Laserfiche WebLink
1 <br /> TABLE A (Continued) <br />' Constituent R T E x MIRE TPH-G <br /> EPA Method (602) (602) (602) (602) (602) (5030) <br />' Detection Limits 03 03 03 06 10 005 <br /> ltd µg/I µg/l lid Ng/l mgll <br />' MW-7 6117/94 MW-7 2200 282 ND 100* 286 NA 79 <br /> 12/8/94 MW-7 2000 22 11 18 NA 2 1 <br /> 3/16195 MW-7 300 077 ND 1 9 NA 047 <br />' 6/12/95 MW-7 860 091 090 097 NA 083 <br /> 8/1/96 MW-7 ND ND 30 ND ND ND <br /> 10/21/96 MW-7 ND ND 5 8 ND ND ND <br /> 1116197 MW-7 ND ND 36 ND ND ND <br /> 411197 MW-7 ND ND ND ND ND ND <br /> MW-8 6/17194 MW-8 390 06 ND 0 5 ND 0 5 NA 009 <br /> 1218194 MW-8 ND ND ND ND NA 0 063 <br /> 3116195 MW-8 054 047 ND ND NA ND <br /> 6/12195 MW-8 23 16 ND 081 NA ND <br /> 811/96 MW-8 ND ND ND ND ND ND <br /> 10/21/96 MW-8 ND ND ND ND ND ND <br /> 1115/97 MW-8 ND ND NO ND ND ND <br /> 4/1/97 MW-8 ND ND ND ND ND ND <br /> SV-1 lllfl97 SV-1 41 000 17,000 3 300 6200 1 400 120 <br /> SV-7 8!1/96 SV-7 91,000 75 000 3 000 i8 000 7 800 360 <br /> SV-9 412197 SV-9 25 000 ND 1500* 2,300 1 900 79 000 53 <br /> Unit Conversions <br /> I µg11 parts per billion (ppb) B T E X =benzene,toluene ethyl benzene and xylene <br /> mg/l parts per million(ppm) TPH-G =total petroleum hydrocarbons, quantified as gasoline <br /> MTBE=methyl tertiary butyl ether <br /> ND=none detected at or above laboratory detection limit <br /> ND X=none detected to a level of X <br /> * =detection limit raised due to elevated petroleum hN drocarbon result <br /> NA =not tested for this analyte <br /> I ' <br />