Laserfiche WebLink
CONDITIONS FOR N-2682-I-0 page; 2 <br /> ,0S. Measurements to determine the influent and the effluent gas flow rates shall be taken at the initial <br /> ;nspection. Flow rate calculanons shall be submitted to the District along with the laboratory sample <br /> clysis results. <br /> 9. Initial compliance with VOC emission rate and control efficiency requirements shall be demonstratcdby <br /> the results of the laboratory sample analysis. The results shall be submitted to the District within <br /> 60 days of the test. <br /> 10. Ongoing compliance with VOC emission rate and contral, efficiency requirements shall be demonstrabedby <br /> sampling both the influent and effluent gas streams with an FID, PID, or other District-approved-VOC <br /> detection device. <br /> 11. Sampling to demonstrate ongoing compliance shall be performed at least once per week. <br /> 12. Records of the cumulative running time and the measured influent and effluent VOC concenuationcobalL. <br /> be maintained. <br /> 13. All records shall be retained for a minimum of 2 years, and.shall be maddavailable for District <br /> inspection upon request. <br /> 14. The total NOx emission-rate from-the soil remediation system-served-by the internal combustiat <br /> shall not exceed 0.5 lb/h%Mtu. <br /> 15. The total CO emission rate from the soil remediation system smmul by the-internal,combustion-m o[� <br /> shall not exceed 5.1 lblMNMtu. y-r, 11 �„ <br /> 16. The total VOC emission rate from the soil remediation system served by the intcmal combustioat:m�oe`. <br /> shall not exceed 8.1 pounds in any one day. <br /> �7 Flther the VOC control efficiency shall not be less than 95 0, or the total VOC emission rate shall ttoit. e.e <br /> pounds in any one day. <br /> 18. Operation of the soil remediation system shall not exceed 3 years without prior District approval— <br />