Laserfiche WebLink
. SITE HISTORY <br /> CANEPA'S CAR WASH <br /> 6230 Pacific Ave. <br /> Stockton, CA <br /> Canepa's Car Wash consists of an automated car washing facility, a fuel station and a convenience store. <br /> The site is located at 6230 Pacific Avenue, in Stockton, California. The car wash and fuel station has been <br /> in operation for over two decades. <br /> Between February 25 and.March 3, 1993, three underground storage tanks (USTs), fuel lines and dispensers <br /> were removed by WHF Environmental (WHF) and replaced with a doubled walled system. The USTs <br /> consisted of two 12,000-gallon gasoline USTs and one 5,000-gallon diesel UST. As reported by WHF, <br /> upon removal of the tanks and piping, it was discovered that the fuel lines had leaked and that the USTs had <br /> been overfilled. Approximately 600 cubic yards of soil were removed from the UST excavation area. The <br /> excavated soil was subsequently characterized and disposed of at Forward Landfill in Manteca, California. <br /> At least 16 soil samples were collected from the tank excavation for laboratory analyses. The laboratory <br /> results indicated predominantly low TPH-G (gasoline at <15 mg/kg) and low BTEX concentrations. One <br /> (1)soil sample collected from the northeastern sidewall of the tank excavation contained 773 mg/kg TPH-G <br /> and BTEX concentrations up to 170,000 mg/kg (total xylenes). TPH-D (diesel) was detected in one soil <br /> sample at 32 mg/kg. At least seven soil samples were collected from beneath the former fuel dispenser <br /> islands for laboratory analyses. Elevated concentrations of TPH-G (up to 3,800 mg/kg) and BTEX <br /> concentrations ranging from 26 mg/kg to 560,000 mg/kg were detected in the fuel dispenser soil samples. <br /> TPH-D (diesel) was not detected at or above the laboratory reported detection limit in the soil samples <br /> collected from beneath the former fuel dispenser islands_ <br /> On March 12, 1993, soil boring (B-1)was installed by WHF immediately east of the former fuel dispenser <br /> islands. Groundwater was encountered at approximately 56 feet below the ground surface (bgs). Moderate <br /> to strong petroleum odors were detected from 15 feet bgs to 56.5 feet bgs. Elevated TPH-G and BTEX <br /> concentrations were detected in soil samples collected from 35 feet bgs to 56.5 feet bgs. <br /> Following the soil boring installation, a network of nine SVE wells were drilled and installed in the area of <br /> the fuel dispenser islands. According to the former consultant, William H. Fox of WHF, the SVE wells <br /> were installed without compiling geological logs and without the collection of laboratory samples as agreed <br /> upon by the PHS/EHD, due to time constraints. Mr. Fox indicated that based on field observations, all of <br /> the SVE wells showed signs of gasoline contamination during installation. An internal combustion unit <br /> (ICU)was installed at the site for vapor extraction and treatment under the Authority to Construct issued by <br /> the San Joaquin Valley Unified Air Pollution Control District (APCD), dated October 7, 1993. The ICU <br /> was started on March 11, 1994, and operated through June 10, 1995. Based on field monitoring notes <br /> prGVidcd by WiT, average influent organic vapor concentrations, mcasurcd with a photo ionization <br /> detector(PID), exceeded 2,200 parts per million (ppm). The last influent measurement collected from the <br /> system was 2,145 ppm (May 15, 1995). <br /> Between September 28 and 30, 1993, WHF installed four(4) monitoring wells (MW-1 through MW-4) at <br /> the site. Low to elevated concentrations of gasoline were detected in groundwater samples collected from <br /> MW-1 through MW-4. Field observations indicated moderate to strong gasoline odors in the soil at MW-1 <br /> from 20 feet to 55 feet bgs and at MW-2 from 40 feet to 67 feet bgs. Soil samples collected from MW-1 <br /> and MW-2 were not analyzed in the laboratory. Analyses of soil analyses of samples collected from MW-3 <br /> and MW-4 indicated that TPH-G or BTEX were not detected at or above the laboratory reported detection <br />