARE TO EXTEND TO DECK, UNLESS NOTED OTHERWISE. PERMITTED. <br /> 4. ALL WALL FINISHES IN THE MERCHANDISE/SALES AREAS SHALL BE FRP WALL PANEL"FRP-A" <br /> KEY NOTES 4. FLOORS IN WET AREAS TO SLOPE TO DRAINS 1/8" PER FOOT, TYP. n <br /> UNLESS NOTED OTHERWISE ON THE FLOOR PLAN. (REFERENCE SHEET A3.0 FOR MATERIALS 5. PROVIDE A BEAD OF CAULK AT INTERIOR CONDITIONS PER OWNER DIRECTION AND <br /> SCHEDULE). CONCRETE SLAB TO BE GROOND, SEALED, AND POLISHED WHERE INDICATED ON FINISH PLAN PROJECT NEEDS. CAULK IS TO MATCH COLOR OF ADJACENT MATERIAL. <br /> - REF: A6.1 FOR MATERIALS SCHEDULE. CONTROL JOINTS TO BE PROVIDED IN CONCRETE PER o <br /> 5. PROVIDE FULL HEIGHT CORDER GUARDS AND "T" MOLDING AS REQUIRED AT ALL OUTSIDE PLAN - REF: STRUCTURAL. 6. REFERENCE INTERIOR ELEVATIONS FOR WALL FINISHES. <br /> CORNERS AND PANEL JOINTS. CORNER GUARDS SHOULD BE FOR MATERIAL FINISH SPECIFIED 7. REFERENCE SHEET A6.1 FOR BASE TYPES. <br /> 5/8" HARDIBOARD 5/8" HARDIBOARD 3/4" FIRE TREATED IN FINISH AND MATERIAL SCHEDULES ON SHEET A6.0. F2.] IF TILE IS USED-TILE TO BE INSTALLED UP TO EDGE OF MOP SINK. s <br /> 8. FIRE EXTINGUISHER: 910 CLASS ABC WITH UL HATING 4A-603C. SURFACE MOUNTED ON <br /> ATTACHED W/ I" TYPE 'S' ATTACHED W/ I" TYPE 'S' PLYWOOD ATTACHED 1fl THRESHOLD TO BE SET IN FULL BED OF MASTIC. WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. (COSMIC 10E) <br /> 6. ALL INTERIOR FACE OF EXTERIOR SIP PANEL WALLS TO BE COVERED WITH 1/2" GYPSUM <br /> SCREWS 8" O.G. ALONG SCREWS ® 8" O.G. ALONG W/ I" TYPE 'S' SCREWS OR APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL CODES. <br /> EDGES, 12" O.G. IN THE EDGES, 12" O.G. IN THE C 16" O.G. ALONG BOARD FROM FLOOR TO ROOF DECK TO MEET FLAME SPREAD RATING. ATTACHED W/ 1" TYPE <br /> FIELD OF THE BOARD. FIELD OF THE BOARD. EDGES IN THE FIELD C @ 4❑ FLOOR SINK/DRAIN PER PLAN, REF. DETAILS ON THIS SHEET& PLUMBING DRAWINGS FOR <br /> S' SCREWS 8"O.C. ALONG EDGES, 12" O.C. IN THE FIELD OF THE BOARD. JOINTS ORIENTED 9. CONTRACTOR TO INSTALL 7-ELEVEN PROVIDED COAT HOOKS FOR EMPLOYEES. REFERENCE <br /> LOCATION. <br /> VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF ASSEMBLY TO BOTTOM OF ROOF DECK. SHEET EF1ITEM 220. INSTALL 2 IN OFFICE AND 3 IN BACKROOM. LOCATION TO BE « <br /> JOINTS ORIENTED JOINTS ORIENTED OF THE BOARD. v _ <br /> VERTICALLY AND VERTICALLY AND JOINTED ORIENTED ** IF TILE IS USED- CONTRACTOR TO CUT TILE STRAIGHT AND TRUE, NOT LESS THAN 1/2 A TILE. DETERMINED BY CONSTRUCTION PROJECT MANAGER. SEE DOOR HARDWARE SCHEDULES. <br /> STAOGERED ON OPPOSITE STAGGERED ON OPPOSITE VERTICALLY AND 7• ALL SUBSTRATES ARE TO BE APPLIED OVER AND IN ADDITION TO THE WALLBOARD REQUIRED 10. APPLY 3M SUN CONTROL WINDOW FILMS @ALL SOUTH EAST AND WEST FACING GLASS <br /> SIDES OF ASSEMBLY TO SIDES OF ASSEMBLY TO STAGGERED ON FOR FIRE RATED WALL CONSTRUCTION DESCRIBED ON THIS SHEET.** L <br /> TEXTURED PORTION OF RAMP INDICATES DETECTABLE WARNING:ARMOR TILE TACTILE (3M-1). NOTE NO FILM SHOULD BE APPLIED TO THE STOREFRONT DOORS. (REFERENCE <br /> BOTTOM OF ROOF DECK. BOTTOM OF ROOF DEGK. OPPOSITE 51DE5 OF SURFACE, BRICK RED. SIZE AND PATTERN SUBJECT TO LOCAL AND STATE REQUIREMENTS; SHEET A6.1 FOR MATERIALS SCHEDULE), �_ <br /> Ll <br /> ASSEMBLY TO BOTTOM REF CIVIL SHEETS L 'E <br /> OF ROOF DEGK. 11. G.C. TO FURNISH AND INSTALL RIS BACKBOARD AT ISP DESK. REFERENCE MATERIALS �, o O s <br /> T-5 (REF MATERIAL FRP-I (REF MATERIAL FINISH LEGEND REFER TO CIVIL DRAWINGS FOR EXACT REQUIREMENTS FOR RAMP, STRIPING AND TACTILE SCHEDULE ON SHEET A6.1. r J _� N S <br /> - <br /> SCHEDULE) �- <br /> ADHERE PER SCHEDULE) ADHERE PER SC-1 GRIND, SEAL AND POLISH CONCRETE SURFACE LAYOUT. 12. PROTECT SURROUNDING AREAS AND SURFACES FROM DUST, CONTACT WITH OVERSPRAY 0 <br /> MANUFACTURERS MANUFACTURERS FROM DENSIFIER, PROTECTIVE SURFACE TREATMENT, &JOINT FILLER, CLEAN SURFACES u?' E <br /> j, REGOMMENDATIONS RECOMMENDATIONS SC-2 ONLY GRIND AND SEAL CONCRETE IF SIDEWALK DEPTH IS BETWEEN U-0"AND I IN FRONT OF EQUIPMENT, CURBSTOPS OR FROM DUST, DEBRIS, OIL, GREASE, CURING AGENTS,AND OTHER SURFACE CONTAMINANTS L -0 3 <br /> E \ BOLLARDS MUST BE PROVIDED ON PARKING SPACE' SIDE OF CURB. TYP. THAT MAY ADVERSELY AFFECT INSTALLTATION OF POLISHED CONCRETE. 3 <br /> ONLY SEAL CONCRETE ra.-+ � Ln <br /> 01 <br /> 13.. REFERENCE SPECIFICATION SECTIONS 033000 CAST-IN-PLACE CONCRETE AND 033536 <br /> CONTROL/CONSTRUCTION JOINTS -SEE DETAILS ON S2.1. O <br /> POLISHED CONCRETE FLOOR FINISH DATED 02-26-2018, PROVIDED BY 7-ELEVEN, FOR ALL <br /> J <br /> O O 10. ALTERNATE FLOORING FINISH- WHEN SEALED CONCRETE IS NOT APPLICABLE-8" (33%) NEW INTERIOR CONCRETE FLOORS. <br /> OFFSET RUNNING BOND PORCELAIN TILE FLOOR PER MATERIAL SCHEDULE ON A6.1. 24" EDGE oc <br /> OF TILE TO RUN PARALLEL WITH ENTRY STOREFRONT. BEGIN FULL SIZE TILE AT EDGE OF <br /> FRP-1 (REF MATERIAL ENTRY THRESHOLD ` <br /> SGHEDULE) ADHERE <br /> 1I. <br /> , <br /> PER MANUFACTURERS <br /> REGOMMENDATI ONS <br /> �D ARC <br /> 5/8" HARDIBOARD :............. ........................... ........................................................................................... h, <br /> , <br /> ADHERED TO COOLER <br /> d <br /> D <br /> T <br /> �Ci e <br /> G <br /> C� <br /> Q <br /> n <br /> VAULT. STAPLE . <br /> a __._.._............................ - C 8827 <br /> „, „w ,,.,�.__._._.� <br /> ` PERIMETER AT 12 O.G. I �,.,,,,,, .. cn Q <br /> r._ °`I <br /> c - m <br /> Sc-3 PLY € ILEI R2 KEVVA <br /> ... L o� <br /> ELECTRICAL F �vson, F <br /> P y <br /> STORAGE p °� cA� <br /> PLY ILf� ILIrIZ l L <br /> IBU ONLY @ COOLER VAULT FRC ONLY @ COOLER VAULT PLY ® 107 <br /> ............................................................................................................................. 0 SC-2 i,.........................` ,,.....,....,,,.,..,...,, li., <br /> i <br /> IBC - <br /> ,; <br /> IL�11 SIM / I. <br /> I <br /> , <br /> , <br /> 8. ... 1 x <br /> ✓/8" GYP. BD. (PAINTED 5/8" GYP. BD. (PAINTED 5/8" OYP. BD. (PAINTED SC-1 TYPICAL FLOOR ;j <br /> REF INTERIOR ELEVATIONS) REF INTERIOR ELEVATIONS) REF INTERIOR ELEVATIONS) I IBI; ® IBC GLEAN OUTS -SEE f <br /> ATTACHED W/ I" TYPE 'S' ATTACHED Al I" TYPE 'S' uj <br /> ATTACHED W/ 1" TYPE 'S' I<< I PLUMBING PLANS <br /> ALL ®ENDER ILMI FOR EXACT <br /> SGREW5 ® 5" O.G. ALONG 5GREW5 @ 8" O.G. ALONG SCREWS ® 8" O.G. ALONG RESTROOM II IX11 17 <br /> EDGES, @ 12" O.G. IN THE EDGES, ® 12" O.G. IN THE EDGES, @ 12" O.G. IN THE V_NLOCATIONS '*" <br /> FIELD OF THE BOARD. FIELD OF THE BOARD. FIELD OF THE BOARD. 109 <br /> JOINTS ORIENTED JOINTS ORIENTED JOINTS ORIENTEDIL <br /> IBG O ,` <br /> VERTICALLY AND <br /> VERTICALLY AND VERTICALLY AND <br /> STAGGERED ON OPPOSITE 5TACGERED ON OPPOSITE STAGGERED ON OPPOSITE ": ': ;=,l,yuj <br /> SIDES OF ASSEMBLY TO SIDES OF ASSEMBLY TO SIDES OF A5SEMBL.Y TO ' - TYPIGAL FLOOR j <br /> BOTTOM OF ROOF DECK. BOTTOM OF ROOF PECK. BOTTOM OF ROOF DECK. HALLWAY SINKS -SEE q -', ■♦� <br /> �3 ILAI1 110 PLUMBING PLANS \ �,. *„ <br /> `i`ll <br /> :,• -, <br /> T-2 (REF MATERIAL T-I (REF MATERIAL T-5 (REF MATERIAL FOR EXACT IN <br /> SCHEDULE) ADHERE PER SCHEDULE) ADHERE PER SCHEDULE) ADHERE PER LOCATIONSuj <br /> MANUFACTURERS MANUFACTURERS MANUFACTURERS lLtu41 <br /> RECOMMENDATIONS RECOMMENDATIONS RECOMMENDATIONS I co <br /> .................. TYPICAL TYPICAL FLOOR :r:::..... .... :}. Y <br /> I DRAINS -SEE ; `} <br /> IBC PLUMBING PLANS I <br /> ALL GEND� <br /> 'II <br /> 0 RESTROOM <br /> FOR EXACT <br /> IBC 111 ILN LOCATIONS MERCHANDISE 1' 0 Lu <br /> ......i u � � 104 <br /> I ' SC-1 IBC I <br /> REFER TO SHEET It <br /> II` SC 1 A4.1 FOR FLOOR COOLER "r O <br /> THROUGHOUT FINISHE5 (TYP) w VAULT <br /> it <br /> 5/8" MOISTURE RESISTANT 5/8" MOISTURE RE515TANT 5/8 MOISTURE RE515TANT , :€.....c........ ... << <br /> . , ._. 1 106 <br /> GREEN GYP BD GREEN GYP BD GREEN GYP BD _...._._._r.._ , m, m;;.;,' I :: <br /> ATTACHED TO METAL ATTACHED TO METAL ATTACHED TO METAL SC-3 L <br /> [t �� 1uj. <br /> STUDS W/ 1-1/4 HOT DIPPED STUDS W/ 1-1/4 HOT STUDS W/ 1-1/4 HOT {FRPI I ` ^� 0 , <br /> GALVANIZED SGREW5 @ 8" DIPPED GALVANIZED DIPPED OALVANIZED F_ <br /> O.G. SGREW5 C� 8" O.G. SGREW5 @ 5" O.G. <br /> FRP „_,,,, <br /> H � <br /> ® ._..............._ \ Z <br /> W Q <br /> i \Ki <br /> z Q It? <br /> Wuj <br /> FRP1 _ POLISH GONGRETE POST TENSION \ > C <br /> uj <br /> L <br /> ILLI ONLY @HOT FOODS ILf�1 IL2 SLAB CONSTRUCTION. DEVELOPER \ Q U <br /> PREP AREA <br /> 2 <br /> OF SHELL BUILDING WILL NOT :_ p = W <br /> LLOW SAW GUT CONTROL JOINTSZf <br /> IE A LIJ z <br /> ------- _ <br /> FRP I v <br /> 5/8" GYP. BD. (PAINTED 5/8" EYP. BD. (PAINTED SALES <br /> :.................3 iu <br /> c <br /> 1azA-1 �E Lu <br /> Z O <br /> li <br /> i......_ k � ,� T <br /> REF INTERIOR ELEVATIONS) REF INTERIOR ELEVATIONS) I (V <br /> FRP1....................... .........?-` BACK SC-1 \ F- ,- v> <br /> ATTACHED W/ I" TYPE 'S' ATTACHED W/ I" TYPE 'S' € <br /> SGREW5 @ 8 O.G. ALONG SGREW5 g 8 O.G. ALONG ; <br /> EDGES, @ 12" O.G. IN THE EDGES, @ 12" O.G. IN THE ROOM I IN <br /> IN <br /> FIELD OF THE BOARD. FIELD OF THE BOARD. v, � <br /> 103 , � REVISIONS. <br /> JOINTS ORIENTED JOINTS ORIENTED FRP1 FFICE SC-2 `r <br /> I SIM <br /> IKI <br /> 14 � F,, <br /> VERTICALLY AND VERTICALLY AND I <br /> FRP1 ; 8. <br /> L <br /> 5TAGC-�ERED ON OPPOSITE STAGGERED ON OPPOSITE 112 <br /> SIDES OF ASSEMBLY TO SIDES OF ASSEMBLY TO SC 2 FRPI ILM2 <br /> BOTTOM OF ROOF DEGK. BOTTOM OF ROOF DEGK,. <br /> _L AlL <br /> PAINT ABOVE FRP (REF, PAINT ABOVE FRP (REF. I FRP1 - <br /> I <br /> INTERIOR ELEVATIONS) INTERIOR ELEVATIONS) <br /> P \t STORAGE L 1 <br /> 105oPIII L <br /> 1114 DRANK: 0. MEDIA <br /> U; <br /> FRP1 ENTRY ILMd2 P SC-2 <br /> ry <br /> 101 DATE: 01/10/2018 <br /> O 0 W <br /> o p sc-1 <br /> >_ <br /> { , Ip1 ILM2 3 ILfrl2 ILkl2 P J FILE: 42-7-A43 <br /> T-I (REF MATERIAL <br /> _ 1:.._L.' �LI JOB: -10.427 <br /> FRP-I (REF MATERIAL FRP-A (REF MATERIAL SGHEDULE) ADHERE PER -- -- -- -_ __..... _ _-- <br /> SCHEDULE) ADHERE PER SCHEDULE) ADHERE PER <br /> MANUFACTURERS <br /> MANUFACTURERS MANUFACTURERS <br /> RECOMMENDATIONS _._._.................................................................................................................................... > <br /> RECOMMENDATIONS <br /> RECOMMENDATIONS ONS <br /> 5/8" MOISTURE RESISTANT <br /> GREEN CYP BD <br /> NORTH WALL AND <br /> ATTACHED TO METAL <br /> STUDS W/ 1-1/4" HOT DIPPED <br /> P- <br /> 6ALVANI ZED SGREW5 @ 8" ' <br /> FLOOR FINISH <br /> � IS <br /> O.G. <br /> " PLAN <br /> FRP IBC ONLY @ RESTROOMS <br /> . .I <br /> ' �2 <br /> I <r w <br /> 1? 1" SUBSTRATE AND WALL FINISH TYPES g 1,4°' WALL AND FLOOR FINISH PLANA4 . 3 <br /> �u <br />