Laserfiche WebLink
' TABLE 3 <br /> GROUNDWATER TREATMENT SYSTEM FLOW DATA <br /> 1 Speedy Foods <br /> 8200 N Hwy 99, Stockton, California <br /> Meter Period Measured Period <br /> Date Reading Flow Flow Rate Flow Rate Comments <br /> (gallons) (gallons) (gpm) (mgd) <br /> 11/05/03 0 0 1 9 0 System Startup <br /> 11/05/03 620 620 20 2 7 E-3 INF,C1, EFF samples collected <br />' 11/06/03 2487 1867 17 1 9 E-3 <br /> 11/07/03 2620 133 0 1 3 E-4 System down due to switch malfunction <br /> 11/10/03 4220 1600 1 5 5 3 E-4 INF, C1, EFF samples collected <br />' 11/11/03 6602 2382 1 5 2 4 E-3 <br /> 11/12/03 8315 1713 14 1 7 E-3 <br /> 11/13/03 9510 1195 1 7 1 2 E-3 <br />' 11/14/03 12111 2601 1 8 2 6 E3 <br /> 11/17/03 18445 6334 1 5 2 1 E-3 INF, C1, EFF samples collected <br /> 11/18/03 21685 3240 1 3 32 E-3 System shut down for carbon change <br /> 11/21/03 21685 0 0 0 Pump removed and skimmer installed in extraction well <br /> 12/01/03 21685 0 0 0 Carbon replaced <br /> 12/03/03 21685 0 0 0 Skimmer removed and pump replaced in extraction well <br /> 12/04/03 21685 0 0 1 0 Carbon wetted and system pressure tested(gaskets ordered) <br /> 12/10/03 21871 186 0 0 Gaskets changed and system pressure tested <br /> 12/11/03 22425 554 1 9 0 System re-started and samples collected from C1,C2, EFF <br /> 12/12/03 24947 2522 20 2 5 E-3 <br />' 115/03 33090 8143 1 8 2 7 E-3 INF,C1,C2, EFF samples collected <br /> 2116103 35939 2849 165 2 8 E-3 <br /> 12/18/03 40246 4307 14 2 2 E-3 C1 C2, EFF samples collected, replaced water filter <br /> 12/22/03 49218 8972 14 22 E-3 INF, C1, C2, EFF samples collected <br />' 12/26/03 55955 1 6737 12 1 7 E-3 C1, C2, EFF samples collected <br /> 12/30/03 62250 6295 1 35 16 E-3 JINIF,C1,C2 EFF samples collected, replaced water filter <br />' Notes <br /> gpm gallons per minute <br /> gpd = gallons per day <br /> 1 <br /> 1 <br /> 1 <br />