My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
515
>
2300 - Underground Storage Tank Program
>
PR0231400
>
COMPLIANCE INFO_1985-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2005
RECORD_ID
PR0231400
PE
2361
FACILITY_ID
FA0003539
FACILITY_NAME
S B GAS & MARKET
STREET_NUMBER
515
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23309031
CURRENT_STATUS
01
SITE_LOCATION
515 W ELEVENTH ST STE 301
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231400_515 W ELEVENTH_1985-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
553
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06/11/2004 14:44 209-836- 130 PAGE 09 <br />WIN <br />UNDERGROUND STORAGE TANK <br />MONITORING PIAN - PAGE 2 <br />Vi, DISPENSERMONITORING <br />MONITORING OF AREAS BENEATH DISPENSER($) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) M50 <br />❑ 1. CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) <br />PANEL MANUFACTURER: �L r? / M31 MODEL M M2.a. <br />_ <br />LEAK SENSOR MANUFACTURER: M53. MODEL #(S): M54. <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ❑ a. YES ❑ b. NO M'S. <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a. YES b. NO M-. <br />WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a. YES ❑ b. NO Mv <br />[] 2. MECHANICAL. ASSEMBLY (e.g., FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: t4S8• MODEL #(S): M39, <br />❑ 3.VISUAL MONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY ptequires agency approval) M60' <br />❑ 4. NO DISPENSERS <br />❑ 99.OTHER (Specify) Mal. <br />VII. ENHANCED LEAK DETECTION <br />❑ -I W.E HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70. <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />VIII. TRAINING <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) luso. <br />1. THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Regalred) <br />2. OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />3. THE FACILITY'S BEST MANAGEMENT PRACTICES (Required a# of 1/0112005) <br />4. ® CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL. AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7.) SWRCB PUBLICATION: "WEEKLY. MANUAL TANK GAUG[NG.FOR SMALL UNDERGROUND STORAGE TANKS" <br />99. ❑ OTHER(Specify): 1 1. Mat. <br />Personnel with UST monitoring responsibilities are familiar with all of the above-documcnts rclevant to their job duties and can access those documents when needed. <br />By January 1, 2005 this facility will have a "Designated UST Operator" who has passed the operator exam administered by the International Code Council (HCC). By <br />January 1, 2005, and annually thereafter, the "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems. <br />This training will include, but is not limited to, the following: <br />9 Operation of the UST systems in a manner consistent with the facility's best management practices. <br />D The facility employee's role with regard to the leak detection equipment. <br />The facility employee's role with regard to spills and overfills, <br />? Whom to contact for emergencies and leak detection alarms. <br />For facility employees hired on or after January 1, 2005, the initial training will be conducted within 30 days of the date of hire. <br />IX. COMMENTS/ADDITIONAL INFO TION <br />Please use this section to include any additional UST system monitoring -related information (e.g.. additional information required by your local agency): Mss. <br />X. PERSONNEL RESPONSIBILITIES <br />AS OF I/1/05, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION 111 OF THE CURRENT UST OPERATING PERMIT APPLICATION — <br />FACILiTY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br />EQUIPMENT COVERED BY THIS PLAN, AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br />UST SYSTEMS IN ACCORDANCE WITH 23 CCR § 2715(b). <br />XI. OWNER/OPEI.ATOR SIGNATURE <br />CERTIFICATION: I certify that the Information provided herein is true and accurate to the best of my knowledge. <br />OWNER/OPERATOR= REPRESENTIN <br />�. ( {,Owner M" <br />DATE: Mvi. <br />r () <br />❑ Operator <br />1"l— <br />M95. <br />OWNER/OPERATO NAME (print): M92 OWNER/OPERATOR TITLE:&ML�ZL <br />Y <br />LIze 9 <br />(Agency Use Only) This plan has been reviewed and: [] Approved ❑ Approved With Conditions ❑ Disapproved <br />Local Agency Signature: Date: <br />Comments/Special Conditions: <br />SJCEUtW (07103) - 314 0723103 <br />