Laserfiche WebLink
24"OAST IRON FLUMBIN6 6ENER4L NOTES FLUMBIN6 LEGEND <br /> FRAME k COVER <br /> WITH GASKET <br /> (GASTIGHT)STANDARD I. SCOPE: 51'I'1130L ABBREVIATION DESCRIPTION .R <br /> AS xrgDlReo A COMPLETE DOMESTIC PLUMBING SYSTEM 45 GFN`ERALET DfLNfATED ON THE <br /> SIDE VIEW PLUMBING DRAWINGS,INCLUDING 5ERVIGF PIPING AND FINAL CONNECTIONS TO <br /> G(ITAWAY (4T EXTRA OOSR) EQUIPMENT FURNSHED AND II45TALLED BSS SOIL, WASTE OR SANITARY SEWER BELOW FLOORY OTHER TRADES AS MAY BE SHOWN ON 2 <br /> �..� THE ARCHITECTURAL, ELECTRICAL OR OTHER DRAWU4G5 OF THE CONTRACT GW GREASE HA57L BELOW FLOOR <br /> WARDOCUMENTS, ____ <br /> 2m 06 wa 6, - 1. CALIFORNIA CODE OF RF.GULATIGN5: ------ V VENT PIPING <br /> VARIABLEI _ 2432-OB PoSFlt-6- AEE NOT WATER DISTRIBUTION AND CIRCULATION LINES SHALL BE INSULATED IN - CIH COLD WATER <br /> 17"MINIMUM 24.' ACCORDANCE WITH SECTION 170.3 OF T14E CALIFORNIA CODE OF REGULATIONS,TITLE <br /> Sur �� 24,PART 6, SUEICHAPTER 3. ---— CWF COLD WATER FILTERED - <br /> 3. ALL PLLMMDING FIXTURES t EQUIPMENT USED(E.G,SHOWERHFADS;LAVATORY --- IN IV, 140' <br /> ""r enan� ( 1 NOT WATER SUPPLY <br /> FAUCETS,SINK FAIKFT AND WATER HEATERS}SHALL HAVE DEER CERTIFIED 70 THE E <br /> CALIFORNIA ENERGY COMMISSION BY ITS MANUFACTURER TO COMPLY WITH TRE "WR HOT WATER RETURN <br /> W-0- EFFICIENCY STANDARDS FOR SUCH APPLIANCES_ A G NATURAE GAS-LOW PIZE55URE <br /> 4' CCIDE'' HFaE-IF-3F-X-X-N-1HI-- (E') EX15TING TO BE REMOVED <br /> 5,-E" 4'-H" ALL YORK,MATERIAL,AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED IN <br /> COMPLIANCE WITH THE FOLLOWING CODES A5 ADOPTED AND AMENDED BY THE —D-GR-IW— D OR IN DRAIN OR INDIRECT HA5TF k <br /> INSPECTING AUTHORITY HAVING AURI5DICTION. NOTHING IN THESE PLANS 15 TO BE �p CD CONDENSATE DRAIN <br /> L n I, <br /> CONSTRUED TO PERMIT THE IN5TALLATION^OF WORK,MATERIAL OR EQ11Pr1S T NOT - <br /> CONFORMING TO THESE OR OTHER CODE5 APPLILABLF TO TW5 PRDIFCT. —... OLp OVERFLOW CONDENSATE DRAIN 1 v rS�j x O <br /> A. 7016 CALIFORNIA ADMINISTRATIVE CODE(CAC)PART 1,TITLE 24, SD, RWL STORM DRAIN, RAINWATER LEADER A4- UT L, Sri <br /> PIPE THE 7 <br /> CALIFORNIA CODE OF RFGUTATION5(CCR) OFL RAINWATER OVERFLOW LEADER STORM <br /> C-�-- e, CALIFORINIA BUILDING CODE(CBC.}PART 2,TITLE 24,CLR BASED ON �N � d <br /> A OI UTLET © AD,Al"AACCESS TAT7R,ACCESS PANEL , <br /> AND FITTINGS THE 01P 5 INTERNATtONA1 BUILDING CODE(IBC) � rte"] -- <br /> I I I I STANDARD C, 2016 CALIFORNIA FLFLTRICAL CADS(CEL)PART 5,TITLE 24,CCR BASED AC AIR CHAMBER 4 V1 O W <br /> ON THE 2014 NATIONAL ELECTRICAL CODE(NEC) -T, I <br /> 1C�: <br /> ANV ANGLE VALVE CU U)N o <br /> D. ZU16 U 2016IFORNIAUNI MECHANICAL CODE(CMC)PART 4,TITLE 24,CCR BASED yr <br /> 1 ONTNf 2015 I1r'1FDRM MECHANICAL CODF(DML) AO ALVASTAT V E. 2016 ) CCR Bk5ED IS r I L____-- J L_____J G. 016 CALIFORNIA FIRERGY E C)(PARTP9,R6,TITLEL24 C R, ON YHE AD AREA DRAIN � o p I4'-0 THE 2115 UNIFORM PLUMPING CODE{UPC. <br /> I I P 2016 CALIFORNIA ENERGY CODE(CFL)PART L,TITLE 74 CCR. AAV AUTOMATIC AMR VENT t �j"� "" v N q rn <br /> _____ _ --067- EV BALL VAI.VF N 3 <br /> 2015 INTERNATIOIAL FIRE COPE(IFC) J J 3 <br /> TOP VIEW LIQUID CAPACITY: 750 GALLONS. H. 101 <br /> 6 CALIFORNIA GREEN BUILDING 57ANDARDS{(.Cd35C}PARI II,TITEF 2A, BRAWA-TOP CONNECTION <br /> (COVERS Ar RISERS REMOVED) CCR -� BRANCH-BOTTOM CONNECTION <br /> DESIGN LDAD: H-20 TRAMC FROM <br /> M'TO 6'OF SOIL_COVER. 5. WORKMANSHIP, 'J-� BRANC4I-SIDE CONNECTICH 5 <br /> ALL HOW SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER ACCORDING TO 9 <br /> FOR COMPLETE CN AND PRODUCT - BfY BUTTERFLY VALVE <br /> INFORMATION CONTACT JENSEN PRECAST. THE BEST,FIXTURES, <br /> PRACTICE BY TC,SMASKILLEDBE L THE PARTICLEVEL, LARSQUARE <br /> TRADE. <br /> EQUIPMENT,FI%TEIRES,PIPING,ETC„SHALL BE PLUMB,LEVEL,SOJARE AND/OR ] GOP CAP ON END OF PIPE <br /> CENTERED,ETC_EQUIPMENT TO BE INSTALLED IN STRICT COMKIAWF WITH , C8V CALIBRATED BALANCE VALVE <br /> MANUFACTURERS RECOMMENDATIONS. <br /> 6. EXISTING INFORMATION- %--- CB,RO CATCH BASIN, ROOF DRAIN 9 <br /> bREAS INT�RG�PTOR GALLS LOCATION,SIZE,ELEVATION,MATERAS, ETC.,OF EXISTING UTILITIES 15 PROVIDED CKV CHECK VALVE <br /> FROM SOURCES DFFMFD RELIABLE BUT 15 NOT GUARANTEED.THE CONTRACTOR <br /> SHALL FIELD VERIFY ALL DATA BEFORE PROCEEDING WITH ANY WORK. NO EXTRA --�--- CP CIRCULATING FJMP <br /> ALL SIZING PEP.2016 CALIFORNIA PLUMBING CODE, COST WILL BE ALLOWED FOR SERVICES NOT A5 SHOYPN_ <br /> TA}iLE 1014.3,6 '1. PERMITS ANP UTILITY SERVICF fFFS: -HI Co Co CLEANOUT PLUG <br /> GRAVITY GREASE INTERCEPTOR 511ING THE PLUMBING CONTRACTOR 59ALL ARRANGE AND PAY FOR ALL PERMITS, -{ CR CONCENTRIC REDUCER <br /> INSPECTIONS,AND SERVICE CHARGES REQUIRED FOR THE INSTALLATION OF THE <br /> DESIGN CRITERIA WORK d DLA pIAnETER E <br /> DRAINAGE FIXTURE UNITS FLOOR DRAIN 2 FU N I • 2 FU 6. ACCURACY <br /> MCP BI SINK 2 FU N I 2 FU �- ER ECCENTRIC REDUCER <br /> MCP SINK 3 FU N I 3 FU - PLANS ARE DIAGRAMMATICHfWALLS, THE ION,FIXTURES, <br /> SHALE CONFIRM ALL DIMENSIONS FL FLE%OBLE CRNNFCTOR <br /> SODA/COFFEE I FU N 2 2 FU AND LONS157E O WALLA,PARTITIONS,RTO COM ETON AGAINST DESMON PLANS �1 Nr <br /> FOR CONSISTENCY AND ACCURACY PRIOR TO ITP TRAP A WORK. +O FCD FLOOR CLEANO7Tui co <br /> O <br /> 9 Fu 9. PROVIDE AND NSTALL CONDENSATE DRAIN WITH TROP A7 FACE!M 1AIr4A UNIT PER THF. FD FLOOR DRAM <br /> 21 FU MAX.,750 GALLON UPC AT LOLATIDNS 54YJWN ON DRAWINGS,COORDINATE WITH MECHANICAL <br /> (INTERPOLATED FROM 11143,6) CONTRACTOR. F5 FLOW SWITCH <br /> 10. PROVIDE AND INSTALL ACCESS PANELS FOR ALL SHUT-OFF, I5O.ATION,OR BRANCH <br /> VALVES NOT READILY ACCESSIBkF.ALCE55 PANFLS SHALL BE PROVIDED AND GCK GAGE COCK V/ <br /> MSTALLED AT ALL TRAP PRIMER VALVES AND WATER HAMMER ARRESTORS. --per- GV GATE VALVE <br /> //��,,��\\ nn����++++'////��L� C �I+�� �+ Y 1� € 11. ALL PIPING PASSING THROUGH CONCRETE FLOORS SHALL BE SLEEVED TO PROTECT <br /> SE INTERCEPTOR ERCEP I OR DETAIit PIPIIK AGAINST BREAKAGE. -+-C-1... GSCK, PC GAS COCK,PWG COCK � W p <br /> SCALE NONE <br /> 11, HORIZONTAL DRAINAGE PIPING LESS THAN 4'IN DIAMETER SHALL BE SLOPED AT A GPR GA5 PRESSURE REGULATOR Z <br /> PO 0 MINIMUM OF 1/4'PER FOOT(2I)DRAINAGE PIPING 4°AND LARGER SHALL BE GL.V. (LOSE VALVE <br /> - <br /> SLOPED AT A MINImum OF 1/B'PER FOOT.(IE). „�� <br /> 13. ALL PLU111%FIXTURES AND PIPING SHALL BE LISTED BY AN APPROVED LISTING GCI] GRADE LEFANOUY UJ <br /> AND TESTMG AGEWT AND PRO'ERLT LABELED, _ HB NOEL BIBS Lu <br /> �— AN PIPE ANCHOR z <br /> FIX'T'URE CONNECTION 5GH!l17ULE PS PIPE GUIDE Z <br /> 0 POC POINT OF CONNECTION O <br /> 5YM eRAMfx TRAP VENT O <br /> FIXTURE WASTE ME)WATER HOT WATER � PRV PRESSURE REDUCING VALVE 0 <br /> rurLLr 6RA11PI am#T gV,ap1 pYfLCF PG PRESSURE GAUGE E� c <br /> HATER CLOSET(F.T.)Y� WC 4' 3' INT, 2" Id' ' -- -- --OR , RV a TtP RELIEF VALVE OR TEMPERATURE t PRESSURE RELIEF VALVE t <br /> L_.,. <br /> LAVATORY _ L 2' 11? IV IV YU' k,' V k"' �E- SV SOLENOID VALVE yg <br /> 51KK 5 ....7'- .ITN' IV IFN 'y' k' k' �' �}_... STIR STRAINER t¢¢_ � J <br /> MOP SINK MS W S' S' 2' '6� r F1� I � �... TH THERMOMETER S 4 Lu W <br /> -. <br /> FLUOR DRAM .-.T_ FD 2' 7e 2e it, __ __ __ __ -TP-.... TP TRAP PRIMER E <br /> FLOOR SINK F5 3' Y 3' 2' -- -- -- -SII- ON UNION OR FLANGE - <br /> . 0 VTR VENT THRU ROOF Fp W u- <br /> HOSE BIBB HB -_ -_ e , __ YICS O � w <br /> ____,.._.... �1 � -- NSI O HALL CLEANOUT E v <br /> ui <br /> TRENCH DRAIN TD 2" 2' 7 Ik' _ <br /> Y <br /> FLUM5IN6 MATERIAL SPECIFICATIONS SHEET INDEX �� h od <br /> -- <br /> A DHy r SHLET Np, pF.SLRIPTIDN <br /> PIPE ABS SU 4D PIPE PER ASTM D 2661-W -----_ EGENO.. <br /> F17 NG5:ABS SCH.40 FITTINGS PER D 2661-2011 POD PLUMBING-LEGEND, UND AND PLAN ULEB F <br /> PLO PLUMBING-UNDERGROUND FLOOR PLAN L <br /> 1-.p:N'1ESTIC WATER t¢ <br /> .TYTER TYPE L PER ASTM BBB-2009 <br /> L1111NGS:WROUGHT COPPER PER ASME 516,27-2013 <br /> IN5UE.ATION:INSULATE HOT WATER AND H07 WATER RETURNS A5 FOLLOHS. <br /> PIPE 1 310-1°FIBERGLASS INAND ALL-SERVICF-JACKET <br /> PIPE 7 I' -I-IINSULATION AND <br /> FIBERGLASS INSULATION AND ALL-SERVICE-_"FT <br /> ski to" � FILE <br /> qe <br /> q6 FILE: <br /> �� Qp(AFSS1p4, i <br /> i�E � Eat xe <br /> r g <br /> NE`NECNANGr�`r PLUMBING <br /> Yrf OF CALO55RN LEGEND, NOTES <br /> F 3 SCHEDULES <br /> Conwlfilla Mecl�rvcol EnpinemO �� <br /> / *«ass,anw w eoeaw.I �� <br /> P0.0, �a. <br />