SVE QUARTERLY OPERATION AND PERFORMANCE <br /> Equipment Inventory Two 200 cfm King, Buck & Associates SVE <br /> Systems[SL Nos 9321(Unit 1)&9230(Unit 2 <br /> Extraction Wells VW-6, VW-8, VW-9, & MW-9 connected to Unit 1 <br /> (currently) <br /> VW-1, VW-14, MW-3, & MW-7 connected to Unit 2 <br /> currents <br /> Operating Mode Catalytic _ <br /> Required Permits San Joaquin Valley Air Pollution Control District <br /> Permit Nos N-5026-1-0& N-5026-2-0 <br /> GRO Cone End of Period [Unit 11 7,600 mg/m3 (total influent) <br /> GRO Cone End of Period [Unit 2] 6,400 Me/M3 total influent <br /> Benzene Cone End of Period (Unit 1] _ 110 mg/m3(total influent) <br /> Benzene Cone End of Period [Unit 21 100 mg/m3 total influent <br /> MTBE Cone End of Period [Unit 1] <5 0 m Im3 total influent <br /> MTBE Cone End of Period [Unit 2] <5 0 mg/m3(total influent) _ <br /> Average Flow Rate This Period [Unit 1] 176 42 scfm <br /> Average Flow Rate This Period [Unit 2] 262 98 scfm <br /> Applied Vacuum This Period [Unit 1] 10 inches water column <br /> • Applied Vacuum This Period [Unit 2] 10 inches water column <br /> FIC Destroyed This Period (tab) 5,284 56 lbs as GRO from both units <br /> Cumulative FIC Destroyed 8,623 lbs as GRO from both units <br /> Number of Auto Shutdowns 1 (each Unit) _ <br /> DISCUSSION <br /> Upper Water Bearing Zone end Zone 1 <br /> During the site visit conducted on September 6, 2004, free product was measured in well VW-4 at a <br /> thickness of 0 08 feet Approximately 2 gallons of product/water mixture was manually balled on <br /> September 6, 2004, and stored in a properly labeled DOT approved drum pending disposal <br /> Approximately 12 gallons of productlwater mixture has been manually balled to date Product thickness <br /> measurements and volumes of liquid balled are summarized in Table 1 <br /> At the time of the third quarter 2004 monitoring event, groundwater levels had decreased between 0 04 <br /> and 5 01 feet in wells MW-2, MW-13, VW-1, VW-3, and VW-4 since the previous monitoring event (June <br /> 21, 2004) Depth-to-water measurements were normalized to mean sea level (MSL) and used to <br /> construct a groundwater elevation contour map (Figure 3) Wells that contained less than 1 foot of water <br /> are interpreted to be dry and are indicated as "dry" on Figure 3 Because wells VW-1 and VW-6 are <br /> screened in a shallower interval than wells VW-2, VW-4, MW-2, and MW-13, these two wells were not <br /> used in contouring Groundwater flow was to the south-southeast at a gradient of 0 071 ft/ft <br /> Groundwater flow in the upper water bearing zone has been to the south-southeast and toward the <br /> southwest during previous quarters <br /> . GRO, benzene, and MTBE were reported in wells VW-1 and VW-3 GRO and benzene were also <br /> reported in wells MW-13 and VW-6 The highest concentrations of GRO (120,000 µgll_), benzene (32,000 <br /> P IBp-Arco for URS\6I001Quarteriy120041Arco_6100_3QO4 doc STRATUS <br />