Laserfiche WebLink
' TABLE 1 <br /> GROUNDWATER TREATMENT SYSTEM FLOW DATA <br /> Speedy Foods <br /> 6 $200 N Hwy 99, Stockton, California <br />' (Page 2 of 4) <br /> Meter Period Cumulative Measured Period <br />' Date Reading Flow Flow Flow Rate Flow Rate Comments <br /> (gallons) (gallons) (gallons) (gpm) (mgd) <br />' 04/26/04 254319 13233 254319 1 0 1 1 E-3 System down restarted system then sampled C1, C2, EFF <br /> 05/03/04 263156 8837 263156 09 1 3 E-3 System running, sampled C1, C2 EFF <br /> 05/10/04 269786 6630 269786 09 9 5 E-4 INF C1, C2, EFF samples collected <br /> 05/17/04 278660 8874 278660 1 0 1 3 E-3 System running,sampled C1, EFF <br />' 05/24/04 287670 9010 287670 1 0 1 3 E-3 System running,sampled C1, EFF <br /> 06/01/04 297011 9341 297011 09 1 2 E-3 System running sampled C1 EFF <br /> 06/07/04 303990 6979 303990 09 1 2 E-3 System running sampled C1, EFF <br />' 06/14/04 311780 7790 311780 09 1 1 E-3 System running, sampled INF, C1 EFF <br /> 06/21/04 319068 7288 319068 08 1 0 E-3 System running,sampled C1 EFF <br /> 06/23/04 321064 1996 321064 08 1 0 E-3 System running, monitored while on site for quarterly well <br />' sampling <br /> 06/28/04 325862 4798 325862 08 1 0 E-3 System running sampled C1, EFF <br /> 07/06/04 333228 7366 333228 08 9 0 E-4 System running sampled C1 EFF <br /> 07/16/04 340018 6790 340018 07 6 0 E-4 System running sampled INF C1 EFF <br />' 07/26/04 346027 6009 346027 - 6 0 E-4 System down unable to restart system <br /> 07/30/04 346027 0 346027 _ - Completed installation of air stripper order subpanel to integrate <br /> auto shut-off tie-in to extraction pump <br /> Troubleshoot extraction pump, remove and clean down-well level <br /> 08/13/04 346027 0 346027 _ - probes test system water level in well too low to effectively use <br /> down-well probes, order installation of pump-tech controller, meter <br /> at 346086 <br /> 08/23/04 346086 59 346086 - Modify system to install auto interlocks,test system and operate <br /> short period Meter at 346435 when test complete <br /> 08/24/04 346435 349 346435 _ - System startup Initial flow at 4 3 gpm, flow meter failed at <br /> - 346453 System shut down to repair/replace flow meter <br /> 08/26/04 346453 18 346453 - Installed and tested replacement flow meter Initial meter reading <br /> 1985 <br /> 08/27/04 1985 125 346578 _ - System startup Initial flow at 3 3 gpm at 9 13am Flow at <br /> 10 03am is 2 6 gpm flow meter reading at 2110 <br /> System running at 2 00pm, but flow meter faded at 2322 System <br /> 08/27/04 2322 717 347295 20 - off at 2 45pm Based on flow rate(2 0-2 6 gpm)estimate meter <br /> failure at 11 35am, estimated volume treated after meter failure <br /> (2gpm)is 380 gallons <br /> Cleaned and flushed flow meter and re-installed and tested meter <br /> 08/30/04 2322 100 347395 - - Meter failed again(2396) after pumping for 35 minutes at 2 1-3 4 <br /> gpm(--100 gallons) System shut down to replace meter <br /> Cleaned and flushed flow meter and installed in effluent stream <br /> 08/31/04 2396 0 347395 - - after carbon units Re-start system at 6 18pm and test meter <br /> I Meter okay,system left pumping <br /> 09/01/04 4021 1625 349020 1 6 System running Sampled INF,ASI, C1, and EFF Installed new <br /> meter on influent line effluent meter still operating <br /> System down INF meter 563, EFF meter 4654 Re-started and <br /> 09/03/04 4654 633 349653 - - monitored system System and meters appear to be operating <br /> fine <br /> System running INF meter 4076, EFF meter 7903 Lowflowfrorr <br /> 9107104 7903 3249 352902 - 81 E-4 extraction well Changed water filter and flow increased to 2 9 <br /> gpm <br />