My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005807
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
935
>
3500 - Local Oversight Program
>
PR0545617
>
ARCHIVED REPORTS_XR0005807
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2020 1:59:09 PM
Creation date
4/28/2020 1:13:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005807
RECORD_ID
PR0545617
PE
3528
FACILITY_ID
FA0005557
FACILITY_NAME
RIPON FARM SERVICE
STREET_NUMBER
935
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102007/2011
CURRENT_STATUS
02
SITE_LOCATION
935 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. 20 January 2000 <br /> AGE-NC Project No 95-0173 <br /> Page 2 of 14 <br /> approximately 20 feet below surface grade (bsg) <br /> • Total petroleum hydrocarbons quantified as gasoline (TPH-g) were detected in ten soil <br /> samples at concentrations as high as 3,800 milligrams per kilogram(mg/kg) Total petroleum <br /> hydrocarbons quantified as diesel(TPH-d)were detected in twelve samples at concentrations <br /> as high as 9,000 mg/kg The maximum concentration of TPH-g was detected in sample B4- <br /> 20, the maximum TPH-d was detected in sample 138-20 <br /> • TPH-g was detected in ground water samples from MW-1, MW-2 and MW-3 at <br /> concentrations of 1,700 micrograms per liter(µg/1), 14,000µg/1 and 2,600µg/1,respectively <br /> TPH-d was detected in the MW-1, MW-2 and MW-3 samples at concentrations of 2,400 <br /> µg/1, 9,200µg/1 and 6,900 µg/I, respectively <br /> With the exception of one sample(134-20),concentrations of TPH-d exceed concentrations of TPI -g <br /> in the soil samples Analytical results of soil samples are included in Table 1 Analytical results of <br /> ground water well samples are included in Table 2 <br /> . In August 1995, five additional soil borings(B9 through B13) were drilled at the site Two borings <br /> were completed as ground water monitoring wells west and south of the previous three wells (MW-4 <br /> and MW-5) During drilling, ground water was encountered at a depth of approximately 20 feet bsg <br /> • TPH-g was detected in four soil samples at concentrations as high as 23 mg/kg TPH-d was <br /> detected in six soil samples at concentrations as high as 1,900 mg/kg Volatile aromatic <br /> hydrocarbons (benzene, toluene, ethyl benzene BTEX) were not detected in any of the soil <br /> samples analyzed <br /> • One grab ground water sample was collected from boring B13 located northeast of the <br /> former USTs Both TPH-g and TPH-d were detected in the grab water sample at <br /> concentrations of 6,500 4g/1 and 450,000 4g/l, respectively BTEX compounds were not <br /> detected in these samples Analytical results of grab water samples are included in Table 4 <br /> With the exception of sample ASB13/10, the concentrations of TPH-d significantly exceeded <br /> concentrations of TPH-g in the soil samples analyzed Sample ASB13/10 contained 10 mg/kg TPH- <br /> g and less than detectable concentrations of TPH-d „ <br /> In October 1996, three soil probe borings (B14 through B16) were advanced on the Jimco Truck <br /> Stop located immediately north of the site and one boring was advanced on the site (B 17) During <br /> drilling, ground water was encountered at a depth of approximately 20 feet bsg <br /> !) Adpanced GeoEnvironmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.