My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002491
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NOWELL
>
26200
>
3500 - Local Oversight Program
>
PR0545614
>
ARCHIVED REPORTS_XR0002491
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2020 4:14:23 PM
Creation date
4/27/2020 3:49:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002491
RECORD_ID
PR0545614
PE
3528
FACILITY_ID
FA0009531
FACILITY_NAME
UFP Thornton LLC
STREET_NUMBER
26200
STREET_NAME
NOWELL
STREET_TYPE
Rd
City
Thornton
Zip
95686
CURRENT_STATUS
02
SITE_LOCATION
26200 Nowell Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCLUSIONS <br /> With the completion of the hand augered borings the lateral <br /> extent of the soil and ground water plumes resulting from the TVG <br /> tanks has been defined, (see Figures 4 and 5) Both plumes are <br /> confined to area close to the original tank pit Unfortunately, <br /> the forklift shop is also located close to the former tank pit <br /> and both the soil and ground water hydrocarbon plumes extend <br /> under the building The low levels (below detection limits) in <br /> HA3 and the presence of gasoline range hydrocarbons in HA2 <br /> indicate that the TPHg soil and ground water plumes extend at <br /> least 17 and not more than 28 feet under the shop Therefore, at <br /> least a quarter of the shop sits over the gasoline contaminate <br /> plume <br /> LIMITATIONS <br /> The services performed by RAH Environmental, Inc, a corporation, <br /> or their drilling subcontractor Western Geo -Engineers under <br /> California Registered Geologist #3037 and/or Contractors License <br /> #592216, is conducted in a manner consistent with the level of <br /> care and skill ordinarily exercised by members of our profession <br /> currently practicing under similar conditions in the State of <br /> California and San Joaquin County our work and/or supervision <br /> of remediation and/or abatement operations , active or preliminary <br /> at this site is no way meant to imply that we are owners or <br />. operators of this site Please note that the known contamination <br /> of soil and/or ground water must be reported to the appropriate <br /> agencies in a timely manner No other warranty expressed or <br /> implied, .is made <br /> If you have any questions concerning this work plan, or if we can <br /> be of further assistance, please do not hesitate to contact us at <br /> (916) 652-5 77 7 <br /> 4L <br /> Jack Napp Roy Butler Ra enry <br /> R G # 3037 N EDcle Ieologist Project Mnager <br /> JACK E <br /> !NAPPER <br /> Na 3037 <br /> OF C�.�F� <br /> 5 <br />