Laserfiche WebLink
R ♦ x <br /> �.s <br /> U L L ET I N October 17, 2011 • TBO811-03 <br /> Dispensing <br /> Product Revision Differences <br /> The table below highlights differences between the legacy DC400 system and the current system. <br /> Legacy Release Current Release <br /> Geometric Form Factor Rectangular Circular <br /> Picture of the 404-4 , am <br /> Controller <br /> Adm <br /> Installation Instructions, 000-0312 000-0316 <br /> document part number <br /> Power Wiring 7 wires: 6 wires: <br /> -Black(line voltage) -Black(line voltage) <br /> -Blue(Neutral) -White(Neutral) <br /> -Green (Ground) -Green (Ground) <br /> -Orange(Line Voltage, Relay Out) -Orange(Line Voltage, Relay Out) <br /> -Orange/Black(Line Voltage, Relay in) -Orange/Black(Line Voltage, Relay in) <br /> - Red(Line Voltage) - Green (Safety Ground) <br /> -Yellow(Neutral) <br /> Power Conduit 1/2" Conduit 3/4" Conduit with mandatory EYS fitting <br /> Sensor Connectors and 4-Pin, 3-wire friction coupling 2-wire QuikOn connector to: <br /> Sensors connecting to either: -ULS, Non-Latching, Float Sensor(S404). <br /> -Latching Float Sensor(S404) <br /> -Non-Latching Optical Sensor(S406) <br /> Sensor Test Procedure -S404: Invert sensor and use supplied -S404: Invert sensor <br /> tool to reset it. <br /> -S406: Submerge and obscure light <br /> source. <br /> Installer and Service - Requires certification currently -Requires NEW certification obtained via <br /> Technician Certification obtained via Franklin Fueling Franklin Fueling Systems'TECHLAB <br /> Systems'TECHLAB portal: portal: http://techlab.franklinfueling.com <br /> http://techlab.franklinfueling.com <br />