Laserfiche WebLink
IED PROGRAM CONSOLIDATED` <br /> TANK <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(check on that ) Paga-'of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE X1.PRESSURE [12.SUCTION [33.GRAVITY 458 ❑1.PRESSURE ❑2. SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION [31.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑1.SINGLE WALL [395.UNKNOWN 462 <br /> MANUFACTURER)<2.DOUBLE WALL [395.UNKNOWN [32.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER A M E A O 461 MANUFACTURER 463 <br /> ❑1.BARE STEEL ❑6.FRP COMPATIBLE w/100% METHANOL [31.BARE STEEL [36.FRP COMPATIBLE W/1om METHANOL <br /> [32.STAINLESS STEEL ❑7.GALVANIZED STEEL I ❑Unknown [32. STAINLESS STEEL [37.GALVANIZED STEEL <br /> [33.PLASTIC COMPATIBLE W/CONTENTS ❑99. Other [33. PLASTIC COMPATIBLE W/CONTENTS [38.FLEXIBLE(HDPE) ,Q 99. OTHER <br /> Ix 4.FIBERGLASS [38.FLEXIBLE(HDPE) [34. FIBERGLASS ❑9.CATHODIC PROTECTION <br /> [35.STEEL W/COATING [39.CATHODIC PROTECTION 464 [35. STEEL W/COATING E395.UNKNOWN 465 <br /> VIL PIPING LEAK DETECTION(Check a0 that lyi(Ade' ' ion of the inonito' am shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING, 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST FEW AUTO PUMP SHUT ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ <br /> AUDIBLE AND VISUAL ALARMS. AUDIBLE AND VISUAL ALARMS. <br /> [32.MONTHLY 0.2 GPH TEST ❑2. MONTHLY 0.2 GPH TEST <br /> ❑3.ANNUAL INTEGRITY TEST(0.1GPH) ❑3.ANNUAL INTEGRITY TEST(O.1GPH) <br /> [34. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> 0 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING <br /> INTEGRITY TEST(0.1 GPH) 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): [36. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> [37.SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW ❑7. SELF MONITORING <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑8. DAILY VISUAL MONITORING <br /> [39. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WI1' AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITE AUDIBLE AND VISUAL <br /> ALARMS AND(Check oro) ALARMS AND(Cluck one) <br /> Xa. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS :JJ C Q IV ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b AUTO PUMPSHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑c. NO AUTO PUMP SHUT OFF ❑c NO AUTO PUMP SHUT OFF <br /> X11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT ❑11. AUTOMATIC LEAK DETECTOR <br /> OFF OR RESTRICTION <br /> ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS [313. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> [314. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF* ❑14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION [315. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑16.ANNUAL INTEGRITY TEST(0.l GPH) <br /> E317. DAILY VISUAL CHECK ❑17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE E34.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 [32.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER/MONITORING <br /> ❑3.CONTINUOUS DISPENSER PAN SENSORIST AUTO SHUT OFF FOR <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS •NONE 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the Wbrtnntion provided hetein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNER/OPERATOR DATE 05--A4-0+' 470 <br /> N <br /> NAME OF OWNER/OPRATOR(print) TITLE OF OWNER/OPERATOR 472 <br /> C'1< Co J 7 1 s4 e5 Mn� <br /> UPCF(1/99'revised) 175 Formerly SWRCB Form B <br />