Laserfiche WebLink
i <br /> 12 May 2005 <br /> AGE-NC Project No 96-0229 <br /> Page 2 of 6 <br />' On 08 December 2004, approximately 3 to 9 gallons of ground water(a minimum of three casing- <br /> water volumes per well) were evacuated (purged) from wells MW-3 through MW-12 utilizing <br /> disposable bailers Approximately 6 gallons and I'/2 gallons were removed from wells MW-1 and <br /> MW-2, respectively before the wells were purged dry Temperature, pH, and conductivity were <br /> measured for stabilization at regular purge-volume intervals from each well using an Oakton water <br /> analyzer Field data and logs are included in Appendix A Purged ground water was containerized <br /> in 55-gallon drums and stored on-site in an area lacking general public access <br /> Approximately 3/4 to 3 gallons of ground water(a minimum of three casing-water volumes per well) <br /> were purged from multi-level wells MW-13 (A-D), MW-14 (A-D), MW-15 (A-D), MW-16 (B-E), <br /> MW-17 (A-C) and MW-19(A-C), except for well MW-16A due to insufficient amount of water in <br /> the well and well MW-18 (A-E)due to a parked vehicle Each well was purged by lowering and <br />' raising a 3/8-inch outer diameter,length-discrete polyethylene hose equipped with a ball-valve water <br /> tip through the top chambers into the specific water-charged screened section A Waterra Hydro- <br /> Lift II pump equipped with a mechanical arm was utilized to surge each well with a polyethylene <br /> hose Temperature, pH, and conductivity were measured for stabilization at regular purge-volume <br /> intervals from each well using an Oakton water analyzer Field data and logs are included in <br /> Appendix A Purged groundwater was containerized in 55-gallon drums and stored on-site in an area <br /> lacking general public access <br />' 2 1 1 Ground Water Sampling <br /> Following well purging, the ground water level from each well was allowed to achieve a minimum <br /> of 80% recharge prior to sample collection Ground water samples were transferred into <br /> 40-milliliter (ml) EPA-approved volatile organic analysis (VOA) vials containing 0 5 ml 18% <br /> hydrochloric acid solution as a sample preservative Care was taken to ensure that visible air bubbles <br /> were not present in the vials after filling and capping Ground water sample containers were labeled <br /> with the well designation, date, time, and sampler's initials <br /> 2 12 Laboratory Analysis Of Ground Water Samples <br /> Each ground water sample was logged on a chain of custody form,placed in a chilled container,and <br /> transported to a California Department of Health Services (DHS)-certified laboratory for analysis <br /> for <br /> Total petroleum hydrocarbons quantified as gasoline (TPH-g) by EPA Method <br /> SW5030/8015M, <br /> • • Benzene, toluene, ethylbenzene, and xylenes (BTEX) by EPA Method 8260B, and <br />■ Advanced GeoEnvironmental,Inc <br />