Laserfiche WebLink
L 1000 <br /> Dimensions <br /> 1-POINT 3-POINT <br /> Specifications <br /> Power Input <br /> 120 VAC:t 10%,60 Hz <br /> Fuse—.10 AMP,AG-SLO BLO <br /> 8.00' s.oa <br /> Power to Field Sensor 8.75 00 <br /> Low electrical energy;12 VDC at 15mA <br /> provided by control unit to each sensor ® Q O <br /> switch.Safe for Class I,Division 1,Groups A, <br /> B,C,D;Class II Division 1,Groups E,G. <br /> Control Relay Output -4.00 --{ BOTTOM OF case 10.E ---- <br /> Dry switch contact—SPDT per point,rated 3 6.00 2 HOLES FOR <br /> AMPS at 120 VAC;selectable either normally 1W CONDUIT HUBS 10,35 <br /> open or normally closed. <br /> Response Time VAILLAB OR <br /> Typically 1/2 second.Automatic horn silence 0.313 HIGH OR LOW <br /> option,adjustable 30 seconds to 3 minutes. MTG HOLES FUNCTIONS <br /> Indicators/Controls ANNUNCIATOR <br /> Red light indicates alarm condition ERO <br /> PNEIIMRCAfOR <br /> Horn signals audible alarm—85dB min. ANNUNCIATOR PNE(IM <br /> Reset button silences alarm SILENCE SWITCH <br /> Test button tests alarm circuits CIRCUIT TEST <br /> SWITCH <br /> Temperature O O <br /> -40°F to+160°F(-40°C to+71'C) <br /> Enclosure BOTTOM OF CASE <br /> NEMA 4-weatherproof standard 2-POINT 4"HOLES FOR 4-POINT <br /> 112' CONDUIT HUBS <br /> Installation <br /> Wall mount standard <br /> DIMENSIONS ARE IN INCHES <br /> Weight OVERALL DEPTH-4.75 INCHES <br /> 6 lbs.(2.7 kg.)approx.—small case <br /> 11 lbs.(5 kg.)approx.—large case <br /> Sensor Cable Sample Specifications <br /> Standard 2 conductor#18AWG Provide and install for each tank A (high/low)level/overfill <br /> Up to 5000 feet(by customer) prevention alarm/control console.Console should display a visual indication <br /> OW Pan of alarm condition and include an audible alarm horn with reset button.Visual <br /> Model DescriptionNumber, indication should remain on until alarm condition is corrected.A test button on <br /> the alarm console should be provided to function test audible and visual alarm <br /> 1-01001 Single Point" LC1SA circuits.The console should provide a SPDT switch output,rated 3 AMPS at <br /> LC1062' Two Points LC2SA 120 VAC for controlling external devices.Electrical circuitry to tank mounted <br /> L01003 Three Points LC3SA process sensors should be listed intrinsically safe for hazardous areas.The <br /> LC1004 I Four Points ` LC48A sensor wiring must be run in separate conduit containing no line voltage. <br /> Specifications subject to change without notice. Alarm console should consist of solid state electronic circuitry operated from <br /> 120 VAC power,housed in a weatherproof enclosure,model <br /> File No.1Q3A4.AX (see model number table) manufactured by the Pneumercator Co., <br /> Farmingdale,NY 11735. <br /> APPROM Distributed by: <br /> /I, ME CAT <br /> Liquid LevetFUControl Systems <br /> PNEUMERCATOR COMPANY, INC. <br /> 120 Finn Court,Farmingdale,NY 11735 <br /> (631)293-8450 FAX(631)293-8533 <br /> httpJ/www.pneumereator.com <br /> B-1-01000 Printed in U.S.A.10/03 <br />