Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORNr'. , <br /> F� UNDERGROUND STORAGE TANK '` <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(one form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections 1,11,111,IV,and IX below) '170 <br /> ❑ 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ® 5.CHANGE OF INFORMATION <br /> 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ S.UST REMOVAL 'I Ay 1 7 2n1l <br /> DATE UST PERMANENTLY CLOSED: 430. DATE EXISTING UST DISCOVERED: 430h <br /> . . . :..,'. '. •::FACILITYJNFORMATIOJV , <br /> FACILITY ID d(agency Use Only) <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> Arco Manteca <br /> BUSINESS SITE ADDRESS 1°1 CITY 104 <br /> I711 E.Yosemite Ave Manteca <br /> II.TANKDE$CRIIITION <br /> TANK ID A / � 412 TANK MANUFACTURER 433 TANK CONFIGURATION.THIS TANK IS 414 <br /> �-Premium D S A S"ISI ®1.A STAND-ALONE TANK <br /> ❑ <br /> 2.ONE M A COMPARTMENTED UNIT. <br /> Complete one page Ibr each com enment in the unit. <br /> DATE UST SYSTEM INSTALLED 475 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 11894 <br /> ✓ ,,s , b ;., �� ' , 'I;�'. '' ;YII NX-0 CONTENTS ;ri s;nl ,s s <br /> TANK USE Nla.MOTOR VEHICLE FUELING [I lb.MARINA FUELING ❑ lc.AVIATION FUELING 439 <br /> C33. MOT-OR <br /> PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used oi) ❑ 5.EMERGENCY GENERATOR FUEL(HSC 525261.5(c)3 <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439a <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ® Ib.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440m <br /> NON-PEWLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTIM NON-PETROLEUMS eci : 440b <br /> s �*�;.• 's tn.irU`T•>.�jk'• : �. <br /> a =IV.: TANK CONSTRXJCTION' r <br /> TYPE OF TANK ❑ 1.SINGLE WALL El 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL N 3.FIBERGLASS ❑ 6.EXTF,R 0R MEMBRANE LINER 7.JACKETED -145 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify) 445a <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT b 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION E UIPMENT <br /> rs+i c�l <br /> ��. �Y.4 RODYICT/.r�!.A.S,�'E PIPING'GONSTRUCTipN,' <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED ®2.DOUBLE-WALLED [199.OTHER 460 <br /> SYSTEM TYPE ® L PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR 8263 a I 455 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ I.STEEL 19 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specifyy. 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® I.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d <br /> `¢ VI !ENT,VAPOR RECOVERY{VR)AND'12ISER%;FII L''PIPE PIP ING:CONSTRUQTION " ' <br /> VENT PRIMARY CONTARiMENT [IL STEEL 19 4.FIBERGLASS ❑ 10.RIGID PLASTIC [190.NONE ❑ 99.OTHER(Specify) 4644641 <br /> VENT SECONDARY CONTAINMENT 1.STEEL ® 4.FIBERGLASS 10.RIGID PLASTIC 90.NONE 99.OTHER(Specify) 464f <br /> 464n <br /> VR PRIMARY CONTAINMENT 0 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE 99.OTHER(Specify) 4645 <br /> 464 I <br /> VR SECONDARY CONTAINMENT 1.STEEL N 4.FIBERGLASS 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464h1 <br /> VENT PIPING TRANSITIOtNSUMP TYPE I.SINGLE WALL ❑ 2.DOUBLE WALL 90.NONE 4641. <br /> RISER PRIMARY CONTAINMENT C9 I.STEEL Ll 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 46ei <br /> 464.1 <br /> RISER SECONDARY CONTAINMENT L STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 4601 <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET 0 3.STRIKER PLATE/BOTTOM PROTECTOR 0 4.CONTAINMENT SUMP 451.-c <br /> ,VII UND :RWENSER:CONTXINIVIENT(UDC) <br /> CONST RUCTION TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS [190.NONE 469. <br /> CONSTRUCTION MATERIAL ❑ L STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTI IER(S eciry) 4696-° <br /> CORItpSIQN.PROTi•±CTION <br /> STEEL CONfPONF.NT PROTECTION ❑ 2.SACRIFICIAL ANODES) ❑ 4.IMPRESSED CURRENT N 6.ISOLATION 448 <br /> l 11X. .APPLiCAP . SIGh{ATURE <br /> CERTIFICATION: 1 certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance with legal requirements. <br /> 4-10. <br /> APPLICAN IGNATURE DATE <br /> y 4/15/2011 <br /> APPLICANT NAME(?6) 471' APPLICANT TITLE 472, <br /> Gurdeep Singh President <br /> UPCF UST-B-2/3 Rev.(12/2007) <br />