Laserfiche WebLink
PLUMBING PLUMBING <br /> SECTION 221316-SANITARY WASTE AND VENT PIPING SECTION 221319-SANITARY WASTE PIPING SPECIALTIES <br /> 1.1 PROJECT CONDITIONS 1.1 ACTION SUBMITTALS �• <br /> A. INTERRUPTION OF EXISTING SANITARY WASTE SERVICE: DO NOT INTERRUPT A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE RATED <br /> SERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTED CAPACITIES, OPERATING CHARACTERISTICS,AND ACCESSORIES FOR THE <br /> UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO FOLLOWING: <br /> PROVIDE TEMPORARY SERVICE ACCORDING TO REQUIREMENTS INDICATED: 1. FOG DISPOSAL SYSTEMS. <br /> 1. NOTIFY CONSTRUCTION MANAGER NO FEWER THAN TWO DAYS IN ADVANCE OF 2. GREASE INTERCEPTORS. <br /> PROPOSED INTERRUPTION OF SANITARY WASTE SERVICE. 3. GREASE REMOVAL DEVICES. <br /> 2. DO NOT PROCEED WITH INTERRUPTION OF SANITARY WASTE SERVICE WITHOUT 4. WIRING DIAGRAMS: POWER, SIGNAL,AND CONTROL WIRING. <br /> CONSTRUCTION MANAGER'S WRITTEN PERMISSION. <br /> 1.2 QUALITY ASSURANCE ©2011 STARBUCKS COFFEE COMPANY <br /> 1.2 MATERIALS A. QUALITY STANDARD FOR BELOW GRADE PLASTIC PIPING: NSF 14. <br /> A. HUB-AND-SPIGOT, SERVICE-CLASS, CAST-IRON SOIL PIPE AND FITTINGS BELOW <br /> GRADE WHERE REQUIRED BY LOCAL CODE. 1.3 PRODUCTS STARBUCKS COFFEE <br /> B. HUBLESS, CAST-IRON SOIL PIPE AND CISPI, CAST-IRON OR HUBLESS PIPING A. BACKWATER VALVES: HORIZONTAL-CAST IRON, DRAIN OUTLET OR HORIZONTAL- <br /> COUPLINGS. PLASTIC COMPANY <br /> C. SOLID-WALL ORCELLULAR-CORE SCHEDULE 40 ABS PIPE WITH ABS SOCKET B. CLEANOUTS: 2401 UTAH AVENUE SOUTH <br /> FITTINGS MAY BE USED ABOVE AND BELOW GRADE IF ALLOWED BY LOCAL CODE. 1. EXPOSED: COUNTERSUNK, COUNTERSUNK OR RAISED-HEAD, RAISED-HEAD, <br /> D. SHIELDED, NONPRESSURE OR PRESSURE BRASS,CAST-IRON OR PLASTIC CLOSURE PLUG. SEATTLE, WASHINGTON 98134 <br /> TRANSITION COUPLINGS. 2. CERAMIC TILE AND CARPETED FLOORS: SQUARE,ADJUSTABLE WITH NICKEL (206) 318-1575 <br /> E. UNION, FLANGE, FLANGE INSULATING KIT OR NIPPLE DIELECTRIC FITTINGS. BRONZE TOP. <br /> F. PE-FILM ENCASEMENT FOR UNDERGROUND METAL PIPING. 3. RESILIENT(VINYL)FLOOR: SQUARE,ADJUSTABLE, NICKEL BRONZE TOP WITH THESE DRAWINGS AND SPECIFICATIONS ARE <br /> G. SCHEDULE 40 PVC PIPE WITH PVC SOCKET FITTING MAY BE USED BELOW GRADE COMPATIBLE FLANGE. CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> IF ALLOWED BY LOCAL AUTHORITY. 4. WALL: ROUND, DEEP-CHROME-PLATED BRONZE,FLAT, CHROME-PLATED PROPERTY OF STARBUCKS CORPORATION, <br /> BRASS OR STAINLESS-STEEL COVER PLATE WITH ROUND, CHROME PLATED, WHICH IS THE OWNER OF THE COPYRIGHT IN THIS <br /> 1.3 ADHESIVES SCREW WALL ACCESS. WORK. THEY SHALL NOT BE REPRODUCED(IN <br /> A. ADHESIVES SHALL NOT EXCEED A VOC CONTENT OF 51OG/L FOR PVC AND 325 C. FLOOR DRAINS: WHOLE OR IN PART),SHARED WITH THIRD <br /> G/L FOR ABS. 1. CAST-IRON FLOOR DRAINS, WITH STRAINER, BODY STYLE AND OPTIONS AS PARTIES OR USED IN ANY MANNER ON OTHER <br /> SPECIFIED IN PLUMBING SCHEDULE. PROJECTS OR EXTENSIONS TO THIS PROJECT <br /> END OF SECTION 221316 2. PROVIDE TRAP PRIMER CONNECTIONS WHERE NEEDED PER CODE AND DESIGN WITHOUT THE PRIOR WRITTEN CONSENT OF <br /> REQUIREMENTS. STARBUCKS CORPORATION. THESE DRAWINGS <br /> D. TRENCH DRAINS TO BE AS SPECIFIED IN PLUMBING SCHEDULE. AND SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> E. THROUGH-PENETRATION FIRESTOP ASSEMBLIES: LISTED AND LABELED ASSEMBLY DESIGN INTENT FOR A PROTOTYPICAL <br /> OF SLEEVE AND STACK FITTING WITH FIRESTOPPING PLUG;WITH SPECIAL STARBUCKS STORE(WHICH IS SUBJECT TO <br /> CORROSION-RESISTANT COATING ON INTERIOR OF FITTINGS. CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> F. MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES: ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL <br /> 1. OPEN DRAINS, SHOP OR FIELD FABRICATE FROM SERVICE CLASS, HAVE ANY OBLIGATION NOR LIABILITY TO THE <br /> HUB-AND-SPIGOT, CAST-IRON, SOIL-PIPE FITTINGS. OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> 2. CAST-IRON OR BRONZE DEEP-SEAL TRAPS. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> BOTH PARTIES. <br /> 3. FLOOR-DRAIN,TRAP-SEAL PRIMER FITTINGS. <br /> 4. AIR-GAP FITTINGS. <br /> 5. COUNTERFLASHING-TYPE, CAST-IRON STACK FLASHING FITTINGS. ARCHITECT OF RECORD <br /> 6. CAST-IRON BODY VENT CAPS. 0 -0 t <br /> 7. FROST-RESISTANT VENT TERMINALS. o Eg == s. <br /> 8. EXPANSION JOINTS. a � o <br /> r <br /> UZ U <br /> 1.4 MANUFACTURED UNITS U, <br /> A. FOG DISPOSAL SYSTEMS AS SPECIFIED IN PLUMBING SCHEDULE. <br /> B. GREASE INTERCEPTORS AS SPECIFIED IN PLUMBING SCHEDULE. 4 <br /> C. GREASE REMOVAL DEVICES AS SPECIFIED IN PLUMBING SCHEDULE. mcg a r c h i t e c u r e <br /> D. SOLIDS INTERCEPTORS: FACTORY-FABRICATED INTERCEPTOR MADE FOR <br /> REMOVING AND RETAINING LINT OR SEDIMENT FROM 111 Pacifica,Suite 280,Irvine,CA 92618 <br /> WASTEWATER AS SPECIFIED IN PLUMBING SCHEDULE. P:949.553.1117 F:949.474.7056 <br /> END OF SECTION 221319 <br /> ACIES :OQRaFE.....• <br /> :. PN G.R f le;' <br /> PLUMBING ENGINEERING �o� ��': <br /> 3371 Olcott Street z <br /> SECTION 223000-DOMESTIC-WATER HEATERS Santa Clara,CA 95054 No. 4 ; <br /> 1.1 QUALITY ASSURANCE ph:(408)522-5255 fin �c <br /> fx:(408)522-5260 •:sT QFC Gp �Q:• <br /> A. PERFORMANCE EFFICIENCY:ASHRAE/IESNA 90.1 AND ASHRAE 90.2. info@acies.net •• ql HAND <br /> B. ASME COMPLIANCE:ASME BOILER AND PRESSURE VESSEL CODE: SECTION VIII, Copyright©2019 ••' ..• <br /> DIVISION 1. ••••• <br /> C. NSF COMPLIANCE: NSF 61 ANNEX G, "DRINKING WATER SYSTEM COMPONENTS- <br /> HEALTH EFFECTS." <br /> 1.2 COMMERCIAL, ELECTRIC, DOMESTIC-WATER HEATERS <br /> A. COMMERCIAL, LIGHT-DUTY, STORAGE, ELECTRIC, DOMESTIC-WATER HEATERS: <br /> STEEL, GLASS LINED,VERTICAL ARRANGEMENT WITH 150-PSIG(1035-KPA) <br /> PRESSURE RATING. <br /> B. SEE PLUMBING SCHEDULE FOR MAKE, MODEL, CAPACITY, AND RECOVERY RATE. <br /> 1.3 COMMERCIAL, GAS-FIRED, STORAGE, DOMESTIC-WATER HEATERS <br /> A. COMMERCIAL,ATMOSPHERIC], POWER-BURNER OR POWER-VENT, GAS-FIRED, <br /> STORAGE, DOMESTIC-WATER HEATERS: STEEL, GLASS LINED, VERTICAL <br /> ARRANGEMENT WITH 150-PSIG(1035-KPA)PRESSURE RATING CONDENSING TYPE. O <br /> MINIMUM EFFICIENCY 90%. MEETS LOW NOx EMMISIONS PER CODE <br /> REQUIREMENTS. �JJ <br /> ' ) N <br /> 1.4 DOMESTIC-WATER HEATER ACCESSORIES L0 <br /> I <br /> A. DRAIN PANS: CORROSION-RESISTANT METAL WITH RAISED EDGE. LLI <br /> B. PIPING-TYPE HEAT TRAPS. 3: z Q <br /> C. HEAT-TRAP FITTINGS. Q U <br /> D. GAS SHUTOFF VALVES. w _I <br /> E. GAS PRESSURE REGULATORS: PRESSURE RATING TO MATCH GAS SUPPLY <br /> F. AUTOMATIC GAS VALVES. W z <br /> G. PRESSURE-REDUCING VALVES. 2i <br /> (/)w <br /> H. COMBINATION TEMPERATURE-AND-PRESSURE RELIEF VALVES. Z Q <br /> I. PRESSURE RELIEF VALVES. <br /> J. VACUUM RELIEF VALVES. l_ V <br /> K. SHOCK ABSORBERS. w N LU O <br /> L. DOMESTIC-WATER HEATER STANDS. <br /> M. DOMESTIC-WATER HEATER MOUNTING BRACKETS. O O <br /> N. EXPANSION TANK 0 S � C) <br /> 1.5 ALL COMPONENTS OF DOMESTIC WATER SYSTEM TOUCHING DOMESTIC WATER ARE G <br /> LEAD FREE, INCLUDING ALL VALVES AND FITTINGS. STORE #: 13402 <br /> END OF SECTION 223000 PROJECT #: 39714-051 <br /> CASEWORK CONCEPT: CORE <br /> ISSUE DATE: <br /> PROGRAM MANAGER: M. DREBIKA <br /> STORE DESIGNER: S. BELVINS <br /> LEED®AP: N/A <br /> CHECKED BY: <br /> ACIES PROJECT#: 190480 <br /> ACIES DESIGNER BY: LL <br /> ACIES CHECKED BY: MP <br /> Revision Schedule <br /> Rev Date By Description <br /> SHEET TITLE: <br /> PLUMBING OUTLINE <br /> SPECIFICATIONS <br /> SCALE:AS SHOWN N.T.S. <br /> SHEET NUMBER: <br /> P-0003 <br />