Laserfiche WebLink
1 <br />' REPORT <br /> . QUARTERLY GROUNDWATER MONITORING <br />' THIRD QUARTER—JULY 2000 <br /> Canepa's Car Wash <br />' 6230 Pacific Avenue <br /> Stockton California <br /> INovember 8, 2000 <br /> 1..0 INTRODUCTION <br /> Condor Earth Technologies, Inc (Condor) conducted quarterly groundwater monitoring on July 10 and <br /> 11, 2000, at the Canepa's Car Wash facility located at 6230 Pacific Avenue in Stockton, California <br />' (Figure 1, Appendix A) This report was prepared by Condor at the request of the property owner, Mr <br /> Remo Canepa <br /> The scope-of-work performed during the quarterly groundwater monitoring event is described in <br /> Condor's Proposal for Site Evaluation and Groundwater Monitoring (April 8, 1996) The scope-of-work <br /> presented in the proposal was approved by Mr Ronald Rowe of the San Joaquin County Public Health <br /> • Services, Environmental Health Division (PHS/EHD) The PHS/EHD subsequently modified the <br /> approved scope-of-work to include gasoline oxygenates/additives analyses of the site groundwater <br /> samples This report includes site background information, a description of the fieldwork and laboratory <br /> analyses performed for the July 2000 quarterly groundwater monitoring event, discussion of results, and <br /> recommendations <br /> 2.0 SITE BACKGROUND <br /> tCanepa's Car Wash consists of an automated car washing facility, a fuel station, and a convenience store <br /> (Figure 2, Appendix A) The car wash and fuel station have been in operation for more than two decades <br /> In the spring of 1993, three underground storage tanks (USTs), fuel lines and dispensers were removed <br /> and replaced with a double walled system The former USTs consisted of two 12,000-gallon gasoline <br />' USTs and one 5,000-gallon diesel UST Upon removal of the USTs and piping, it was discovered that the <br /> fuel lines had leaked and that the USTs had been overfilled Approximately 600 cubic yards of soil were <br /> removed from the UST excavation area <br /> IBeginning in March 1993, one soil boring and a network of nine soil vapor extraction (SVE) wells were <br /> drilled and installed in the area of the fuel dispenser islands Between September 1993 and March 1994, <br /> eight monitoring wells (MW-1 through MW-8) were installed In March, 1994, a soil vapor extraction <br /> system was installed and operated In the Fall of 1996, it was determined that the SVE system was <br /> inadequate and operation of the system was terminated A second SVE system was later installed and <br /> began operation on March 15, 1999 <br /> Condor has conducted quarterly groundwater monitoring activities at the site since August 1996 Analyses <br /> of groundwater samples collected from the SVE wells (SVE-1 through 9) indicate that high concentrations <br /> of benzene, toluene, ethyl benzene, and total xylenes (BTEX), total petroleum hydrocarbons quantified as <br /> �.� caNnors <br />