y l..mepa's Car Wash (Pacific Avenue) <br /> 1 Problem Assessment Report and Corrective Action Plan <br /> Page 6 <br /> Only one sample from either SB-3 or SB-4 contained a constituent of concern (MTBE at 0.28 mg/kg from <br /> 40 feet has in SB-4) . These borings were installed following the intermittent operation and shut down of <br /> the SVE system . MTBE (MW- 1 I , 0 . 005 mg/kg at 35 feet and 0 . 009 mg/kg at 40 feet) was the only <br /> constituent of concern found in soil samples collected from borings for monitor wells MW-9. MW- 10, <br /> and MW- 11 . <br /> The mass of petroleum hydrocarbon in the soil and the volume of contaminated soil were estimated using <br /> the exploratory data provided by WHF in 1994 . The estimated concentrations and distributions of <br /> hydrocarbons in soil are illustrated in plan view in Figure 7. The mass and volumes were estimated using <br /> the software "HyperVentilate 2. 0". The average soil TPH-G concentrations quantified in mg/kg were <br /> applied to a range of soil volumes to estimate the mass balance . The soil volumes were estimated based <br /> on the approximate thickness and radius of the contaminated soil column . The volume of petroleum <br /> hydrocarbons was estimated at approximately 13,000 pounds or 2,050 gallons (6.34 lbs/gal.). The <br /> volume of contaminated soil containing greater than 10 mg/kg TPII-G was estimated at 18,000 cubic <br /> yards. <br /> An array of nine soil vapor extraction wells was installed under the dispenser island in 1993 , and an SVE <br /> and combustion system was installed to remove VOCs from the extracted soil gas. The combustion unit <br /> was permitted in March 1994 and operated to mid-June 1995 . Average influent VOC concentrations <br /> measured with a photo ionization detector exceeded 2,200 ppm. The last influent measurement collected <br /> from the system was 2, 145 ppm in May 1995 . Operation of the system in 1995 configuration was halted <br /> in the fall of 1996 . A new thermal oxidation unit was installed, and the system was restarted in March <br /> 1999 and operated intermittently until February 2001 . From March 1999 to June 1999, an estimated 3 ,085 <br /> pounds of hydrocarbons were extracted from the soil and groundwater. Selected VOC concentrations in <br /> air influent to the thermal oxidation system on March 15, 1999 were 200 µg/l benzene and 190 µg/1 <br /> MTBE. <br /> In March 2002, the SVE was modified to use vapor phase activated carbon. Selected influent soil vapor <br /> VOC concentrations in March 2002 were 0 . 75 µg/1 benzene and < 0 . 15 µg/I MTBE. Depth to <br /> groundwater in the SVE wells was approximately 43 feet in March 1996 and 33 feet in April 2002 . <br /> Clearly, the soils contaminated with petroleum hydrocarbons are saturated and are now below the water <br /> table. The VOCs extracted by the system in 2002 are mostly vapors released from groundwater. <br /> 5.2 DISTRIBUTION OF GROUNDWATER CONTAMINATION <br /> Groundwater monitor wells were installed to investigate the vertical and lateral distribution of VOCs in <br /> groundwater beneath and adjacent to the site. The evolution and migration of the groundwater plume have <br /> been difficult to monitor because of rising water levels. Monitor wells MW-1 through MW-4, installed in <br /> 1993 , were fitted with screens extending from depths of 50 feet to 70 feet. Monitor well MW-5 was <br /> constructed in 1994 with the same screen position, and monitor wells MW-6, MW-7, and MW-8, also <br /> constructed in 1994, were constructed with screens extending from 45 feet to 65 feet. By March 1994, <br /> the rising water table approached the top of the screens in monitor wells MW- 1 through MW-5 . In 2001 , <br /> Condor installed monitor wells MW-9, MW- 10 and MW- 11 with screens positioned across the present <br /> water table elevation, a depth of approximately 35 feet. A deep monitor well, MW- 12d, screened from <br /> 100 to 110 feet, and nine hydropunch borings also were installed in 2001 to investigate the vertical extent <br /> of the plume and to sample a vertical sequence through the plume near the source area and in areas of <br /> potential lateral extent. <br /> 4M <br /> #L4 CONDOR <br />