Laserfiche WebLink
MONITORING AND REPOR ING PROGRAM <br /> TRI VALLEY GROWERS, ILANT NO. 4 <br /> SAN JOAQUIN COUNTY <br /> Constituents Units Station Sampling Frequency <br /> Dissolved Oxygen mg/1 R-1, R-2 Weekly <br /> pH pH Units R-1, R-2. Daily <br /> Turbidity Turbidity Units R-1, R-2 Weekly <br /> Temperature 0 R-1, R-2 Daily <br /> In conducting the receiving water sampling, a log should be kept of the receiving <br /> water conditions thr ughout the reach bounded by Stations R-1 and R-2. Attention <br /> should be given to the presence or absence of: <br /> a. Floating or suspended matter <br /> b. . Discoloration <br /> C. Bottom deposits <br /> d. Aquatic Life <br /> Notes on receiving water conditions shall be summarized in the monitoring report. <br /> WATER SUPPLY MONITORING <br /> A sampling station shall be established where a representative sample of the water <br /> supply can be obtained. The following shall constitute the water supply monitoring <br /> program: . <br /> Constituent Units Sampling Frequency <br /> Standard Minerals mg/l Yearly at same time <br /> as effluent samples <br /> Specific Conductivity Micromhos/em Monthly during period <br /> @250C of discharge <br /> Total Dissolved Solids mg/l Monthly during period <br /> of discharge <br /> REPORTING <br /> In reporting the monitoring data, the discharger shall arrange the data in tabular form <br /> so that the date, the constituents, and the concentrations are readily discernible. <br /> The data shall be summarized in such a manner to illustrate clearly the compliance with <br /> waste discharge requirements. <br /> 2 _ <br />