Laserfiche WebLink
BUILDING AND SAFETY CONS RUCTION <br /> 1. ENTRANCE DOOR TO BE SELF LOSING. <br /> 2. ALL COMPRESSOR UNITS SHALL BE SEPARATED FROM FOOD PREPARATION AND STORAGE AREAS WHILE BEING MADE ACCESSIBLE FROM THE OUTSIDE. <br /> 3. ALL DOORS SHOULD CLOSE TIGHTLY AND ALL OPENINGS IN OR AROUND PIPES,FLOORS AND WALLS ARE TO BE TIGHTLY SEALED AND SECURED FROM RODENTS. <br /> 4. SINKS ARE TO BE CONSTERUC ED OF STAINLESS STEEL METAL WITH MIXED HOT/COLD FAUCETS.MUST INCLUDE STAINLESS STEEL DRAINBOARDS WITH A SLOPE 0.125"(1/8")PER FOOT. <br /> 4.1 ALL FOOD CONTACT SURFACES,COUNTER TOPS,FOOD COMPARTMENTS,WALLS AND CEILINGS ARE STAINLESS STEEL 304#4 RADE. <br /> 5. MUST INCLUDE A SINGLE SERVICE SOAP AND TOWEL DISPENSER <br /> 6. FLOOR SURFACE IS TO BE IMPERVIOUS,SMOOTH AND EASY TO CLEAN.SHOULD PROVIDES EMPLOYEE SAFETY FROM SLIPPING. <br /> 7. ALL EQUIPMENT TO BE EASILY LEANABLE WITHOUT CHANNELS OR CREVICES.THERE MUST NOT BE EXPOSED THREADS,NUTS, OR RIVETS THAT MAY INTERFERE WITH PROPER CLEANING OF <br /> EQUIPMENT.INSULATION BELOW GRIDDLE IS TO BE COMPLETELY COVERED AND UNEXPOSED. <br /> B. ALL CONSTRUCTION JOINTS AND WELD SEAMS TO BE SEALED,SMOOTH,AND CLEANABLE. <br /> 9. FLOOR MOUNTED EQUIPMEN1 TO BE SEALED TO THE FLOOR OR ELEVATED AT LEAST 6"OFF <br /> THE FLOOR ON CLEAN,ROUND,METAL LEGS. <br /> 10. ALL EQUIPMENT TO BE SEALED TOGETHER OR SPACED A MINIMUM OF 4"APART FROM EACH OTHER. <br /> 11. AN ACCURATE THERMOMETER IS TO BE PROVIDED IN ALL REFRIGERATION UNITS. <br /> 12. ALL LIGHT BULBS AND TUBES 10 BE ENCLOSED IN PLASTIC. <br /> 13. ALL SERVING OPENINGS ARE TO BE EQUIPPED WITH SELF-CLOSING SOLID WINDOWS OR SCREENS. <br /> 14. WATER HEATER SHALL BE CAPA LE OF PROVIDING HOT WATER TO THE SINK AT A MINIMUM OF <br /> 4.5 GALLONS CAPACITY.AN 114STANTANEOUS WATER HEATER SHOULD BE CAPABLE OF PRODUCING WATER AT 120 F. <br /> 15. FLOOR COVERING MATERIALS ALL EXTEND UP THE SIDES OF THE WALLS A MINIMUM OF 4". <br /> 16. WALL AND CEILING SURFACE 11 HOULD BE DURABLE,IMPERVIOUS,SMOOTH AND EASILY CLEANABLE. <br /> 17. EACH SERVICE WINDOW OPEI,ING SHALL BE LIMITED TO 216 SQ.INCHES.A MINIMUM DISTANCE OF 18" <br /> MUST BE MAINTINED BETWEEI, EACH OPENING. <br /> 18. THE MINIMUM CEILING HEIGH r IS 76"HIGH. <br /> CAL CENTRAL CATERING TRAILER <br /> 19. AISLES ARE TO BE A MINIMUM OF 30"WIDE AND 76"IN HEIGHT. 3511 Finch Rd.#A <br /> 20. WALLS AND CEILING ARE TO HAVE A STAINLESS STEEL METAL FINISH. MODESTO CA 95357(866)549-1550 <br /> 21. FLOOR FINISH SHALL BE OF DI kMOND PLATE ALUMINUM. For. Project Number. <br /> 22. CEILING VENT SCREEN MESH SHALL BE A MINIMUM OF 16-MESH PER SQUARE INCH. Fangudes Meats And Catering Inc <br /> MODEL TRK16-8.5 DATE: 4/07/2016 <br /> SHEET2 Of 15 Design by:Flavio Rios <br />