Laserfiche WebLink
I <br />' Quarterly Monitoring Report January 1999 <br /> Canepa s Car Wash(Pari.Street) <br /> February 8 1999 <br />' Page 4 <br /> the results of the analyses are included in Appendix C Historical groundwater analyses are presented in Table <br /> A, Appendix B <br /> TABLE 2 <br /> LABORA TORY ANALYTICAL RESULTS (JANUARY 1999) <br />' Other <br /> B T E X MTBE Oxygenates/ TPH-G <br /> Additives <br />' MONITOR Detection 03 03 03 06 10 10- 10 0 O5 <br /> WELL/ DA 1 E Limits ug/] µg/1 µg/1 µg/1 µg/1 µg/1 tng/l <br /> SAMPLE Sample I D <br />' MW-1 1/20199 2038-MW1-1/20199 ND 06 ND ND ND ND 007 <br /> MW-2 1/20199 2038-MW2-1/20/99 280 160 370 500 ND ND 84 <br />' MW-3 1/20199 2038-MW3-1/20/99 05 46 06 06 54 ND 03 <br /> MW-4 1/20199 2038-MW4-1/20/99 ND ND ND ND ND ND ND <br />' MW-5 1/20199 20')8-MW5-1/20/99 2000 2,200 600 1200 ND ND 12 <br /> MW-6 1/20199 2038-MW6-1/20/99 16 13 03 ND 13 ND ND <br /> MW-7 1/20/99 2038-MW7-1/20/99 04 18 ND ND ND ND 01 <br /> Unit Com r,rsions Analytical <br />' µgfl parts per billion(ppb) B T E X=benzene,toluene,ethyl benzene and total avlenes <br /> mg/1 parts per million(ppm) TPH-G=total petroleum hydrocarbons,qu inttfied as gasoline <br /> MTBE=Methyl tertiary Butyl Ether <br /> Other Oxygenates/Additives=ethanol,Di-isopropyl ether(DIPS),Ethyl tertiary-Butyl Ether <br />' (ETBE) tertiary amyl Methyl Ether(TAMF),and tertiary-Butanol <br /> ND=none detected at or above reported laboratory detection limit <br /> I5 DISCUSSION OF RESULTS <br /> Since Septeniber, 1994, the depth to groundwater at the site has generally decreased from approximately 46 to <br />' 24 feet bgs The average depth to groundwater measured during the January 1999, groundwater monitoring <br /> eveint was approximately 24 1 feet below the monitor well measuring points The groundwater elevation <br /> ranged from 12 20 to 13 88 feet bmsl The groundwater elevation contour map (Figure 3, Appendix A) <br />' indicates that the groundwater gradient at the site Is generally towards the northeast This Is consistent with <br /> previous monitoring results A hydrograph of monitor wells MWA through MW-7 (Figure 4, Appendix A) <br /> illustrates the fluctuation of the groundwater table Historical groundwater measurements are provided in the <br />' accompanying Hydrograph Table (Appendix A) <br /> The laboratory analytical results for the January 1999, groundwater monitoring event are generally consistent <br />' with the laboratory analytical results for the Octobei 1998 gloundwatcr monitoring event None of the <br /> analytes of concern were detected in the groundwater sample collected from monitor well MW-4 TPH-G and <br /> all BTEX constituents were detected In the samples collected from MW-2, MW-3, and MW-5 Low <br /> concentrations of toluene and TPH-G were detected in the groundwater sample collected fiom MW- Low <br />' �J CONDOR <br />