Laserfiche WebLink
UST <br />SYSTEM PRINTSET INFORMATION • • <br /># 4 <br /># <br /># <br /># <br />CAPACITY <br />1. <br />oo 0 <br />Four complete sets of plans (To include specification sheets and/or equipment brochures if not on file). <br />MANUFACTURER <br />2.✓ <br />!�I <br />Plans drawn to scale in non -erasable print. <br />r_COPOSITION <br />�,�(,�, �ST�£L <br />3. <br />Y// <br />Plot plan to show location and number of tanks. <br />4. <br />V <br />Tank cross-sectional diagram included on prints submitted. <br />5. <br />_4Z <br />Detail of tank, piping system, excavation and cover. <br />6. <br />V1 <br />Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br />f EK)E ).VWL,�L/.�,PLV-S <br />Article 3, Sec. 2631 (r) & 26351 <br />7. <br />V <br />Verification of product compatibility with the tank(s), piping, monitoring <br />F R 9 <br />�7t 0 <br />device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)] <br />8. <br />U.L. LISTED <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 (b) (5)] <br />9. <br />✓ <br />Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br />COMPATIBILITY WITH 100% <br />METHANOL <br />[Section 2635 (b) (6) & (7)] <br />LS <br />YES <br />10. <br />Double walled tanks using pressurer�vacuLin ing to monitor the annular space. [Section 2635 (b) (7)] <br />11. <br />Z <br />NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PHS/EHD from the testing company or owner of facility. [Health & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (g)] <br />12. <br />TANK COMPOSITION <br />TANK # <br /># 1 <br />1 <br /># 4 <br /># <br /># <br /># <br />CAPACITY <br />Otv� <br />oo 0 <br />MANUFACTURER <br />YYIVY� <br />YY�OI���AJQ <br />!�I <br />r_COPOSITION <br />�,�(,�, �ST�£L <br />81015 hL <br />RPISI%C <br />MODEL <br />SvatJ <br />Gm;RCLII <br />GL 2AUL T <br />PRODUCT <br />VNL, REG <br />f EK)E ).VWL,�L/.�,PLV-S <br />CORROSION PROTECTION <br />VIA P. <br />F R 9 <br />�7t 0 <br />U.L. LISTED <br />VL <br />VL 5% <br />COMPATIBILITY WITH 100% <br />METHANOL <br />VAS <br />1 <br />LS <br />YES <br />13. TANK(S) TO BE INSTALLED <br />VA. Steel -clad with fiberglass reinforced plastic. <br />B. Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (4)] <br />C. Fiberglass [Sections 2635 (3) and 2631 (p)] <br />(1) Striker plate dimensions and materials. <br />t/' (2) Striker plate under all accessible openings. <br />(3) Installation instructions require an air test and soap bubble test prior to installation. <br />0 D. Non -clad steel tank [Section 2635 (b)] <br />(1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />(2) Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) Document stating inspection method and frequency (minimum semi-annual inspection requirement). <br />H <br />