Laserfiche WebLink
Table 3-3 <br /> Containers with Potential for Oil Dischar e <br /> Area Type of Potential Direction of Secondary Secondary <br /> failure Discharge Flow for Containment Containment <br /> (discharge Volume Uncontrolled method Capacity <br /> scenario) (Gals) Discharge (Gals) <br /> Containers' <br /> Yard–Unleaded Premium Container 12,000 Pools in Bermed Total @ <br /> Gasoline-91/Diesel AST#1 Rupture,• (largest enclosure Secondary 5,000gals. <br /> Leak Overfill chamber in Containment <br /> AST) <br /> Yard–Unleaded Regular Container 250 gals Pools in Integral Total @ <br /> Gasoline-87 AST#2,#3,#4 Rupture, each enclosure Secondary 100% @ 750 <br /> Leak Overfill Containment gals. <br /> Piping, Valves, etc. <br /> N/A <br /> Additional Areas location where oil is loaded to or from a container <br /> Service Bay–New Oil/15w40 Container 300 Pools in Berm Total Tanker <br /> Rupture, enclosure Contents 300 <br /> Leak gals. <br /> Overfill <br /> Service Bay-ATF Container 120 Pools in Integral Total Tanker <br /> Rupture, enclosure Secondary Contents <br /> Leak Containment 9,500gals. <br /> Overfill <br /> Other Oil-Handling Areas or Oil-Filled Equipment(e.g.flow-through process vessels at an oil production facility)— <br /> Service-Bay(DEF) I Container Rupture 1300 1 Pools in Bay I None 1300 gals <br /> a Use one of the following methods of secondary containment or its equivalent: (1) Dikes, berms, or retaining walls <br /> sufficiently impervious to contain oil; (2)Curbing; (3) Culverting, gutters,or other drainage systems; (4)Weirs, booms, or <br /> other barriers; (5) Spill diversion ponds; (6) Retention ponds;or(7) Sorbent materials. <br /> b For storage tanks and bulk storage containers,the secondary containment capacity must be at least the capacity of the <br /> largest container plus additional capacity to contain rainfall or other precipitation. <br /> If a catastrophic event, such as an earthquake or major fracture occurred, 13,470 gals. <br /> (capacity of all vessels) could be lost*. <br /> Facility has seven storage tanks. Tanks are: a) AST 10 12,000 gals Diesel fuel* b,c,d) <br /> are 250-gal ConVault tanks w/ gasoline, waste oil, and kerosene respectively. All <br /> tanks have integral secondary containment- the ASTs are situated @ the south of the <br /> Service-Bay. In the Service Bay are: 1) 300-gallon new oil tank within a poly-berm; 2) <br /> 120-gallon ATF tank with integral/metallic secondary containment AND 3) a 300-gallon <br /> poly DEF tank with NO secondary containment. <br /> Additionally there is inventory of various lubricants, in small (less than 55 gal.) <br /> containers in the Maintenance location the inventory of such changes from time to time <br /> based on usage. <br /> *USTs are exempt from SPCC plan guidelines but are referenced herein. <br /> 22 <br />