Laserfiche WebLink
MONITCING SYSTEM CERTIFOATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION /TEST DATE: April 23, 2012 <br />Al. FACILITY <br />Name Quik Stop Market #132 <br />Address 3555 W. Hammer Lane, Stockton, CA 95219 <br />Phone # 510-657-8500 <br />Contact Michael Karvelot <br />A2. OWNER <br />Name Quik Stop Markets, Inc. <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone# 510-657-8500 <br />Contact Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Tank #1 (Product): Gasoline - 87 <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />In -Tank Gauging Probe <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />April 18, 2012 <br />■ <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Garret Backus <br />Model: 0794390-409 <br />Contact <br />Dulcinea Coven <br />Phone # <br />209-468-8257 <br />Piping Sump / Trench Sensor(s) <br />Phone # <br />916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to Indicate equipment Inspected/serviced) <br />Bi- TANKS <br />132' UI,I+CIV`StK,/11L7C'!S <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Tank #1 (Product): Gasoline - 87 <br />Dispenser <br />■ <br />■ <br />❑ <br />Tank #2 (Product): Gasoline - 89 <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390-409 <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390-409 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />■ <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />I 1 ❑ <br />Other (specify equipment in Section E) <br />Model: <br />Tank #3 (Product): Gasoline - 91 <br />Tank #4 (Product): <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390-409 <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: FE Petro STP -MLD <br />❑ <br />Mechanical Line Leak Detector <br />Model <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />132' UI,I+CIV`StK,/11L7C'!S <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this Information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />WALTON <br />Signature: u� 01 ENGINEERING, INC. <br />Technician / Cert M Jessie Wadkins / B35391 5307886 -UT Date: April23, 2012 <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 5-6 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />■ <br />■ <br />❑ <br /># : 7-8 <br />Dispenser Containment Sensor(s) Model: 0794380-208 <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this Information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />WALTON <br />Signature: u� 01 ENGINEERING, INC. <br />Technician / Cert M Jessie Wadkins / B35391 5307886 -UT Date: April23, 2012 <br />