PLUMBING PLUMBING
<br /> SECTION 221316-SANITARY WASTE AND VENT PIPING SECTION 221319-SANITARY WASTE PIPING SPECIALTIES
<br /> 1.1 PROJECT CONDITIONS 1.1 ACTION SUBMITTALS �•
<br /> A. INTERRUPTION OF EXISTING SANITARY WASTE SERVICE: DO NOT INTERRUPT A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE RATED
<br /> SERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTED CAPACITIES, OPERATING CHARACTERISTICS,AND ACCESSORIES FOR THE
<br /> UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO FOLLOWING:
<br /> PROVIDE TEMPORARY SERVICE ACCORDING TO REQUIREMENTS INDICATED: 1. FOG DISPOSAL SYSTEMS.
<br /> 1. NOTIFY CONSTRUCTION MANAGER NO FEWER THAN TWO DAYS IN ADVANCE OF 2. GREASE INTERCEPTORS.
<br /> PROPOSED INTERRUPTION OF SANITARY WASTE SERVICE. 3. GREASE REMOVAL DEVICES.
<br /> 2. DO NOT PROCEED WITH INTERRUPTION OF SANITARY WASTE SERVICE WITHOUT 4. WIRING DIAGRAMS: POWER, SIGNAL,AND CONTROL WIRING.
<br /> CONSTRUCTION MANAGER'S WRITTEN PERMISSION.
<br /> 1.2 QUALITY ASSURANCE ©2011 STARBUCKS COFFEE COMPANY
<br /> 1.2 MATERIALS A. QUALITY STANDARD FOR BELOW GRADE PLASTIC PIPING: NSF 14.
<br /> A. HUB-AND-SPIGOT, SERVICE-CLASS, CAST-IRON SOIL PIPE AND FITTINGS BELOW
<br /> GRADE WHERE REQUIRED BY LOCAL CODE. 1.3 PRODUCTS STARBUCKS COFFEE
<br /> B. HUBLESS, CAST-IRON SOIL PIPE AND CISPI, CAST-IRON OR HUBLESS PIPING A. BACKWATER VALVES: HORIZONTAL-CAST IRON, DRAIN OUTLET OR HORIZONTAL-
<br /> COUPLINGS. PLASTIC COMPANY
<br /> C. SOLID-WALL ORCELLULAR-CORE SCHEDULE 40 ABS PIPE WITH ABS SOCKET B. CLEANOUTS: 2401 UTAH AVENUE SOUTH
<br /> FITTINGS MAY BE USED ABOVE AND BELOW GRADE IF ALLOWED BY LOCAL CODE. 1. EXPOSED: COUNTERSUNK, COUNTERSUNK OR RAISED-HEAD, RAISED-HEAD,
<br /> D. SHIELDED, NONPRESSURE OR PRESSURE BRASS,CAST-IRON OR PLASTIC CLOSURE PLUG. SEATTLE, WASHINGTON 98134
<br /> TRANSITION COUPLINGS. 2. CERAMIC TILE AND CARPETED FLOORS: SQUARE,ADJUSTABLE WITH NICKEL (206) 318-1575
<br /> E. UNION, FLANGE, FLANGE INSULATING KIT OR NIPPLE DIELECTRIC FITTINGS. BRONZE TOP.
<br /> F. PE-FILM ENCASEMENT FOR UNDERGROUND METAL PIPING. 3. RESILIENT(VINYL)FLOOR: SQUARE,ADJUSTABLE, NICKEL BRONZE TOP WITH THESE DRAWINGS AND SPECIFICATIONS ARE
<br /> G. SCHEDULE 40 PVC PIPE WITH PVC SOCKET FITTING MAY BE USED BELOW GRADE COMPATIBLE FLANGE. CONFIDENTIAL AND SHALL REMAIN THE SOLE
<br /> IF ALLOWED BY LOCAL AUTHORITY. 4. WALL: ROUND, DEEP-CHROME-PLATED BRONZE,FLAT, CHROME-PLATED PROPERTY OF STARBUCKS CORPORATION,
<br /> BRASS OR STAINLESS-STEEL COVER PLATE WITH ROUND, CHROME PLATED, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS
<br /> 1.3 ADHESIVES SCREW WALL ACCESS. WORK. THEY SHALL NOT BE REPRODUCED(IN
<br /> A. ADHESIVES SHALL NOT EXCEED A VOC CONTENT OF 51OG/L FOR PVC AND 325 C. FLOOR DRAINS: WHOLE OR IN PART),SHARED WITH THIRD
<br /> G/L FOR ABS. 1. CAST-IRON FLOOR DRAINS, WITH STRAINER, BODY STYLE AND OPTIONS AS PARTIES OR USED IN ANY MANNER ON OTHER
<br /> SPECIFIED IN PLUMBING SCHEDULE. PROJECTS OR EXTENSIONS TO THIS PROJECT
<br /> END OF SECTION 221316 2. PROVIDE TRAP PRIMER CONNECTIONS WHERE NEEDED PER CODE AND DESIGN WITHOUT THE PRIOR WRITTEN CONSENT OF
<br /> REQUIREMENTS. STARBUCKS CORPORATION. THESE DRAWINGS
<br /> D. TRENCH DRAINS TO BE AS SPECIFIED IN PLUMBING SCHEDULE. AND SPECIFICATIONS ARE INTENDED TO EXPRESS
<br /> E. THROUGH-PENETRATION FIRESTOP ASSEMBLIES: LISTED AND LABELED ASSEMBLY DESIGN INTENT FOR A PROTOTYPICAL
<br /> OF SLEEVE AND STACK FITTING WITH FIRESTOPPING PLUG;WITH SPECIAL STARBUCKS STORE(WHICH IS SUBJECT TO
<br /> CORROSION-RESISTANT COATING ON INTERIOR OF FITTINGS. CHANGE AT ANYTIME)AND DO NOT REFLECT
<br /> F. MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES: ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL
<br /> 1. OPEN DRAINS, SHOP OR FIELD FABRICATE FROM SERVICE CLASS, HAVE ANY OBLIGATION NOR LIABILITY TO THE
<br /> HUB-AND-SPIGOT, CAST-IRON, SOIL-PIPE FITTINGS. OTHER(EXCEPT STATED ABOVE)UNTIL A
<br /> 2. CAST-IRON OR BRONZE DEEP-SEAL TRAPS. WRITTEN AGREEMENT IS FULLY EXECUTED BY
<br /> BOTH PARTIES.
<br /> 3. FLOOR-DRAIN,TRAP-SEAL PRIMER FITTINGS.
<br /> 4. AIR-GAP FITTINGS.
<br /> 5. COUNTERFLASHING-TYPE, CAST-IRON STACK FLASHING FITTINGS. ARCHITECT OF RECORD
<br /> 6. CAST-IRON BODY VENT CAPS. 0 -0 t
<br /> 7. FROST-RESISTANT VENT TERMINALS. o Eg == s.
<br /> 8. EXPANSION JOINTS. a � o
<br /> r
<br /> UZ U
<br /> 1.4 MANUFACTURED UNITS U,
<br /> A. FOG DISPOSAL SYSTEMS AS SPECIFIED IN PLUMBING SCHEDULE.
<br /> B. GREASE INTERCEPTORS AS SPECIFIED IN PLUMBING SCHEDULE. 4
<br /> C. GREASE REMOVAL DEVICES AS SPECIFIED IN PLUMBING SCHEDULE. mcg a r c h i t e c u r e
<br /> D. SOLIDS INTERCEPTORS: FACTORY-FABRICATED INTERCEPTOR MADE FOR
<br /> REMOVING AND RETAINING LINT OR SEDIMENT FROM 111 Pacifica,Suite 280,Irvine,CA 92618
<br /> WASTEWATER AS SPECIFIED IN PLUMBING SCHEDULE. P:949.553.1117 F:949.474.7056
<br /> END OF SECTION 221319
<br /> ACIES :OQRaFE.....•
<br /> :. PN G.R f le;'
<br /> PLUMBING ENGINEERING �o� ��':
<br /> 3371 Olcott Street z
<br /> SECTION 223000-DOMESTIC-WATER HEATERS Santa Clara,CA 95054 No. 4 ;
<br /> 1.1 QUALITY ASSURANCE ph:(408)522-5255 fin �c
<br /> fx:(408)522-5260 •:sT QFC Gp �Q:•
<br /> A. PERFORMANCE EFFICIENCY:ASHRAE/IESNA 90.1 AND ASHRAE 90.2. info@acies.net •• ql HAND
<br /> B. ASME COMPLIANCE:ASME BOILER AND PRESSURE VESSEL CODE: SECTION VIII, Copyright©2019 ••' ..•
<br /> DIVISION 1. •••••
<br /> C. NSF COMPLIANCE: NSF 61 ANNEX G, "DRINKING WATER SYSTEM COMPONENTS-
<br /> HEALTH EFFECTS."
<br /> 1.2 COMMERCIAL, ELECTRIC, DOMESTIC-WATER HEATERS
<br /> A. COMMERCIAL, LIGHT-DUTY, STORAGE, ELECTRIC, DOMESTIC-WATER HEATERS:
<br /> STEEL, GLASS LINED,VERTICAL ARRANGEMENT WITH 150-PSIG(1035-KPA)
<br /> PRESSURE RATING.
<br /> B. SEE PLUMBING SCHEDULE FOR MAKE, MODEL, CAPACITY, AND RECOVERY RATE.
<br /> 1.3 COMMERCIAL, GAS-FIRED, STORAGE, DOMESTIC-WATER HEATERS
<br /> A. COMMERCIAL,ATMOSPHERIC], POWER-BURNER OR POWER-VENT, GAS-FIRED,
<br /> STORAGE, DOMESTIC-WATER HEATERS: STEEL, GLASS LINED, VERTICAL
<br /> ARRANGEMENT WITH 150-PSIG(1035-KPA)PRESSURE RATING CONDENSING TYPE. O
<br /> MINIMUM EFFICIENCY 90%. MEETS LOW NOx EMMISIONS PER CODE
<br /> REQUIREMENTS. �JJ
<br /> ' ) N
<br /> 1.4 DOMESTIC-WATER HEATER ACCESSORIES L0
<br /> I
<br /> A. DRAIN PANS: CORROSION-RESISTANT METAL WITH RAISED EDGE. LLI
<br /> B. PIPING-TYPE HEAT TRAPS. 3: z Q
<br /> C. HEAT-TRAP FITTINGS. Q U
<br /> D. GAS SHUTOFF VALVES. w _I
<br /> E. GAS PRESSURE REGULATORS: PRESSURE RATING TO MATCH GAS SUPPLY
<br /> F. AUTOMATIC GAS VALVES. W z
<br /> G. PRESSURE-REDUCING VALVES. 2i
<br /> (/)w
<br /> H. COMBINATION TEMPERATURE-AND-PRESSURE RELIEF VALVES. Z Q
<br /> I. PRESSURE RELIEF VALVES.
<br /> J. VACUUM RELIEF VALVES. l_ V
<br /> K. SHOCK ABSORBERS. w N LU O
<br /> L. DOMESTIC-WATER HEATER STANDS.
<br /> M. DOMESTIC-WATER HEATER MOUNTING BRACKETS. O O
<br /> N. EXPANSION TANK 0 S � C)
<br /> 1.5 ALL COMPONENTS OF DOMESTIC WATER SYSTEM TOUCHING DOMESTIC WATER ARE G
<br /> LEAD FREE, INCLUDING ALL VALVES AND FITTINGS. STORE #: 13402
<br /> END OF SECTION 223000 PROJECT #: 39714-051
<br /> CASEWORK CONCEPT: CORE
<br /> ISSUE DATE:
<br /> PROGRAM MANAGER: M. DREBIKA
<br /> STORE DESIGNER: S. BELVINS
<br /> LEED®AP: N/A
<br /> CHECKED BY:
<br /> ACIES PROJECT#: 190480
<br /> ACIES DESIGNER BY: LL
<br /> ACIES CHECKED BY: MP
<br /> Revision Schedule
<br /> Rev Date By Description
<br /> SHEET TITLE:
<br /> PLUMBING OUTLINE
<br /> SPECIFICATIONS
<br /> SCALE:AS SHOWN N.T.S.
<br /> SHEET NUMBER:
<br /> P-0003
<br />
|