Laserfiche WebLink
TABLE 7 <br /> FLOW RATES AND ANALYTICAL RESULTS <br /> OF AIR SAMPLE ANALYSES-UNIT 2(SL NO 9230) <br /> ARCO Facility No 6100 <br /> 25775 South Patterson Pass Road <br /> Tracy,California <br /> Date Flowrate Influent Sample Analyses(m m') <br /> (scfm)t (acfin) Tem (°F) ID GRO Benzene Toluene Ethylbenzene Xylenes MTBE <br /> 10/06/04 235 55 21443 120 6100TINF2 4,700 A 110 A 120 A l I A 71 A <0 50 A <br /> 6100CiNF2 1,600 A 41 A 39 A 3 6 A 21 A <0 50 A <br /> 6100EFF210604 57 A <0 50 A <0 50 A <0 50 A <0 50 A <0 50 A <br /> 10/14/04 29266 24669 145 6100INF2101404 2,000[2,5] A 44[2,5] A 48[2,5] A 5 8[2,5] A 30[2,5] A <2 5[2,5] A <br /> 6100EFF2101404 <50[4] A <0 50[4] A <0 50[4] A <0 50[4] A <1 0[4] A <0 50[4) A <br /> 11/04/04 217 15 20293 105 6100AINF-110404 3,200 A 110 A 94 A 63 A 34 A <0 50 A <br /> 6100ASYSINF-110404 1,000 A 34 A 30 A 2 3 A 12 A <050 A <br /> 6100AEFF-110404 160 A 4 3 A <0 50 A <012 A <012 A <0 14 A <br /> 11/11/04 12366 112 19 122 610OClNF2111104 2,200 A 38 A 33 A <50 A 9 5 A <5 0 A <br /> 6100£FF2111104 <50 A <0 50 A <0 50 A <050 A <0 50 A <0 50 A <br /> GRO=Gasoline Range Organics(C4-C12) <br /> MTBE=Methyl tertiary bury]ether <br /> WC=inches of water column <br /> mg/m'=milligrams per cubic meter <br /> Temp =Temperature in degree Fahrenheit <br /> Standard flow rate(scrm)measured using standard calibrated devices is converted to actual flow rate(acfm)using the following formulas QAIQC Review <br /> Pressure corrected influent flow rate Total influent air flow rate sefm* ((406 8'WC "WC)/406 8 WC) A=Data accepted without qualification <br /> Temperature Corrected influent flow rate Pressure corrected flow rate *((464 R+68deg F)1(deg F+460 R)) ]=Data accepted with qualification <br /> *=Average vacuum R=Data rejected <br /> i Field data sheets record flow rate(inches of water column,units)into the SVE system using a differential pressure guage and pitot tube <br /> These readings were converted to flowrate(acfm,units)in 2 inch diameter pipe <br /> [l]Primary and confirmation results varied by greater than 40%Relative Percent Difference(RPD) <br /> [2]Reporting limits.were raised due to high level of analyte present in the sample <br /> [3]The reported result for GRO is due to chromatographic peals present in the gasoline quantitation range however the peaks present do not resemble the pattern for gasoline <br /> [4]Extracted out of holding time <br /> [5]The elevated reporting limits were the result of dilutions performed by the laboratory in order to quantitate a target analyte <br /> ARCO 6ioo_0&M Page 2 of 2TUS <br />