Laserfiche WebLink
Table 9 <br /> Groundwater Monitoring Data and Analytical Results <br /> Former Unocal Service Station No 2859 <br /> 9665 Pacific Avenue <br /> Stockton, California <br /> EXPLANATIONS <br /> Groundwater monitonng data and laboratory analytical results prior to November 25,2003,were compiled from reports prepared by Gettler-Ryan, Inc <br />� TOC=Top of Casing <br /> B= Benzene (ug/L)=Micrograms per Liter <br /> (ft)= Feet T=Toluene ND=Not Detected <br /> DTW = Depth to Water E= Ethylbenzene (D)= Duplicate <br /> GWE=Groundwater Elevation X=Xylenes —=Not Measured/Not Analyzed <br /> (msl)= Mean sea level MtBE=Methyl tertiary butyl ether QA=Quality Assurance/Trip Blank <br /> TPHg =Total Petroleum Hydrocarbons as Gasoline EB= Equipment Blank <br /> TOC elevations have been surveyed relative to mean sea level On February 10,1999,TOC measurements were re-surveyed relative to City of Stockton BM#24, <br /> located in monument box at the northwest comer of Pacific Avenue and Harding Way, (Benchmark Elevation=9 71 feet, NGVD29) <br /> On June 31,2001,the following wells were surveyed MW4, MW-6 and MW-11 through MW-14 using the previous benchmark <br /> 1 Laboratory report indicates the hydrocarbons detected appeared to be a gasoline and non-gasoline mixture <br /> 2 Laboratory report indicates the hydrocarbons detected did not appear to be gasoline <br /> 3 Detection limit raised Refer to analytical reports <br /> 4 MTBE by EPA Method 8260 <br /> 5 Laboratory report indicates unidentified hydrocarbons C6-C12 <br /> 6 Laboratory report indicates gasoline and unidentified hydrocarbons>C8 <br /> 7 Well development only <br /> 8 Laboratory report indicates gasoline and unidentified hydrocarbons C6-C12 <br /> 9 Laboratory report indicates discrete peaks <br /> 14 Laboratory report indicates gasoline C6-C12 <br /> 11 Laboratory report indicates weathered gasoline C6-C12 <br /> 12 Laboratory report indicates hydrocarbon pattern is present in the requested fuel quantitation range, but does not resemble the pattern of the requested fuel <br /> 13 Laboratory report indicates the result was reported with a high bras due to the continuing calibration verification falling outside acceptance criteria <br /> 14 Laboratory report indicates gasoline C6-C10 <br /> 15 Laboratory report indicates discrete peak @ C7 <br /> 16 Current laboratory analytical results to not coincide with historical data,and although the laboratory results were confirmed,it appears that the samples were switched <br /> 17 Laboratory report indicates discrete peak @ non-target @13 RT <br /> 18 Laboratory report indicates discrete peak @ non-target @9 37 RT <br /> 06940-357 27 of 28 ENSR Corporation <br />