| APEX ENVIROTECH„ INC.
<br />       	STANDARD OPERATING PROCEDURES
<br />       	Quarterly Monitoring Reports
<br />'    	SOP - 4     							When practical,the groundwater sample should be coliected
<br />       	SAMPLE IDENTIFICATION AND CHAIN-   	when the water level In the well recovers to at least 80 percent
<br />       	OF-CUSTODY PROCEDURES   			of its static level
<br /> 											The sampling equipment consists of either a"Teflon"bailer,
<br />       	Sample identification and chain-of-custody procedures ensure    	PVC bailer,or stainless steel bladder pump with a"Teflon"
<br />       	sample Integrity as well as document sample possession from    	bladder  If the sampling system is dedicated to the well,then
<br />       	the time of collodion to ultimate disposal  Each sample  		the bailer is usually"Teflon,"but the bladder pump is PVC with
<br />       	container submitted for analysis is labeled to identify the job      	a polypropylene bladder In general and depending on the
<br />       	number,date,time of sample collection,a sample number		intended laboratory analysis,44milldQer glass,volatile organic
<br />       	unique to the sample,any in-field measurements made,   		analysis(VOA)vials,with'Teflon"septa,are used as sample
<br />       	sampling methodology,name(s)of on-site personnel,and any    	containers
<br />       	other pertinent field observations also recorded on the field
<br />       	excavation or boring log  						SOP - 12
<br />  											MEASURING LIQUID LEVELS USING
<br /> '    	Cham-of-custody forms are used to record possession of		WATER LEVEL METER OR INTERFACE
<br />       	thesample from time of collection to a"at the laboratory       	PROBE
<br />		During shipment,the person with custody of the samples will
<br />		relinquish them to the next person by signing the chain-of-		Field equipment used for liquid-level gauging typically Includes
<br /> '    	custody form(s)and noting the date and time The sample-      	the measuring Instrument(water4evel meter or Interface probe)
<br />		control officer at the laboratory will verify sample integrity, 		and product bailer(s) The field lat also includes cleaning
<br />		correct preservation,confirm collection In the proper      		supplies(buckets,solution,spray bottles,and deionmed water)
<br />		container(s),and ensure adequate volume for analysts    		to be used in cleaning the equipment between wells
<br /> '    	If these conditions are met,the samples will be assigned 		Prior to measurement,the instrument tip is lowered into the well
<br />		unique laboratory log numbers for Identification throughout		until it touches bottom  Using the previously established top-of-
<br />		analysis and reporting The log numbers will be recorded on     	casing or to"f-box(i e,wellhead vault)point,the probe cord
<br />       	the chain-o-custody forms and in the legally-required log book    	(or halyard)is marked and a measuring tape(graduated in
<br />		maintained in the laboratory The sample description date       	hundredths of a foot)is used to determine the distance
<br />		received,client's name,and any other relevant information will    	between the probe end and the marking on the cord This
<br />		also be recorded 							measurement is then recorded on the liquid-level data sheet as
<br />  											the"Measured Total Depth"of the well
<br />  											When necessary In using the Interface probe to measure liquid
<br />		LABORATORY ANALYTICAL QUALITY      	levels,the probe is first electrically grounded to either the metal
<br />		ASSURANCE AND CONTROL   			stove pipe or another metal object nearby When no ground is
<br /> t      										available,reproducible measurements can be obtained by
<br />		In addition to routine instrument calibration replicates,spikes,    	clipping the ground lead to the handle of the Interface probe
<br />		blanks spiked blanks,and certified reference materials are       	case
<br />		routinely analyzed at method-specific frequencies to monitor      	The probe tip is then lowered into the well and submerged in
<br />		precision and bias Additional components of the laboratory      	the groundwater An oscillating(beeping)tone indicates the
<br />		Quality AssurancelAualRy Control program include       		probe is in water The probe Is slowly raised until either the
<br />		1 	Participation In state and federal laboratory     		oscillating tone ceases or becomes a steady tone  In elther
<br />  			accreditation/certification programs    			case,this is the depth-to-water(DTW)indication and the DTW
<br /> '       										measurement is made accordingly The steady tone indicates
<br />		2	Participation in both U S EPA Performance    		floating liquid hydrocarbons(FLH)  In this case,the probe is
<br />   			Evaluation studies(WS and WP studies)and inter-    	slowly raised until the steady tone ceases This is the depth-to-
<br />  			laboratory performance evaluation programs,   		product(DTP)indication and the DTP measurement is made
<br />'       										accordingly
<br />		3 	Standard operating procedures describing routine     	The process of lowering and raising the probe must be
<br />  			and periodic instrument maintenance,  			repeated several times to ensure accurate measurements The
<br />		4 	"Out-0f-Control'/Corrective Action documentation      	DTW and DTP measurements are recorded on the liquid-level
<br />'       		procedures,and,      					data sheet When FLH are Indicated by the probe's response,
<br />  											a product bailer is lowered partially through the FLH-water
<br />		5 	Mufti-level review of raw data and chert reports 		Interface to confirm the FLH on the water surface and as
<br />  											further indication of the FLH thickness,particularly in cases
<br />'    	SOP - 7     							where the FLH layer Is quite thin This measurement is
<br />		GROUNDWATER PURGING AND      		recorded on the date sheet as"FLH thickness"
<br />  iie       SAMPLING							In order to avoid cross-corrtaminstion of wells during the liquid-
<br />		Prior to water sampling,each well is purged by evacuating a      	level measurement process,wells are measured in the order of
<br />		minimum of three wetted well-casing volumes of groundwater     	"'clean"to"dirty'(where such Information Is available)  In
<br />		When required,purging will continue until either the      		addition,all measurement equipment Is cleaned with solution
<br />		dischargethree wetted well-casing volumes of groundwater       	and thoroughly rinsed with delonized water before use,between
<br />		When required,purging will continue until either the discharge    	measurements In respective walls,and at the completion of the
<br />'     	water temperature,oonductivity,or pH stabilize,a maximum of    	days use
<br />		ten wetted-casing volumes of groundwater have been
<br />		recovered or the well Is bailed dry
<br /> |