Laserfiche WebLink
T & T Trucking page 2 <br /> 11396 Hwy 99 Frontage N, Lodi <br /> Work Plan Comment <br /> EHD approves pilot testing for the ART pilot test with the following conditions: <br /> 1. a test of all constituents of the ART system is to be conducted, to include the <br /> DPE components discussed in the Pian and addendum, (GWElcirculation + <br /> SVE and IAS) and, <br /> 2. a constant soil vapor extraction is to be applied in VEW-1 at all times <br /> following it's installation until the risk of MtBE vapor causing additional impact <br /> to the ground water has been shown to be reduced to negligible levels. EHD <br /> cannot allow the soil vapors containing elevated levels of contaminantion in <br /> the vadose and upper level of the proposed VEW-1 to intermingle with the <br /> ground water in the lower screened interval of VEW-1. Constant SVE in <br /> VEW-1 should minimize the potential for residual MtBE in the vadose to <br /> become dissolved in the already highly MtBE impacted ground water. <br /> As ART technology has not been used in San Joaquin County, EHD has discussed <br /> the proposal with the State Water Resources Control Board (SWRCB) Clean Up <br /> Fund (CUF) technical staff to determine if the costs for this technology will be <br /> reimbursed. EHD recommends you contact the SWRCB for reimbursement <br /> preapproval for this work prior to finalizing your proposed work. <br /> UST regulations allow for interim remedial action to be conducted concurrently with <br /> the investigative phase. B&C has concluded that the vertical extent of the <br /> contaminant plume has not been established and EHD has concerns that a full <br /> understanding of the contaminated soil mass and migration pathways has not been <br /> demonstrated. EHD will require additional investigation be conducted at the site to <br /> address these concerns in the very near future. A full remedial action plan cannot <br /> be approved until the nature and extent and lateral and vertical limits of the plume <br /> are defined. <br /> You may contact Mr. Infurna if you have any questions or wish to discuss the site. <br /> You may call Mr. Infurna at (209) 468-3454 or email him at minfurna a@sicehd.com. <br /> Donna Heran, REHS, Director <br /> Environm;Infurna <br /> l Healt Dep rtment <br /> ichael JJr., Senior REHS Margare Lagorio, R S <br /> LOP 1 Site Mitigation Unit IV Supervisor <br /> MI/ <br /> c: CVRWQCB — J.L. Barton, Sacramento. <br /> c: SWRCB--CUF — Mark Owens, Sacramento. <br /> c: Brown & Caldwell - Tina Bauer 2701 Prospect Park Dr., Rancho Cordova. <br />