My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
6970
>
2300 - Underground Storage Tank Program
>
PR0231833
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:53:51 PM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231833
PE
2361
FACILITY_ID
FA0003874
FACILITY_NAME
Meineke Car Care Center # 4130
STREET_NUMBER
6970
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
02
SITE_LOCATION
6970 WEST LN STE 130
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231833_6970 WEST_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
477
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
initial repair should be limited to the exchange of <br />modules and verification of proper wiring of all <br />incoming field connections. <br />4.2 Annunciator Module <br />Troubleshooting of the annunciator module <br />should be carried out systematically, since this <br />module operates in conjunction with the <br />X53-2000 Field Isolator and the intrinsically safe <br />24 VDC power supply. <br />In the event of a malfunction of this module, <br />check field wiring to the input terminal connector <br />of the X53-2000 Field Isolator (schematic <br />X76-2001). Check fuse in the power supply and <br />measure with a DC voltmeter the voltage across <br />the output of the power supply, confirming 21.6 <br />to 30 VDC. <br />Replace the X53-2000 Field Isolator module. If <br />this does not solve the problem, the cause is in <br />the annunciator module, which will have to be <br />replaced. <br />The Ronan Series X76S Leak Detector Monitor is <br />a four -point annunciator system of general-purpose <br />design equipped with certified, intrinsically safe <br />barriers to interface with field contacts that are <br />located within a hazardous area as described in <br />section 1.0. The field contact, when transferring from <br />normally open or normally closed to its off -normal <br />state, will be visually indicated via the light -emitting <br />diode and the audible buzzer will sound. The front - <br />panel -mounted pushbutton allows the operator to <br />acknowledge the alarm, thereby changing the flashing <br />LED to steady -on and silencing the audible alarm. The <br />test pushbutton, if pressed, will actuate all alarm <br />points to verify proper operation of the logic and the <br />LEDs. <br />The Model X76S, used as a leak detector, <br />monitors liquid levels in secondary underground tanks <br />and/or ground wells. The system finds applications in <br />gasoline and oil storage facilities to detect these leaks <br />in time to prevent leakage or seepage of hazardous <br />liquid into the underground water table. <br />The secondary containment tank leak monitor consists <br />of liquid -level sensors and alarm annunciator modules, <br />located in the Ronan X76S system. The liquid -level <br />sensor monitors the area between the inner and outer <br />tank for possible spillage. Should a leak occur, the <br />product will be contained in the outer shell and the <br />X76S alarm annunciator module will indicate an alarm <br />via the system's buzzer and flashing LED, specifying <br />which tank has a leak. The X76S will also indicate an <br />alarm should the outer shell leak and allow ground <br />water to seep into the tank. <br />7.0 SPECIFICATIONS <br />7.1 System, Model X76S <br />Power: 115 VAC, 60HZ <br />Power Consumption: 100 VA <br />Operating Temperature: 32 to 165°F (0 to 75°C) <br />Dimensions: <br />9 x 9.5 x 4.2 inches (22.86 x 24.13 x 10.67 cm) <br />Mounting: General purpose area; wail mount <br />-<FM> Approved: File J.I. 2N4A1.AX <br />7.2 Annunciator Module <br />Field Sensor: Dry contact <br />Field Sensor Voltage: 115 VAC (supplied <br />by X76S) <br />Number of inputs: One per module <br />-e> Approved: File J.I. 2N4A1.AX <br />7.3 Intrinsically Safe Field Sensor <br />Interface Module X53 <br />Number of Inputs: Two per module <br />Sensors Voltage: 24 VDC, current limited <br />Sensors: Dry contact <br />Output Interface to Alarm Module: Relay <br />contact; normally open/normally closed; <br />selectable <br />Power Consumption: 750 mW per input <br />Supply Voltage: 24 VDC from IS power supply <br />FM Approved: File J.I. 2N4A1.AX <br />7.4 Power Supply IS (Intrinsically Safe) <br />Power Input: 115 VAC <br />Output Voltage: 24 VDC <br />FM Approved: File J.I. 2N4A1.AX <br />7.5 Vapor Sensor, Model HV <br />Detection Method: Solid-state diffusion type <br />Detectable Gases: Hydrocarbons, gasoline, <br />solvents, carbon monoxide, methane, ammonia, <br />sulfur dioxide, hydrogen sulfide <br />Detectable Range: 0-100% LEL <br />Accuracy: ±5% <br />Response Time: Less than 15 sec to 90% full <br />scale <br />Sensitivity: 5 ppm <br />
The URL can be used to link to this page