Laserfiche WebLink
u <br /> HUNTER ENVIRONMENTAL SERVICES, INC. - FINAL TEST RESULTS <br /> 18350 MT. LANGLEY STREET, SUITE 101 TEST DATE: 3/23/88 <br /> FOUNTAIN VALLEY, CA 92708 <br /> 800-247-9014 800-247-2186 <br /> CUSTOMER: ARCO LOCATION/IDENTIFICATION NO.: 6020 <br /> ADDRESS: 1711 E. YOSEMITE <br /> MANTECA, CA <br /> TEST RESULTS SUMMARY <br /> LEAK LOKATOR RESULTS <br /> --------------------------------------------------------- <br /> SYSTEM TANK SIZE WATER LEVEL ALR <br /> ----------------- <br /> NO. PRODUCT GALLONS DIA/MATL INCHES INCHES GPH CONCLUSION RECOMMENDATIONS <br /> ---------------------------------------------------------------------------------------------------------------- <br /> 1 S/U 8000 92/FG 0 167 -.029 TIGHT <br /> 2 U/L 12000 92/FG 0 151 +.031 TIGHT <br /> 3 REG 12000 92/FG 0 147 -.011 TIGHT <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> NO. PRODUCT REMOTE - --- <br /> SUCTION APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br /> ---------------------------- ------------------------------ -------------------------------------------------- <br /> 1 S/U RED JACKET 50 10 PASS <br /> 2 U/L RED JACKET 50 10 PASS <br /> 3 REG RED JACKET 50 10 PASS <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> TEST TIME LEAK RATE TEMPERATURE ABSOLUTE CHECK <br /> SYSTEM TEST LEVEL CLOCK DURATION COMPENSATION LEAK RATE TEST <br /> ND. PRODUCT NO. (IN.) STATE (HR-MIN) CC/DIV CC/MIN DELTA of CC/MIN CC/MIN GPH Y/N <br /> ' S/U 1 161 12:00 :32 +2.380 +2.857 +.011 +4.718 -1.861 -.029 <br /> 2 U/L 1 151 10:00 :28 +1.119 +18.470 +.033 +16.487 +1.982 +.031 <br /> 3 REG 1 147 11:15 :30 A1.327 +2.749 +.007 +3.481 -.731 -.001 <br /> *LEVEL - Inches from Tank. Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br /> CERTIFICATION <br /> CERfl'FIEV <br /> I � <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br /> established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br /> Tests Conducted and Certified By: Test Van No. 20 <br /> Team Manager: M. EHLERT <br /> Tank Testing Specialist: S. PORRAS <br />