My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:37:32 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231130
PE
2361
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
01
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231130_3555 W HAMMER_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
479
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT ING SYSTEM CERTI ATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -360 <br />CERTIFICATION /TEST DATE: May 26, 2009 <br />Al. FACILITY A2. OWNER <br />Name Quik Stop Market #132 Nam* Quik Stop Markets, Inc. <br />Address 3555 W. Hammer Lane, Stockton, CA 95219 Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 Phone # 810-857-8500 <br />Contact Michael Karvelot Contact Michael Karvelot <br />A3. C U P A A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br />Address 600 E. Main Street, Stockton, CA 95202 Address P.O. Box 1023, W. Sacramento, CA 95691 <br />Notified May 18, 2009 Lic # 617238 A, B, Haz <br />Inspector Garrett Backus Contact Richard Walton <br />Phone # 209.468-3439 Phone # 918-825.3203 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (check the appropriate boxes to Indicate equipment inspect*dlservicsd) <br />131: TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline - 89 <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390409 <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390409 <br />■ <br />Piping Sump I Trench Sensor(s) <br />Model: 0784390-209 <br />■ <br />Piping Sump I Trench Sensors) <br />Model: 0794380-M <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensors) <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />■ <br />Mechanical Line Leak Detector <br />Model: VMI 98LD-2000 <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Lin* Leak Detector <br />Model: <br />❑ <br />Tank Overfill I High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill I High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Otte (specify equipment in Section E) <br />Model: <br />Tank #3 (Product): Gasoline - 91 <br />j` <br />Tank #4 (Product): _ <br />r <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />E <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0784380409 <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />■ <br />Piping Sump I Trench Sensor(s) <br />Model: 0794390-209 <br />❑ <br />Piping Sump I Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: FE Petro STP -MLD <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill I High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill I High -Level Sensor <br />Model: <br />❑ <br />other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />B2: DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794390-2W <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />■ Dispenser Containment Sensor(s) Model: 0794390-208 <br />■ Shear Valves <br />❑ Dispenser Containment Floats) and Chains) <br />Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Show Valves <br />❑ Dispenser Containment Float(s) and Chaln(s) <br />Dispenser # : 3.4 <br />■ Dispenser Containment Sensors) Model: 0794380-209 <br />■ Shear Valves <br />❑ Dispenser Containment Ftoags) and Chain(s) <br />Dispenser # : 7-8 <br />■ Dispenser Containment Sensor(s) <br />■ Shear Valves <br />❑ Dispenser Containment Floats) and <br />Dispenser # <br />❑ Dispenser Containment Sensor(s) <br />❑ Shear Valves <br />❑ Disperser Containment Float(s) and <br />C. CERTIFICATION 1 ce ft that the equipmat identified in this document vas in accordance with the nwndaeauws' guireanes. <br />Attached to this CertiRcntlon is Information (e.g. manufactures' checkihft) necessary to verity that this information is correct and a Plot Pian showig the <br />layout of monitoring equipment. For any equipment capable of generating such reports, l have also attached a copy of the report, (chock as that apply): <br />■ system set7vp ■ Alarm History Report <br />Signature: � ' . W,0= <br />WLLTOII <br />ENGINEERING, INC. <br />Technician I Cert #: Jessie YWdldn s 1836391 53076864JT Date: May 26, 2W9 <br />
The URL can be used to link to this page