Laserfiche WebLink
Table I <br /> Source Test Summary <br /> ARCO Service Station No 6100 <br /> 25775 South Patterson Pass Road <br /> Tracy, California <br /> System Influent Concentrations,mg/rn3 5/16/2005 <br /> Gasoline Range Organics 22,000 <br /> Benzene 120 <br /> Toluene 120 <br /> Ethylbenzene <100 <br /> Total xylenes 110 <br /> MTBE <100 <br /> Effluent Concentrations, mg/m3 5/16/2005 <br /> Gasoline Range Organics <50 <br /> Benzene <0 50 <br /> Toluene <0 50 <br /> Ethyl benzene <0 50 <br /> Total xylenes <0 50 <br /> MTBE <0 50 <br /> Destruction Efficiencies, % 5/16/2005 <br /> Gasoline Range Organics X99 6% <br /> Benzene X99 5% <br /> . MTBE X99 4% <br /> Estimated Discharge, lbs/day 5/16/2005 <br /> Gasoline Range Organics <1 37 <br /> Benzene <0 01 <br /> MTBE <0 01 <br /> System Influent Flowratei (acfm) 191 89 <br /> Applied Vacuum("WC) 19040 <br /> mg/m3 = milligrams per cubic meter <br /> lbs/day = pounds per day <br /> acfm = actual cubic feet per minute <br /> "WC = inches water column <br /> GRO=Gasoline Range Organics <br /> BTEX=Benzene,Toluene, Ethylbenzene,and Total Xylenes <br /> MTBE—Methyl Tertiary Butyl Ether <br /> =Field data sheets record flow rate("WC, units) into the SVE system using a differential <br /> pressure guage These readings were converted to flowrate(acfm, units)in 4-mch pipe <br /> Note Detailed calculations are presented in Appendix C <br /> GRO analyzed by EPA Method 8015B,and BTEX&MTBE analyzed by EPA Method 8260B <br /> ARCO 6100 Source Test Calcs& Summary_May 2005 <br />