My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
515
>
2300 - Underground Storage Tank Program
>
PR0231400
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
4/27/2020 12:24:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231400
PE
2361
FACILITY_ID
FA0003539
FACILITY_NAME
S B GAS & MARKET
STREET_NUMBER
515
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23309031
CURRENT_STATUS
01
SITE_LOCATION
515 W ELEVENTH ST STE 301
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231400_515 W ELEVENTH_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FRQM : NO. : Jul. 0016 12:25PM P3 <br /> S p _ <br /> V � <br /> San Joaquin County <br /> Environmental Health Department 2016 <br /> 1868 East Hazelton Avenue, Stockton, Califomis 05205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web: ov.ot hd ; <br /> L her " <br /> NXI <br /> Facility Name: Facility Phone: Data: <br /> S B GAS&MAR 209 834-8838 July 15 2015 <br /> Facility Add CERS ID: <br /> 515 W ELEVENTH ST TRACY CA 95376 10181209 <br /> kts "on C Title: Rhona: <br /> Ken Cook Assistant Klan et (209)607-0484 <br /> Inspection'type Prr>"= <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For cons-ant Given By: <br /> 19 Ins ec#on ® Photos ®Samples I Ken Cook Assistant Mana et <br /> Service Technician Onsitc Exp.Date: DesignaW ops Exp.Data: <br /> Dave Winkler 03/03/2016 Karen Arnaiz 05/0512017 <br /> Service Teohniclan ManulacWraes Training <br /> Incon (level 4), 1,2/08116;VMI 11110/15; Tank Tester,03/31/15 <br /> =Caiiifamis ogulatians = Ith eros saretX CFR=code 1 aepoia <br /> v=Nictation R Repeat violation cos r Corrected on site wring inspection <br /> .. .. .. .. ..•,r:•f '3L.•, yy.:.l,,;a:ay:..'v,:.. ,�:.:.,t':.:'�1 .:,,".:,., .�, r�.,y'i:'1."r r:!7.:::..7:1'766b a S �S,• ,.. <br /> . ".,,1Y .ta-1:... Q..... .ln.,...,,. ..1 ....< .:.. ., ,, <br /> ...101 HSC ff <br /> MSC 25281 No permit to operate n V o R o COS <br /> 102 HSC 25284(x)(3) No written agreement between tank owner and tank operator to monitor the tank 5yi5tem o V u R u COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted r V A R n COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or Current n V u R o COS <br /> 105 HSC 25286(c) Current BOE number not submitted �.. n V o R u COS <br /> v •.105 CCR 2632 Monitoring and response plans not current or approved by the EHO ■V o R o COS <br /> 7 I CCR 2632(d)(1)(C) Plot planisite map not submitted or failed to completely show where monitoring is performed' ■V a R u COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the END 48 hours prior to conducting testing n V n R o COS <br /> 109 CCR 2637 Failed to test secondary Containment o V u R c COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V o R n COS <br /> 111 CCR 2638(x) Failed to test monitoring and leak detection equipment annually u V u R a COS <br /> 112 HSC 25284.2 Failed to test will containers annually n V n R a COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ■V n R n COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual Brie test for pressurized piping without fail safe or shut down n V r R o COS <br /> 115 CCR 2715(a) Failed to inform the E14D of a change of designated operator within 30 days c V o R u COS <br /> 116 CCR 2715 Designated operator,service tech or instalW did not possess current ICC certification n V o R o COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well OV UR u COS <br /> 118 HSC 25292,5 Failed to repair and retest system due to failed ELD test u V u R o COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days n V 'n R o COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10}rears of lining and every 5 years after a V alk u COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests u V u R u COS <br /> 122 HSC 25299 Documents were falsified or misrepresented u V u R u COS <br /> 123 CCR 2661 Permit to repair UST system not obtained o V o R o COS <br /> 124 CCR 2635(4) FailEsd to submit UST Certification of Installation/Modification u V u R ❑COS <br /> ivad by trrs Phone: Data: <br /> (Initlaq: CINDY VO. EH Specialist (209)468-8257 07/15/2015 <br /> Page 1 of B <br />
The URL can be used to link to this page
Your browser does not support the video tag.